Filtered by vendor Schneider-electric
Subscribe
Total
757 CVE
| CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
|---|---|---|---|---|---|
| CVE-2020-7554 | 1 Schneider-electric | 1 Interactive Graphical Scada System | 2021-02-01 | 6.8 MEDIUM | 7.8 HIGH |
| A CWE-119 Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists in IGSS Definition (Def.exe) version 14.0.0.20247 that could cause Remote Code Execution when malicious CGF (Configuration Group File) file is imported to IGSS Definition. | |||||
| CVE-2020-7556 | 1 Schneider-electric | 1 Interactive Graphical Scada System | 2021-02-01 | 6.8 MEDIUM | 7.8 HIGH |
| A CWE-787 Out-of-bounds Write vulnerability exists in IGSS Definition (Def.exe) version 14.0.0.20247 that could cause Remote Code Execution when malicious CGF (Configuration Group File) file is imported to IGSS Definition. | |||||
| CVE-2020-7557 | 1 Schneider-electric | 1 Interactive Graphical Scada System | 2021-02-01 | 6.8 MEDIUM | 7.8 HIGH |
| A CWE-125 Out-of-bounds Read vulnerability exists in IGSS Definition (Def.exe) version 14.0.0.20247 that could cause Remote Code Execution when malicious CGF (Configuration Group File) file is imported to IGSS Definition. | |||||
| CVE-2020-7558 | 1 Schneider-electric | 1 Interactive Graphical Scada System | 2021-02-01 | 6.8 MEDIUM | 7.8 HIGH |
| A CWE-787 Out-of-bounds Write vulnerability exists in IGSS Definition (Def.exe) version 14.0.0.20247 that could cause Remote Code Execution when malicious CGF (Configuration Group File) file is imported to IGSS Definition. | |||||
| CVE-2020-7555 | 1 Schneider-electric | 1 Interactive Graphical Scada System | 2021-01-30 | 6.8 MEDIUM | 7.8 HIGH |
| A CWE-787 Out-of-bounds Write vulnerability exists in IGSS Definition (Def.exe) version 14.0.0.20247 that could cause Remote Code Execution when malicious CGF (Configuration Group File) file is imported to IGSS Definition. | |||||
| CVE-2020-28219 | 1 Schneider-electric | 2 Ecostruxure Geo Scada Expert 2019, Ecostruxure Geo Scada Expert 2020 | 2020-12-16 | 2.1 LOW | 7.8 HIGH |
| A CWE-522: Insufficiently Protected Credentials vulnerability exists in EcoStruxure Geo SCADA Expert 2019 (Original release and Monthly Updates to September 2020, from 81.7268.1 to 81.7578.1) and EcoStruxure Geo SCADA Expert 2020 (Original release and Monthly Updates to September 2020, from 83.7551.1 to 83.7578.1), that could cause exposure of credentials to server-side users when web users are logged in to Virtual ViewX. | |||||
| CVE-2020-28218 | 1 Schneider-electric | 2 Easergy T300, Easergy T300 Firmware | 2020-12-14 | 4.3 MEDIUM | 6.5 MEDIUM |
| A CWE-1021: Improper Restriction of Rendered UI Layers or Frames vulnerability exists in Easergy T300 (firmware 2.7 and older), that would allow an attacker to trick a user into initiating an unintended action. | |||||
| CVE-2020-28217 | 1 Schneider-electric | 2 Easergy T300, Easergy T300 Firmware | 2020-12-14 | 5.0 MEDIUM | 7.5 HIGH |
| A CWE-311: Missing Encryption of Sensitive Data vulnerability exists in Easergy T300 (firmware 2.7 and older), that would allow an attacker to read network traffic over HTTP protocol. | |||||
| CVE-2020-28215 | 1 Schneider-electric | 2 Easergy T300, Easergy T300 Firmware | 2020-12-14 | 7.5 HIGH | 9.8 CRITICAL |
| A CWE-862: Missing Authorization vulnerability exists in Easergy T300 (firmware 2.7 and older), that could cause a wide range of problems, including information exposures, denial of service, and arbitrary code execution when access control checks are not applied consistently. | |||||
| CVE-2020-28216 | 1 Schneider-electric | 2 Easergy T300, Easergy T300 Firmware | 2020-12-14 | 5.0 MEDIUM | 7.5 HIGH |
| A CWE-311: Missing Encryption of Sensitive Data vulnerability exists in Easergy T300 (firmware 2.7 and older), that would allow an attacker to read network traffic over HTTP protocol. | |||||
| CVE-2020-7548 | 1 Schneider-electric | 14 Acti9 Powertag Link, Acti9 Powertag Link Firmware, Acti9 Powertag Link Hd and 11 more | 2020-12-08 | 7.5 HIGH | 9.8 CRITICAL |
| A CWE-330 - Use of Insufficiently Random Values vulnerability exists in Smartlink, PowerTag, and Wiser Series Gateways (see security notification for version information) that could allow unauthorized users to login. | |||||
