CVE-2018-11454 1 Siemens 2 Simatic Step 7 \(tia Portal\), Simatic Wincc \(tia Portal\) 2019-10-09 4.4 MEDIUM 8.6 HIGH
A vulnerability has been identified in SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V10, V11, V12 (All versions), SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V13 (All versions < V13 SP2 Update 2), SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V14 (All versions < V14 SP1 Update 6), SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V15 (All versions < V15 Update 2). Improper file permissions in the default installation of TIA Portal may allow an attacker with local file system access to manipulate resources which may be transferred to devices and executed there by a different user. No special privileges are required, but the victim needs to transfer the manipulated files to a device. Execution is caused on the target device rather than on the PG device.
CVE-2018-11449 1 Siemens 2 Scalance M875, Scalance M875 Firmware 2019-10-09 2.1 LOW 7.8 HIGH
A vulnerability has been identified in SCALANCE M875 (All versions). An attacker with access to the local file system might obtain passwords for administrative users. Successful exploitation requires read access to files on the local file system. A successful attack could allow an attacker to obtain administrative passwords. At the time of advisory publication no public exploitation of this security vulnerability was known.
CVE-2018-11462 1 Siemens 10 Sinumerik 808d V4.7, Sinumerik 808d V4.7 Firmware, Sinumerik 808d V4.8 and 7 more 2019-10-09 7.5 HIGH 9.8 CRITICAL
A vulnerability has been identified in SINUMERIK 808D V4.7 (All versions), SINUMERIK 808D V4.8 (All versions), SINUMERIK 828D V4.7 (All versions < V4.7 SP6 HF1), SINUMERIK 840D sl V4.7 (All versions < V4.7 SP6 HF5), SINUMERIK 840D sl V4.8 (All versions < V4.8 SP3). By sending a specially crafted authentication request to the affected systems a remote attacker could escalate his privileges to an elevated user account but not to root. The security vulnerability could be exploited by an attacker with network access to the affected systems. Successful exploitation requires no privileges and no user interaction. The vulnerability could allow an attacker to compromise confidentiality, integrity and availability of the system. At the time of advisory publication no public exploitation of this security vulnerability was known.
CVE-2018-11448 1 Siemens 2 Scalance M875, Scalance M875 Firmware 2019-10-09 3.5 LOW 4.8 MEDIUM
A vulnerability has been identified in SCALANCE M875 (All versions). The web interface on port 443/tcp could allow a stored Cross-Site Scripting (XSS) attack if an unsuspecting user is tricked into accessing a malicious link. Successful exploitation requires that the attacker has access to the web interface of an affected device. The attacker must be authenticated as administrative user on the web interface. Afterwards, a legitimate user must access the web interface. A successful attack could allow an attacker to execute malicious code in the browser of a legitimate user. At the time of advisory publication no public exploitation of this security vulnerability was known.
CVE-2018-11455 1 Siemens 1 Automation License Manager 2019-10-09 6.8 MEDIUM 8.8 HIGH
A vulnerability has been identified in Automation License Manager 5 (All versions < 5.3.4.4), Automation License Manager 6 (All versions < 6.0.1). A directory traversal vulnerability could allow a remote attacker to move arbitrary files, which can result in code execution, compromising confidentiality, integrity and availability of the system. Successful exploitation requires a network connection to the affected device. The attacker does not need privileges or special conditions of the system, but user interaction is required.
CVE-2018-11463 1 Siemens 10 Sinumerik 808d V4.7, Sinumerik 808d V4.7 Firmware, Sinumerik 808d V4.8 and 7 more 2019-10-09 4.6 MEDIUM 7.8 HIGH
A vulnerability has been identified in SINUMERIK 808D V4.7 (All versions), SINUMERIK 808D V4.8 (All versions), SINUMERIK 828D V4.7 (All versions < V4.7 SP6 HF1), SINUMERIK 840D sl V4.7 (All versions < V4.7 SP6 HF5), SINUMERIK 840D sl V4.8 (All versions < V4.8 SP3). A buffer overflow in the service command application could allow a local attacker to execute code with elevated privileges. The security vulnerability could be exploited by an attacker with local access to the affected systems. Successful exploitation requires user privileges but no user interaction. The vulnerability could allow an attacker to compromise confidentiality, integrity and availability of the system. At the time of advisory publication no public exploitation of this security vulnerability was known.
