CVE-2022-34757 1 Schneider-electric 2 Easergy P5, Easergy P5 Firmware 2022-07-27 N/A 5.3 MEDIUM
A CWE-327: Use of a Broken or Risky Cryptographic Algorithm vulnerability exists where weak cipher suites can be used for the SSH connection between Easergy Pro software and the device, which may allow an attacker to observe protected communication details. Affected Products: Easergy P5 (V01.401.102 and prior)
CVE-2022-34756 1 Schneider-electric 2 Easergy P5, Easergy P5 Firmware 2022-07-27 N/A 9.8 CRITICAL
A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could result in remote code execution or the crash of HTTPs stack which is used for the device Web HMI. Affected Products: Easergy P5 (V01.401.102 and prior)
CVE-2022-34753 1 Schneider-electric 2 Spacelogic C-bus Home Controller, Spacelogic C-bus Home Controller Firmware 2022-07-27 N/A 8.8 HIGH
A CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability exists that could cause remote root exploit when the command is compromised. Affected Products: SpaceLogic C-Bus Home Controller (5200WHC2), formerly known as C-Bus Wiser Homer Controller MK2 (V1.31.460 and prior)
CVE-2022-34754 1 Schneider-electric 4 Acti9 Powertag Link C \(a9xelc10-a\), Acti9 Powertag Link C \(a9xelc10-a\) Firmware, Acti9 Powertag Link C \(a9xelc10-b\) and 1 more 2022-07-22 N/A 6.8 MEDIUM
A CWE-269: Improper Privilege Management vulnerability exists that could allow elevated functionality when guessing credentials. Affected Products: Acti9 PowerTag Link C (A9XELC10-A) (V1.7.5 and prior), Acti9 PowerTag Link C (A9XELC10-B) (V2.12.0 and prior)
CVE-2022-34765 1 Schneider-electric 4 Opc Ua Module For M580, Opc Ua Module For M580 Firmware, X80 Advanced Rtu Module and 1 more 2022-07-21 N/A 5.3 MEDIUM
A CWE-73: External Control of File Name or Path vulnerability exists that could cause loading of unauthorized firmware images when user-controlled data is written to the file path. Affected Products: X80 advanced RTU Communication Module (BMENOR2200H) (V2.01 and later), OPC UA Modicon Communication Module (BMENUA0100) (V1.10 and prior)
CVE-2022-34764 1 Schneider-electric 4 Opc Ua Module For M580, Opc Ua Module For M580 Firmware, X80 Advanced Rtu Module and 1 more 2022-07-21 N/A 7.5 HIGH
A CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists that could cause denial of service when parsing the URL. Affected Products: X80 advanced RTU Communication Module (BMENOR2200H) (V1.0), OPC UA Modicon Communication Module (BMENUA0100) (V1.10 and prior)
CVE-2022-32530 1 Schneider-electric 1 Geo Scada Mobile 2022-07-06 6.8 MEDIUM 7.8 HIGH
A CWE-668 Exposure of Resource to Wrong Sphere vulnerability exists that could cause users to be misled, hiding alarms, showing the wrong server connection option or the wrong control request when a mobile device has been compromised by a malicious application. Affected Product: Geo SCADA Mobile (Build 222 and prior)
CVE-2022-30238 1 Schneider-electric 4 Wiser Smart Eer21000, Wiser Smart Eer21000 Firmware, Wiser Smart Eer21001 and 1 more 2022-06-13 7.5 HIGH 8.8 HIGH
A CWE-287: Improper Authentication vulnerability exists that could allow an attacker to take over the admin account when an attacker hijacks a session. Affected Products: Wiser Smart, EER21000 & EER21001 (V4.5 and prior)
CVE-2022-30237 1 Schneider-electric 4 Wiser Smart Eer21000, Wiser Smart Eer21000 Firmware, Wiser Smart Eer21001 and 1 more 2022-06-13 5.0 MEDIUM 7.5 HIGH
