CVE Vendors Products Updated CVSS v2 CVSS v3
CVE-2022-1596 1 Abb 6 Rex640 Pcl1, Rex640 Pcl1 Firmware, Rex640 Pcl2 and 3 more 2022-06-29 4.0 MEDIUM 6.5 MEDIUM
Incorrect Permission Assignment for Critical Resource vulnerability in ABB REX640 PCL1, REX640 PCL2, REX640 PCL3 allows an authenticated attacker to launch an attack against the user database file and try to take control of an affected system node.
CVE-2022-26057 1 Abb 1 Mint Workbench 2022-06-24 7.2 HIGH 7.8 HIGH
Vulnerabilities in the Mint WorkBench allow a low privileged attacker to create and write to a file anywhere on the file system as SYSTEM with arbitrary content as long as the file does not already exist. The Mint WorkBench installer file allows a low-privileged user to run a "repair" operation on the product
CVE-2022-29483 1 Abb 1 E-design 2022-06-11 7.2 HIGH 7.8 HIGH
Incorrect Default Permissions vulnerability in ABB e-Design allows attacker to install malicious software executing with SYSTEM permissions violating confidentiality, integrity, and availability of the target machine.
CVE-2022-0947 1 Abb 48 Arc600a2323na, Arc600a2323na Firmware, Arc600a2324na and 45 more 2022-05-18 6.8 MEDIUM 9.8 CRITICAL
A vulnerability in ABB ARG600 Wireless Gateway series that could allow an attacker to exploit the vulnerability by remotely connecting to the serial port gateway, and/or protocol converter, depending on the configuration.
CVE-2021-22277 1 Abb 4 800xa, Base Software, Compact Product Suite and 1 more 2022-04-11 7.8 HIGH 7.5 HIGH
Improper Input Validation vulnerability in ABB 800xA, Control Software for AC 800M, Control Builder Safe, Compact Product Suite - Control and I/O, ABB Base Software for SoftControl allows an attacker to cause the denial of service.
CVE-2021-22286 1 Abb 4 Pni800, Pni800 Firmware, Spiet800 and 1 more 2022-02-09 5.0 MEDIUM 7.5 HIGH
Improper Input Validation vulnerability in the ABB SPIET800 and PNI800 module allows an attacker to cause the denial of service or make the module unresponsive.
CVE-2021-22288 1 Abb 4 Pni800, Pni800 Firmware, Spiet800 and 1 more 2022-02-09 5.0 MEDIUM 7.5 HIGH
Improper Input Validation vulnerability in the ABB SPIET800 and PNI800 module allows an attacker to cause the denial of service or make the module unresponsive.
CVE-2021-22284 1 Abb 1 Opc Server For Ac 800m 2022-02-09 6.5 MEDIUM 8.8 HIGH
Incorrect Permission Assignment for Critical Resource vulnerability in OPC Server for AC 800M allows an attacker to execute arbitrary code in the node running the AC800M OPC Server.
CVE-2019-10953 5 Abb, Phoenixcontact, Schneider-electric and 2 more 20 Pm554-tp-eth, Pm554-tp-eth Firmware, Ilc 151 Eth and 17 more 2022-01-31 5.0 MEDIUM 7.5 HIGH
ABB, Phoenix Contact, Schneider Electric, Siemens, WAGO - Programmable Logic Controllers, multiple versions. Researchers have found some controllers are susceptible to a denial-of-service attack due to a flood of network packets.
CVE-2019-7229 1 Abb 15 Board Support Package Un31, Cp620, Cp620-web and 12 more 2022-01-01 5.4 MEDIUM 8.3 HIGH
The ABB CP635 HMI uses two different transmission methods to upgrade its firmware and its software components: "Utilization of USB/SD Card to flash the device" and "Remote provisioning process via ABB Panel Builder 600 over FTP." Neither of these transmission methods implements any form of encryption or authenticity checks against the new firmware HMI software binary files.
