Total
1255 CVE
CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
---|---|---|---|---|---|
CVE-2018-1113 | 2 Fedoraproject, Redhat | 6 Fedora, Enterprise Linux, Enterprise Linux Desktop and 3 more | 2019-10-09 | 4.6 MEDIUM | 5.3 MEDIUM |
setup before version 2.11.4-1.fc28 in Fedora and Red Hat Enterprise Linux added /sbin/nologin and /usr/sbin/nologin to /etc/shells. This violates security assumptions made by pam_shells and some daemons which allow access based on a user's shell being listed in /etc/shells. Under some circumstances, users which had their shell changed to /sbin/nologin could still access the system. | |||||
CVE-2018-15379 | 1 Cisco | 1 Prime Infrastructure | 2019-10-09 | 7.5 HIGH | 9.8 CRITICAL |
A vulnerability in which the HTTP web server for Cisco Prime Infrastructure (PI) has unrestricted directory permissions could allow an unauthenticated, remote attacker to upload an arbitrary file. This file could allow the attacker to execute commands at the privilege level of the user prime. This user does not have administrative or root privileges. The vulnerability is due to an incorrect permission setting for important system directories. An attacker could exploit this vulnerability by uploading a malicious file by using TFTP, which can be accessed via the web-interface GUI. A successful exploit could allow the attacker to run commands on the targeted application without authentication. | |||||
CVE-2018-14825 | 2 Google, Honeywell | 15 Android, Ck75, Cn51 and 12 more | 2019-10-09 | 6.8 MEDIUM | 5.8 MEDIUM |
On Honeywell Mobile Computers (CT60 running Android OS 7.1, CN80 running Android OS 7.1, CT40 running Android OS 7.1, CK75 running Android OS 6.0, CN75 running Android OS 6.0, CN75e running Android OS 6.0, CT50 running Android OS 6.0, D75e running Android OS 6.0, CT50 running Android OS 4.4, D75e running Android OS 4.4, CN51 running Android OS 6.0, EDA50k running Android 4.4, EDA50 running Android OS 7.1, EDA50k running Android OS 7.1, EDA70 running Android OS 7.1, EDA60k running Android OS 7.1, and EDA51 running Android OS 8.1), a skilled attacker with advanced knowledge of the target system could exploit this vulnerability by creating an application that would successfully bind to the service and gain elevated system privileges. This could enable the attacker to obtain access to keystrokes, passwords, personal identifiable information, photos, emails, or business-critical documents. | |||||
CVE-2018-11454 | 1 Siemens | 2 Simatic Step 7 \(tia Portal\), Simatic Wincc \(tia Portal\) | 2019-10-09 | 4.4 MEDIUM | 8.6 HIGH |
A vulnerability has been identified in SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V10, V11, V12 (All versions), SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V13 (All versions < V13 SP2 Update 2), SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V14 (All versions < V14 SP1 Update 6), SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V15 (All versions < V15 Update 2). Improper file permissions in the default installation of TIA Portal may allow an attacker with local file system access to manipulate resources which may be transferred to devices and executed there by a different user. No special privileges are required, but the victim needs to transfer the manipulated files to a device. Execution is caused on the target device rather than on the PG device. | |||||
CVE-2018-10856 | 1 Libpod Project | 1 Libpod | 2019-10-09 | 6.5 MEDIUM | 8.8 HIGH |
It has been discovered that podman before version 0.6.1 does not drop capabilities when executing a container as a non-root user. This results in unnecessary privileges being granted to the container. | |||||
CVE-2018-11078 | 1 Dell | 1 Emc Vplex Geosynchrony | 2019-10-09 | 6.0 MEDIUM | 7.5 HIGH |
Dell EMC VPlex GeoSynchrony, versions prior to 6.1, contains an Insecure File Permissions vulnerability. A remote authenticated malicious user could read from VPN configuration files on and potentially author a MITM attack on the VPN traffic. | |||||
CVE-2018-11080 | 1 Emc | 1 Secure Remote Services | 2019-10-09 | 4.6 MEDIUM | 7.8 HIGH |
Dell EMC Secure Remote Services, versions prior to 3.32.00.08, contains Improper File Permission Vulnerabilities. The application contains multiple configuration files with world-readable permissions that could allow an authenticated malicious user to utilize the file contents to potentially elevate their privileges. | |||||
CVE-2018-11453 | 1 Siemens | 2 Simatic Step 7 \(tia Portal\), Simatic Wincc \(tia Portal\) | 2019-10-09 | 4.6 MEDIUM | 7.8 HIGH |
A vulnerability has been identified in SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V10, V11, V12 (All versions), SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V13 (All versions < V13 SP2 Update 2), SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V14 (All versions < V14 SP1 Update 6), SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V15 (All versions < V15 Update 2). Improper file permissions in the default installation of TIA Portal may allow an attacker with local file system access to insert specially crafted files which may prevent TIA Portal startup (Denial-of-Service) or lead to local code execution. No special privileges are required, but the victim needs to attempt to start TIA Portal after the manipulation. | |||||
CVE-2018-10843 | 1 Redhat | 1 Openshift Container Platform | 2019-10-09 | 9.0 HIGH | 8.8 HIGH |
source-to-image component of Openshift Container Platform before versions atomic-openshift 3.7.53, atomic-openshift 3.9.31 is vulnerable to a privilege escalation which allows the assemble script to run as the root user in a non-privileged container. An attacker can use this flaw to open network connections, and possibly other actions, on the host which are normally only available to a root user. | |||||
