CVE-2022-30312 1 Honeywell 10 Trend Iq411, Trend Iq411 Firmware, Trend Iq412 and 7 more 2025-06-17 N/A 6.5 MEDIUM
The Trend Controls IC protocol through 2022-05-06 allows Cleartext Transmission of Sensitive Information. According to FSCT-2022-0050, there is a Trend Controls Inter-Controller (IC) protocol cleartext transmission of credentials issue. The affected components are characterized as: Inter-Controller (IC) protocol (57612/UDP). The potential impact is: Compromise of credentials. Several Trend Controls building automation controllers utilize the Inter-Controller (IC) protocol in for information exchange and automation purposes. This protocol offers authentication in the form of a 4-digit PIN in order to protect access to sensitive operations like strategy uploads and downloads as well as optional 0-30 character username and password protection for web page access protection. Both the PIN and usernames and passwords are transmitted in cleartext, allowing an attacker with passive interception capabilities to obtain these credentials. Credentials are transmitted in cleartext. An attacker who obtains Trend IC credentials can carry out sensitive engineering actions such as manipulating controller strategy or configuration settings. If the credentials in question are (re)used for other applications, their compromise could potentially facilitate lateral movement.
CVE-2025-2605 1 Honeywell 4 Mb-secure, Mb-secure Firmware, Mb-secure Pro and 1 more 2025-05-17 N/A 8.8 HIGH
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability in Honeywell MB-Secure allows Privilege Abuse. This issue affects MB-Secure: from V11.04 before V12.53 and MB-Secure PRO from V01.06 before V03.09.Honeywell also recommends updating to the most recent version of this product.
CVE-2024-46453 1 Honeywell 2 Iq3xcite, Iq3xcite Firmware 2025-03-13 N/A 6.1 MEDIUM
A cross-site scripting (XSS) vulnerability in the component /test/ of iq3xcite v2.31 to v3.05 allows attackers to execute arbitrary web scripts or HTML via a crafted payload.
CVE-2023-51603 1 Honeywell 1 Saia Pg5 Controls Suite 2025-03-12 N/A 8.8 HIGH
Honeywell Saia PG5 Controls Suite CAB File Parsing Directory Traversal Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Honeywell Saia PG5 Controls Suite. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of CAB files. The issue results from the lack of proper validation of a user-supplied path prior to using it in file operations. An attacker can leverage this vulnerability to execute code in the context of the current user. . Was ZDI-CAN-18592.
CVE-2023-51605 1 Honeywell 1 Saia Pg5 Controls Suite 2025-03-12 N/A 6.5 MEDIUM
Honeywell Saia PG5 Controls Suite XML External Entity Processing Information Disclosure Vulnerability. This vulnerability allows remote attackers to disclose sensitive information on affected installations of Honeywell Saia PG5 Controls Suite. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of XML files. Due to the improper restriction of XML External Entity (XXE) references, a crafted document specifying a URI causes the XML parser to access the URI and embed the contents back into the XML document for further processing. An attacker can leverage this vulnerability to disclose information in the context of the current process. . Was ZDI-CAN-18644.
CVE-2023-51604 1 Honeywell 1 Saia Pg5 Controls Suite 2025-03-12 N/A 6.5 MEDIUM
Honeywell Saia PG5 Controls Suite XML External Entity Processing Information Disclosure Vulnerability. This vulnerability allows remote attackers to disclose sensitive information on affected installations of Honeywell Saia PG5 Controls Suite. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of XML files. Due to the improper restriction of XML External Entity (XXE) references, a crafted document specifying a URI causes the XML parser to access the URI and embed the contents back into the XML document for further processing. An attacker can leverage this vulnerability to disclose information in the context of the current process. . Was ZDI-CAN-18593.
CVE-2023-51602 1 Honeywell 1 Saia Pg5 Controls Suite 2025-03-12 N/A 6.5 MEDIUM
Honeywell Saia PG5 Controls Suite XML External Entity Processing Information Disclosure Vulnerability. This vulnerability allows remote attackers to disclose sensitive information on affected installations of Honeywell Saia PG5 Controls Suite. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of XML files. Due to the improper restriction of XML External Entity (XXE) references, a crafted document specifying a URI causes the XML parser to access the URI and embed the contents back into the XML document for further processing. An attacker can leverage this vulnerability to disclose information in the context of the current process. . Was ZDI-CAN-18591.
CVE-2023-51601 1 Honeywell 1 Saia Pg5 Controls Suite 2025-03-12 N/A 6.5 MEDIUM
Honeywell Saia PG5 Controls Suite XML External Entity Processing Information Disclosure Vulnerability. This vulnerability allows remote attackers to disclose sensitive information on affected installations of Honeywell Saia PG5 Controls Suite. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of xml files. Due to the improper restriction of XML External Entity (XXE) references, a crafted document specifying a URI causes the XML parser to access the URI and embed the contents back into the XML document for further processing. An attacker can leverage this vulnerability to disclose information in the context of the current process. . Was ZDI-CAN-18563.