CVE-2018-11447 1 Siemens 2 Scalance M875, Scalance M875 Firmware 2019-10-09 6.8 MEDIUM 8.8 HIGH
A vulnerability has been identified in SCALANCE M875 (All versions). The web interface on port 443/tcp could allow a Cross-Site Request Forgery (CSRF) attack if an unsuspecting user is tricked into accessing a malicious link. Successful exploitation requires user interaction by an legitimate user, who must be authenticated to the web interface as administrative user. A successful attack could allow an attacker to interact with the web interface as an administrative user. This could allow the attacker to read or modify the device configuration, or to exploit other vulnerabilities that require authentication as administrative user. At the time of advisory publication no public exploitation of this security vulnerability was known.
CVE-2018-11466 1 Siemens 10 Sinumerik 808d V4.7, Sinumerik 808d V4.7 Firmware, Sinumerik 808d V4.8 and 7 more 2019-10-09 7.5 HIGH 9.8 CRITICAL
A vulnerability has been identified in SINUMERIK 808D V4.7 (All versions), SINUMERIK 808D V4.8 (All versions), SINUMERIK 828D V4.7 (All versions < V4.7 SP6 HF1), SINUMERIK 840D sl V4.7 (All versions < V4.7 SP6 HF5), SINUMERIK 840D sl V4.8 (All versions < V4.8 SP3). Specially crafted network packets sent to port 102/tcp (ISO-TSAP) could allow a remote attacker to either cause a Denial-of-Service condition of the integrated software firewall or allow to execute code in the context of the software firewall. The security vulnerability could be exploited by an attacker with network access to the affected systems on port 102/tcp. Successful exploitation requires no user privileges and no user interaction. The vulnerability could allow an attacker to compromise confidentiality, integrity and availability of the system. At the time of advisory publication no public exploitation of this security vulnerability was known
CVE-2018-11461 1 Siemens 10 Sinumerik 808d V4.7, Sinumerik 808d V4.7 Firmware, Sinumerik 808d V4.8 and 7 more 2019-10-09 4.6 MEDIUM 6.6 MEDIUM
A vulnerability has been identified in SINUMERIK 808D V4.7 (All versions), SINUMERIK 808D V4.8 (All versions), SINUMERIK 828D V4.7 (All versions < V4.7 SP6 HF1), SINUMERIK 840D sl V4.7 (All versions < V4.7 SP6 HF5), SINUMERIK 840D sl V4.8 (All versions < V4.8 SP3). A local attacker with user privileges could use the service command application for privilege escalation to an elevated user but not root. The security vulnerability could be exploited by an attacker with local access to the affected systems. Successful exploitation requires user privileges but no user interaction. The vulnerability could allow an attacker to compromise confidentiality, integrity and availability of the system. At the time of advisory publication no public exploitation of this security vulnerability was known.
CVE-2018-11464 1 Siemens 4 Sinumerik 828d, Sinumerik 828d Firmware, Sinumerik 840d Sl and 1 more 2019-10-09 4.3 MEDIUM 3.7 LOW
A vulnerability has been identified in SINUMERIK 828D V4.7 (All versions < V4.7 SP6 HF1), SINUMERIK 840D sl V4.7 (All versions < V4.7 SP6 HF5), SINUMERIK 840D sl V4.8 (All versions < V4.8 SP3). The integrated VNC server on port 5900/tcp of the affected products could allow a remote attacker to cause a Denial-of-Service condition of the VNC server. Please note that this vulnerability is only exploitable if port 5900/tcp is manually opened in the firewall configuration of network port X130. The security vulnerability could be exploited by an attacker with network access to the affected devices and port. Successful exploitation requires no privileges and no user interaction. The vulnerability could allow an attacker to compromise availability of the VNC server. At the time of advisory publication no public exploitation of this security vulnerability was known.
CVE-2018-11453 1 Siemens 2 Simatic Step 7 \(tia Portal\), Simatic Wincc \(tia Portal\) 2019-10-09 4.6 MEDIUM 7.8 HIGH
A vulnerability has been identified in SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V10, V11, V12 (All versions), SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V13 (All versions < V13 SP2 Update 2), SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V14 (All versions < V14 SP1 Update 6), SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V15 (All versions < V15 Update 2). Improper file permissions in the default installation of TIA Portal may allow an attacker with local file system access to insert specially crafted files which may prevent TIA Portal startup (Denial-of-Service) or lead to local code execution. No special privileges are required, but the victim needs to attempt to start TIA Portal after the manipulation.