CVE-2018-11064 | 1 Dell | 2 Emc Unity Operating Environment, Emc Unityvsa Operating Environment | 2019-10-09 | 4.6 MEDIUM | 7.8 HIGH |
Dell EMC Unity OE versions 4.3.0.x and 4.3.1.x and UnityVSA OE versions 4.3.0.x and 4.3.1.x contains an Incorrect File Permissions vulnerability. A locally authenticated malicious user could potentially exploit this vulnerability to alter multiple library files in service tools that might result in arbitrary code execution with elevated privileges. No user file systems are directly affected by this vulnerability. | |||||
CVE-2018-10612 | 1 Codesys | 12 Control For Beaglebone Sl, Control For Empc-a\/imx6 Sl, Control For Iot2000 Sl and 9 more | 2019-10-09 | 10.0 HIGH | 9.8 CRITICAL |
In 3S-Smart Software Solutions GmbH CODESYS Control V3 products prior to version 3.5.14.0, user access management and communication encryption is not enabled by default, which could allow an attacker access to the device and sensitive information, including user credentials. | |||||
CVE-2018-0088 | 1 Cisco | 3 Ie-4010-16s12p, Ie-4010-4s24p, Industrial Ethernet 4010 Series Firmware | 2019-10-09 | 7.2 HIGH | 6.7 MEDIUM |
A vulnerability in one of the diagnostic test CLI commands on Cisco Industrial Ethernet 4010 Series Switches running Cisco IOS Software could allow an authenticated, local attacker to impact the stability of the device. This could result in arbitrary code execution or a denial of service (DoS) condition. The attacker has to have valid user credentials at privilege level 15. The vulnerability is due to a diagnostic test CLI command that allows the attacker to write to the device memory. An attacker could exploit this vulnerability by authenticating to the targeted device and issuing a specific diagnostic test command at the CLI. An exploit could allow the attacker to overwrite system memory locations, which could have a negative impact on the stability of the device. Cisco Bug IDs: CSCvf71150. | |||||
CVE-2018-0089 | 1 Cisco | 1 Policy Suite | 2019-10-09 | 5.0 MEDIUM | 7.5 HIGH |
A vulnerability in the Policy and Charging Rules Function (PCRF) of the Cisco Policy Suite (CPS) could allow an unauthenticated, remote attacker to access sensitive data. The attacker could use this information to conduct additional reconnaissance attacks. The attacker would also have to have access to the internal VLAN where CPS is deployed. The vulnerability is due to incorrect permissions of certain system files and not sufficiently protecting sensitive data that is at rest. An attacker could exploit the vulnerability by using certain tools available on the internal network interface to request and view system files. An exploit could allow the attacker to find out sensitive information about the application. Cisco Bug IDs: CSCvf77666. | |||||
CVE-2018-0392 | 1 Cisco | 6 Mobility Services Engine 3310, Mobility Services Engine 3310 Firmware, Mobility Services Engine 3355 and 3 more | 2019-10-09 | 2.1 LOW | 5.5 MEDIUM |
A vulnerability in the CLI of Cisco Policy Suite could allow an authenticated, local attacker to access files owned by another user. The vulnerability is due to insufficient access control permissions (i.e., World-Readable). An attacker could exploit this vulnerability by logging in to the CLI. An exploit could allow the attacker to access potentially sensitive files that are owned by a different user. Cisco Bug IDs: CSCvh18087. | |||||
CVE-2018-0352 | 1 Cisco | 1 Wide Area Application Services | 2019-10-09 | 7.2 HIGH | 6.7 MEDIUM |
A vulnerability in the Disk Check Tool (disk-check.sh) for Cisco Wide Area Application Services (WAAS) Software could allow an authenticated, local attacker to elevate their privilege level to root. The attacker must have valid user credentials with super user privileges (level 15) to log in to the device. The vulnerability is due to insufficient validation of script files executed in the context of the Disk Check Tool. An attacker could exploit this vulnerability by replacing one script file with a malicious script file while the affected tool is running. A successful exploit could allow the attacker to gain root-level privileges and take full control of the device. Cisco Bug IDs: CSCvi72673. | |||||
CVE-2017-9626 | 1 Marel | 2 Pluto1203, Pluto2 | 2019-10-09 | 7.5 HIGH | 9.8 CRITICAL |
Systems using the Marel Food Processing Systems Pluto platform do not restrict remote access. Marel has created an update for Pluto-based applications. This update will restrict remote access by implementing SSH authentication. | |||||
CVE-2017-7560 | 1 Redhat | 1 Rhnsd | 2019-10-09 | 4.9 MEDIUM | 5.5 MEDIUM |
It was found that rhnsd PID files are created as world-writable that allows local attackers to fill the disks or to kill selected processes. | |||||
CVE-2017-5260 | 1 Cambiumnetworks | 10 Cnpilot E400, Cnpilot E400 Firmware, Cnpilot E410 and 7 more | 2019-10-09 | 9.0 HIGH | 8.8 HIGH |
In versions 4.3.2-R4 and prior of Cambium Networks cnPilot firmware, although the option to access the configuration file is not available in the normal web administrative console for the 'user' account, the configuration file is accessible via direct object reference (DRO) at http://<device-ip-or-hostname>/goform/down_cfg_file by this otherwise low privilege 'user' account. | |||||
CVE-2017-2612 | 1 Jenkins | 1 Jenkins | 2019-10-09 | 5.5 MEDIUM | 5.4 MEDIUM |
In Jenkins before versions 2.44, 2.32.2 low privilege users were able to override JDK download credentials (SECURITY-392), resulting in future builds possibly failing to download a JDK. | |||||
CVE-2017-1624 | 1 Ibm | 1 Qradar Security Information And Event Manager | 2019-10-09 | 5.5 MEDIUM | 5.4 MEDIUM |
IBM QRadar 7.3 and 7.3.1 specifies permissions for a security-critical resource in a way that allows that resource to be read or modified by unintended actors. IBM X-Force ID: 133122. |