A CWE-311: Missing Encryption of Sensitive Data vulnerability exists that could allow authentication credentials to be recovered when an attacker breaks the encoding. Affected Products: Wiser Smart, EER21000 & EER21001 (V4.5 and prior)
CVE-2022-30236 1 Schneider-electric 4 Wiser Smart Eer21000, Wiser Smart Eer21000 Firmware, Wiser Smart Eer21001 and 1 more 2022-06-13 6.4 MEDIUM 8.2 HIGH
A CWE-669: Incorrect Resource Transfer Between Spheres vulnerability exists that could allow unauthorized access when an attacker uses cross-domain attacks. Affected Products: Wiser Smart, EER21000 & EER21001 (V4.5 and prior)
CVE-2022-30235 1 Schneider-electric 4 Wiser Smart Eer21000, Wiser Smart Eer21000 Firmware, Wiser Smart Eer21001 and 1 more 2022-06-13 5.0 MEDIUM 9.8 CRITICAL
A CWE-307: Improper Restriction of Excessive Authentication Attempts vulnerability exists that could allow unauthorized access when an attacker uses brute force. Affected Products: Wiser Smart, EER21000 & EER21001 (V4.5 and prior)
CVE-2022-30234 1 Schneider-electric 4 Wiser Smart Eer21000, Wiser Smart Eer21000 Firmware, Wiser Smart Eer21001 and 1 more 2022-06-13 10.0 HIGH 9.8 CRITICAL
A CWE-798: Use of Hard-coded Credentials vulnerability exists that could allow arbitrary code to be executed when root level access is obtained. Affected Products: Wiser Smart, EER21000 & EER21001 (V4.5 and prior)
CVE-2022-30233 1 Schneider-electric 4 Wiser Smart Eer21000, Wiser Smart Eer21000 Firmware, Wiser Smart Eer21001 and 1 more 2022-06-13 4.3 MEDIUM 6.5 MEDIUM
A CWE-20: Improper Input Validation vulnerability exists that could allow the product to be maliciously manipulated when the user is tricked into performing certain actions on a webpage. Affected Products: Wiser Smart, EER21000 & EER21001 (V4.5 and prior)
CVE-2022-30232 1 Schneider-electric 2 Powerlogic Ion Setup, Powerlogic Ion Setup Firmware 2022-06-13 6.5 MEDIUM 8.8 HIGH
A CWE-20: Improper Input Validation vulnerability exists that could cause potential remote code execution when an attacker is able to intercept and modify a request on the same network or has configuration access to an ION device on the network. Affected Products: Wiser Smart, EER21000 & EER21001 (V4.5 and prior)
CVE-2018-2800 6 Canonical, Debian, Hp and 3 more 14 Ubuntu Linux, Debian Linux, Xp7 Command View and 11 more 2022-05-13 4.0 MEDIUM 4.2 MEDIUM
Vulnerability in the Java SE, JRockit component of Oracle Java SE (subcomponent: RMI). Supported versions that are affected are Java SE: 6u181, 7u171 and 8u162; JRockit: R28.3.17. Difficult to exploit vulnerability allows unauthenticated attacker with network access via multiple protocols to compromise Java SE, JRockit. Successful attacks require human interaction from a person other than the attacker. Successful attacks of this vulnerability can result in unauthorized update, insert or delete access to some of Java SE, JRockit accessible data as well as unauthorized read access to a subset of Java SE, JRockit accessible data. Note: This vulnerability can only be exploited by supplying data to APIs in the specified Component without using Untrusted Java Web Start applications or Untrusted Java applets, such as through a web service. CVSS 3.0 Base Score 4.2 (Confidentiality and Integrity impacts). CVSS Vector: (CVSS:3.0/AV:N/AC:H/PR:N/UI:R/S:U/C:L/I:L/A:N).