CVE-2023-51600 1 Honeywell 1 Saia Pg5 Controls Suite 2025-03-12 N/A 6.5 MEDIUM
Honeywell Saia PG5 Controls Suite XML External Entity Processing Information Disclosure Vulnerability. This vulnerability allows remote attackers to disclose sensitive information on affected installations of Honeywell Saia PG5 Controls Suite. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of XML files. Due to the improper restriction of XML External Entity (XXE) references, a crafted document specifying a URI causes the XML parser to access the URI and embed the contents back into the XML document for further processing. An attacker can leverage this vulnerability to disclose information in the context of the current process. . Was ZDI-CAN-18456.
CVE-2023-51599 1 Honeywell 1 Saia Pg5 Controls Suite 2025-03-12 N/A 8.8 HIGH
Honeywell Saia PG5 Controls Suite Directory Traversal Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Honeywell Saia PG5 Controls Suite. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of ZIP files. The issue results from the lack of proper validation of a user-supplied path prior to using it in file operations. An attacker can leverage this vulnerability to execute code in the context of the current user. . Was ZDI-CAN-18412.
CVE-2023-1841 1 Honeywell 2 Mpa2, Mpa2 Firmware 2025-03-04 N/A 4.8 MEDIUM
Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in Honeywell MPA2 Access Panel (Web server modules) allows XSS Using Invalid Characters.This issue affects MPA2 Access Panel all version prior to R1.00.08.05.  Honeywell released firmware update package MPA2 firmware R1.00.08.05 which addresses this vulnerability. This version and all later versions correct the reported vulnerability.
CVE-2023-3243 1 Honeywell 2 Alerton Bcm-web, Alerton Bcm-web Firmware 2024-08-02 N/A 9.8 CRITICAL
** UNSUPPORTED WHEN ASSIGNED ** [An attacker can capture an authenticating hash and utilize it to create new sessions. The hash is also a poorly salted MD5 hash, which could result in a successful brute force password attack. Impacted product is BCM-WEB version 3.3.X. Recommended fix: Upgrade to a supported product such as Alerton ACM.] Out of an abundance of caution, this CVE ID is being assigned to better serve our customers and ensure all who are still running this product understand that the product is end of life and should be removed or upgraded. 
CVE-2023-5390 1 Honeywell 4 Controledge Unit Operations Controller, Controledge Unit Operations Controller Firmware, Controledge Virtual Unit Operations Controller and 1 more 2024-07-09 N/A 5.3 MEDIUM
An attacker could potentially exploit this vulnerability, leading to files being read from the Honeywell Experion ControlEdge VirtualUOC and ControlEdge UOC. This exploit could be used to read files from the controller that may expose limited information from the device. Honeywell recommends updating to the most recent version of the product. See Honeywell Security Notification for recommendations on upgrading and versioning.
CVE-2023-24480 1 Honeywell 2 C300, C300 Firmware 2024-04-22 N/A 7.5 HIGH
Controller DoS due to stack overflow when decoding a message from the server.  See Honeywell Security Notification for recommendations on upgrading and versioning.
CVE-2023-25078 1 Honeywell 4 Direct Station, Engineering Station, Experion Server and 1 more 2024-04-22 N/A 7.5 HIGH
Server or Console Station DoS due to heap overflow occurring during the handling of a specially crafted message for a specific configuration operation.  See Honeywell Security Notification for recommendations on upgrading and versioning.
CVE-2023-26597 1 Honeywell 2 C300, C300 Firmware 2024-04-22 N/A 7.5 HIGH
Controller DoS due to buffer overflow in the handling of a specially crafted message received by the controller. See Honeywell Security Notification for recommendations on upgrading and versioning. See Honeywell Security Notification for recommendations on upgrading and versioning.
CVE-2023-25770 1 Honeywell 2 C300, C300 Firmware 2024-04-22 N/A 7.5 HIGH
Controller DoS may occur due to buffer overflow when an error is generated in response to a specially crafted message. See Honeywell Security Notification for recommendations on upgrading and versioning.
CVE-2023-23585 1 Honeywell 4 Direct Station, Engineering Station, Experion Server and 1 more 2024-04-22 N/A 7.5 HIGH
Experion server DoS due to heap overflow occurring during the handling of a specially crafted message for a specific configuration operation.  See Honeywell Security Notification for recommendations on upgrading and versioning.
CVE-2023-25178 1 Honeywell 2 C300, C300 Firmware 2024-04-22 N/A 9.8 CRITICAL
Controller may be loaded with malicious firmware which could enable remote code execution. See Honeywell Security Notification for recommendations on upgrading and versioning.
CVE-2023-25948 1 Honeywell 4 Direct Station, Engineering Station, Experion Server and 1 more 2024-04-22 N/A 7.5 HIGH
Server information leak of configuration data when an error is generated in response to a specially crafted message. See Honeywell Security Notification for recommendations on upgrading and versioning.