CVE-2023-51603

Honeywell Saia PG5 Controls Suite CAB File Parsing Directory Traversal Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Honeywell Saia PG5 Controls Suite. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of CAB files. The issue results from the lack of proper validation of a user-supplied path prior to using it in file operations. An attacker can leverage this vulnerability to execute code in the context of the current user. . Was ZDI-CAN-18592.
Configurations

Configuration 1 (hide)

OR cpe:2.3:a:honeywell:saia_pg5_controls_suite:-:*:*:*:*:*:*:*
cpe:2.3:a:honeywell:saia_pg5_controls_suite:2.3.193:*:*:*:*:*:*:*

History

12 Mar 2025, 13:46

Type Values Removed Values Added
CVSS v2 : unknown
v3 : unknown
v2 : unknown
v3 : 8.8
CPE cpe:2.3:a:honeywell:saia_pg5_controls_suite:2.3.193:*:*:*:*:*:*:*
cpe:2.3:a:honeywell:saia_pg5_controls_suite:-:*:*:*:*:*:*:*
References () https://www.zerodayinitiative.com/advisories/ZDI-23-1852/ - () https://www.zerodayinitiative.com/advisories/ZDI-23-1852/ - Third Party Advisory
First Time Honeywell saia Pg5 Controls Suite
Honeywell

18 Sep 2024, 19:15

Type Values Removed Values Added
Summary Honeywell Saia PG5 Controls Suite CAB File Parsing Directory Traversal Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Honeywell Saia PG5 Controls Suite. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of CAB files. The issue results from the lack of proper validation of a user-supplied path prior to using it in file operations. An attacker can leverage this vulnerability to execute code in the context of the current user. Was ZDI-CAN-18592. Honeywell Saia PG5 Controls Suite CAB File Parsing Directory Traversal Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Honeywell Saia PG5 Controls Suite. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of CAB files. The issue results from the lack of proper validation of a user-supplied path prior to using it in file operations. An attacker can leverage this vulnerability to execute code in the context of the current user. . Was ZDI-CAN-18592.

03 May 2024, 03:16

Type Values Removed Values Added
New CVE

Information

Published : 2024-05-03 03:16

Updated : 2025-03-12 13:46


NVD link : CVE-2023-51603

Mitre link : CVE-2023-51603


JSON object : View

Products Affected

honeywell

  • saia_pg5_controls_suite
CWE

No CWE.