CVE-2018-2657 4 Hp, Oracle, Redhat and 1 more 12 Xp7 Command View, Xp Command View, Xp P9000 Command View and 9 more 2022-05-13 5.0 MEDIUM 5.3 MEDIUM
Vulnerability in the Java SE, JRockit component of Oracle Java SE (subcomponent: Serialization). Supported versions that are affected are Java SE: 6u171 and 7u161; JRockit: R28.3.16. Easily exploitable vulnerability allows unauthenticated attacker with network access via multiple protocols to compromise Java SE, JRockit. Successful attacks of this vulnerability can result in unauthorized ability to cause a partial denial of service (partial DOS) of Java SE, JRockit. Note: This vulnerability can only be exploited by supplying data to APIs in the specified Component without using Untrusted Java Web Start applications or Untrusted Java applets, such as through a web service. CVSS 3.0 Base Score 5.3 (Availability impacts). CVSS Vector: (CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L).
CVE-2022-22805 1 Schneider-electric 16 Scl Series 1029 Ups, Scl Series 1029 Ups Firmware, Scl Series 1030 Ups and 13 more 2022-05-12 7.5 HIGH 9.8 CRITICAL
A CWE-120: Buffer Copy without Checking Size of Input ('Classic Buffer Overflow') vulnerability exists that could cause remote code execution when an improperly handled TLS packet is reassembled. Affected Product: SmartConnect Family: SMT Series (SMT Series ID=1015: UPS 04.5 and prior), SMC Series (SMC Series ID=1018: UPS 04.2 and prior), SMTL Series (SMTL Series ID=1026: UPS 02.9 and prior), SCL Series (SCL Series ID=1029: UPS 02.5 and prior / SCL Series ID=1030: UPS 02.5 and prior / SCL Series ID=1036: UPS 02.5 and prior / SCL Series ID=1037: UPS 03.1 and prior), SMX Series (SMX Series ID=1031: UPS 03.1 and prior)
CVE-2022-22806 1 Schneider-electric 16 Scl Series 1029 Ups, Scl Series 1029 Ups Firmware, Scl Series 1030 Ups and 13 more 2022-05-12 7.5 HIGH 9.8 CRITICAL
A CWE-294: Authentication Bypass by Capture-replay vulnerability exists that could cause an unauthenticated connection to the UPS when a malformed connection is sent. Affected Product: SmartConnect Family: SMT Series (SMT Series ID=1015: UPS 04.5 and prior), SMC Series (SMC Series ID=1018: UPS 04.2 and prior), SMTL Series (SMTL Series ID=1026: UPS 02.9 and prior), SCL Series (SCL Series ID=1029: UPS 02.5 and prior / SCL Series ID=1030: UPS 02.5 and prior / SCL Series ID=1036: UPS 02.5 and prior / SCL Series ID=1037: UPS 03.1 and prior), SMX Series (SMX Series ID=1031: UPS 03.1 and prior)
CVE-2020-7491 1 Schneider-electric 14 Tricon Tcm 4351, Tricon Tcm 4351 Firmware, Tricon Tcm 4351a and 11 more 2022-04-27 5.0 MEDIUM 7.5 HIGH
**VERSION NOT SUPPORTED WHEN ASSIGNED** A legacy debug port account in TCMs installed in Tricon system versions 10.2.0 through 10.5.3 is visible on the network and could allow inappropriate access. This vulnerability was remediated in TCM version 10.5.4.
CVE-2021-22797 1 Schneider-electric 8 Ecostruxure Control Expert, Ecostruxure Process Expert, Remoteconnect and 5 more 2022-04-23 9.3 HIGH 7.8 HIGH
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal) vulnerability exists that could cause malicious script to be deployed in an unauthorized location and may result in code execution on the engineering workstation when a malicious project file is loaded in the engineering software. Affected Product: EcoStruxure Control Expert (V15.0 SP1 and prior, including former Unity Pro), EcoStruxure Process Expert (2020 and prior, including former HDCS), SCADAPack RemoteConnect for x70 (All versions)