CVE-2021-22279 1 Abb 2 Omnicore C30, Omnicore C30 Firmware 2021-12-17 9.3 HIGH 9.8 CRITICAL
A Missing Authentication vulnerability in RobotWare for the OmniCore robot controller allows an attacker to read and modify files on the robot controller if the attacker has access to the Connected Services Gateway Ethernet port.
CVE-2019-19107 2 Abb, Busch-jaeger 4 Tg\/s3.2, Tg\/s3.2 Firmware, 6186\/11 and 1 more 2021-11-03 2.1 LOW 5.5 MEDIUM
The Configuration pages in ABB Telephone Gateway TG/S 3.2 and Busch-Jaeger 6186/11 Telefon-Gateway for user profiles and services transfer the password in plaintext (although hidden when displayed).
CVE-2019-19104 2 Abb, Busch-jaeger 4 Tg\/s3.2, Tg\/s3.2 Firmware, 6186\/11 and 1 more 2021-11-03 7.5 HIGH 9.8 CRITICAL
The web server in ABB Telephone Gateway TG/S 3.2 and Busch-Jaeger 6186/11 Telefon-Gateway allows access to different endpoints of the application without authenticating by accessing a specific uniform resource locator (URL) , violating the access-control (ACL) rules. This issue allows obtaining sensitive information that may aid in further attacks and privilege escalation.
CVE-2019-18250 1 Abb 2 Plant Connect, Power Generation Information Manager 2021-10-29 7.5 HIGH 9.8 CRITICAL
In all versions of ABB Power Generation Information Manager (PGIM) and Plant Connect, the affected product is vulnerable to authentication bypass, which may allow an attacker to remotely bypass authentication and extract credentials from the affected device.
CVE-2021-22272 2 Abb, Busch-jaeger 2 Mybuildings, Mybusch-jaeger 2021-10-08 9.0 HIGH 9.4 CRITICAL
The vulnerability origins in the commissioning process where an attacker of the ControlTouch can enter a serial number in a specific way to transfer the device virtually into her/his my.busch-jaeger.de or mybuildings.abb.com profile. A successful attacker can observe and control a ControlTouch remotely under very specific circumstances. The issue is fixed in the cloud side of the system. No firmware update is needed for customer products. If a user wants to understand if (s)he is affected, please read the advisory. This issue affects: ABB and Busch-Jaeger, ControlTouch
CVE-2020-24683 1 Abb 2 Symphony \+ Historian, Symphony \+ Operations 2021-10-07 7.5 HIGH 9.8 CRITICAL
The affected versions of S+ Operations (version 2.1 SP1 and earlier) used an approach for user authentication which relies on validation at the client node (client-side authentication). This is not as secure as having the server validate a client application before allowing a connection. Therefore, if the network communication or endpoints for these applications are not protected, unauthorized actors can bypass authentication and make unauthorized connections to the server application.
CVE-2020-24679 1 Abb 2 Symphony \+ Historian, Symphony \+ Operations 2021-10-07 10.0 HIGH 9.8 CRITICAL
A S+ Operations and S+ Historian service is subject to a DoS by special crafted messages. An attacker might use this flaw to make it crash or even execute arbitrary code on the machine where the service is hosted.
CVE-2020-24680 1 Abb 2 Symphony \+ Historian, Symphony \+ Operations 2021-10-07 4.6 MEDIUM 7.0 HIGH
In S+ Operations and S+ Historian, the passwords of internal users (not Windows Users) are encrypted but improperly stored in a database.
CVE-2020-24675 1 Abb 2 Symphony \+ Historian, Symphony \+ Operations 2021-10-07 7.5 HIGH 9.8 CRITICAL
In S+ Operations and S+ History, it is possible that an unauthenticated user could inject values to the Operations History server (or standalone S+ History server) and ultimately write values to the controlled process.
CVE-2020-24678 1 Abb 2 Symphony \+ Historian, Symphony \+ Operations 2021-10-07 6.5 MEDIUM 8.8 HIGH
An authenticated user might execute malicious code under the user context and take control of the system. S+ Operations or S+ Historian database is affected by multiple vulnerabilities such as the possibility to allow remote authenticated users to gain high privileges.