| CVE-2020-7546 | 1 Schneider-electric | 5 Ecostruxure Energy Expert, Ecostruxure Power Monitoring Expert, Power Manager and 2 more | 2020-12-04 | 3.5 LOW | 5.4 MEDIUM |
| A CWE-79: Improper Neutralization of Input During Web Page Generation vulnerability exists in EcoStruxureª and SmartStruxureª Power Monitoring and SCADA Software (see security notification for version information) that could allow an attacker to perform actions on behalf of the authorized user when accessing an affected webpage. | |||||
| CVE-2020-7562 | 1 Schneider-electric | 40 Modicon M340 Bmx Noc 0401, Modicon M340 Bmx Noc 0401 Firmware, Modicon M340 Bmx Noe 0100 and 37 more | 2020-12-02 | 5.8 MEDIUM | 8.1 HIGH |
| A CWE-125: Out-of-Bounds Read vulnerability exists in the Web Server on Modicon M340, Modicon Quantum and Modicon Premium Legacy offers and their Communication Modules (see notification for details) which could cause a segmentation fault or a buffer overflow when uploading a specially crafted file on the controller over FTP. | |||||
| CVE-2020-7563 | 1 Schneider-electric | 40 Modicon M340 Bmx Noc 0401, Modicon M340 Bmx Noc 0401 Firmware, Modicon M340 Bmx Noe 0100 and 37 more | 2020-12-02 | 6.5 MEDIUM | 8.8 HIGH |
| A CWE-787: Out-of-bounds Write vulnerability exists in the Web Server on Modicon M340, Modicon Quantum and Modicon Premium Legacy offers and their Communication Modules (see notification for details) which could cause corruption of data, a crash, or code execution when uploading a specially crafted file on the controller over FTP. | |||||
| CVE-2020-7564 | 1 Schneider-electric | 40 Modicon M340 Bmx Noc 0401, Modicon M340 Bmx Noc 0401 Firmware, Modicon M340 Bmx Noe 0100 and 37 more | 2020-12-02 | 6.5 MEDIUM | 8.8 HIGH |
| A CWE-120: Buffer Copy without Checking Size of Input ('Classic Buffer Overflow') vulnerability exists in the Web Server on Modicon M340, Modicon Quantum and Modicon Premium Legacy offers and their Communication Modules (see notification for details) which could cause write access and the execution of commands when uploading a specially crafted file on the controller over FTP. | |||||
| CVE-2019-10981 | 1 Schneider-electric | 2 Citectscada, Scada Expert Vijeo Citect | 2020-10-02 | 2.1 LOW | 7.8 HIGH |
| In Vijeo Citect 7.30 and 7.40, and CitectSCADA 7.30 and 7.40, a vulnerability has been identified that may allow an authenticated local user access to Citect user credentials. | |||||
| CVE-2018-7824 | 2 Microsoft, Schneider-electric | 3 Windows, Driver Suite, Modbus Serial Driver | 2020-09-29 | 6.8 MEDIUM | 4.9 MEDIUM |
| An Externally Controlled Reference to a Resource (CWE-610) vulnerability exists in Schneider Electric Modbus Serial Driver (For 64-bit Windows OS:V3.17 IE 37 and prior , For 32-bit Windows OS:V2.17 IE 27 and prior, and as part of the Driver Suite version:V14.12 and prior) which could allow write access to system files available only to users with SYSTEM privilege or other important user files. | |||||
| CVE-2018-7788 | 1 Schneider-electric | 2 Modicon Quantum, Modicon Quantum Firmware | 2020-09-29 | 4.0 MEDIUM | 6.5 MEDIUM |
| A CWE-255 Credentials Management vulnerability exists in Modicon Quantum with firmware versions prior to V2.40. which could cause a Denial Of Service when using a Telnet connection. | |||||
| CVE-2020-7528 | 1 Schneider-electric | 1 Scadapack 7x Remote Connect | 2020-09-21 | 6.8 MEDIUM | 7.8 HIGH |
| A CWE-502 Deserialization of Untrusted Data vulnerability exists in SCADAPack 7x Remote Connect (V3.6.3.574 and prior) which could allow arbitrary code execution when an attacker builds a custom .PRJ file containing a malicious serialized buffer. | |||||
| CVE-2020-7529 | 1 Schneider-electric | 1 Scadapack 7x Remote Connect | 2020-09-21 | 4.3 MEDIUM | 5.5 MEDIUM |
| A CWE-22 Improper Limitation of a Pathname to a Restricted Directory ('Path Transversal') vulnerability exists in SCADAPack 7x Remote Connect (V3.6.3.574 and prior) which allows an attacker to place content in any unprotected folder on the target system using a crafted .RCZ file. | |||||