CVE-2018-11460 1 Siemens 10 Sinumerik 808d V4.7, Sinumerik 808d V4.7 Firmware, Sinumerik 808d V4.8 and 7 more 2019-10-09 7.2 HIGH 7.8 HIGH
A vulnerability has been identified in SINUMERIK 808D V4.7 (All versions), SINUMERIK 808D V4.8 (All versions), SINUMERIK 828D V4.7 (All versions < V4.7 SP6 HF1), SINUMERIK 840D sl V4.7 (All versions < V4.7 SP6 HF5), SINUMERIK 840D sl V4.8 (All versions < V4.8 SP3). A local attacker with elevated user privileges (manufact) could modify a CRAMFS archive so that after reboot the system loads the modified CRAMFS file and attacker-controlled code is executed with root privileges. The security vulnerability could be exploited by an attacker with local access to the affected systems. Successful exploitation requires elevated user privileges (manufact) but no user interaction. The vulnerability could allow an attacker to compromise confidentiality, integrity and availability of the system. At the time of advisory publication no public exploitation of this security vulnerability was known.
CVE-2018-11458 1 Siemens 6 Sinumerik 828d V4.7, Sinumerik 828d V4.7 Firmware, Sinumerik 840d Sl V4.7 and 3 more 2019-10-09 9.3 HIGH 8.1 HIGH
A vulnerability has been identified in SINUMERIK 828D V4.7 (All versions < V4.7 SP6 HF1), SINUMERIK 840D sl V4.7 (All versions < V4.7 SP6 HF5), SINUMERIK 840D sl V4.8 (All versions < V4.8 SP3). The integrated VNC server on port 5900/tcp of the affected products could allow a remote attacker to execute code with privileged permissions on the system by sending specially crafted network requests to port 5900/tcp. Please note that this vulnerability is only exploitable if port 5900/tcp is manually opened in the firewall configuration of network port X130. The security vulnerability could be exploited by an attacker with network access to the affected devices and port. Successful exploitation requires no privileges and no user interaction. The vulnerability could allow an attacker to compromise confidentiality, integrity and availability of the VNC server. At the time of advisory publication no public exploitation of this security vulnerability was known.
CVE-2018-11459 1 Siemens 10 Sinumerik 808d V4.7, Sinumerik 808d V4.7 Firmware, Sinumerik 808d V4.8 and 7 more 2019-10-09 7.2 HIGH 7.8 HIGH
A vulnerability has been identified in SINUMERIK 808D V4.7 (All versions), SINUMERIK 808D V4.8 (All versions), SINUMERIK 828D V4.7 (All versions < V4.7 SP6 HF1), SINUMERIK 840D sl V4.7 (All versions < V4.7 SP6 HF5), SINUMERIK 840D sl V4.8 (All versions < V4.8 SP3). A local attacker could modify a user-writeable configuration file so that after reboot or manual initiation the system reloads the modified configuration file and attacker-controlled code is executed with elevated privileges. The security vulnerability could be exploited by an attacker with local access to the affected system. Successful exploitation requires user privileges but no user interaction. The vulnerability could allow an attacker to compromise confidentiality, integrity and availability of the system. At the time of advisory publication no public exploitation of this security vulnerability was known.
CVE-2018-11465 1 Siemens 10 Sinumerik 808d V4.7, Sinumerik 808d V4.7 Firmware, Sinumerik 808d V4.8 and 7 more 2019-10-09 7.2 HIGH 7.8 HIGH
A vulnerability has been identified in SINUMERIK 808D V4.7 (All versions), SINUMERIK 808D V4.8 (All versions), SINUMERIK 828D V4.7 (All versions < V4.7 SP6 HF1), SINUMERIK 840D sl V4.7 (All versions < V4.7 SP6 HF5), SINUMERIK 840D sl V4.8 (All versions < V4.8 SP3). A local attacker could use ioctl calls to do out of bounds reads, arbitrary writes, or execute code in kernel mode. The security vulnerability could be exploited by an attacker with local access to the affected systems. Successful exploitation requires user privileges but no user interaction. The vulnerability could allow an attacker to compromise confidentiality, integrity and availability of the system. At the time of advisory publication no public exploitation of this security vulnerability was known.
CVE-2017-9940 1 Siemens 1 Sipass Integrated 2019-10-09 5.5 MEDIUM 8.1 HIGH
A vulnerability was discovered in Siemens SiPass integrated (All versions before V2.70) that could allow an attacker with access to a low-privileged user account to read or write files on the file system of the SiPass integrated server over the network.
CVE-2017-9939 1 Siemens 1 Sipass Integrated 2019-10-09 7.5 HIGH 9.8 CRITICAL
A vulnerability was discovered in Siemens SiPass integrated (All versions before V2.70) that could allow an attacker with network access to the SiPass integrated server to bypass the authentication mechanism and perform administrative operations.
CVE-2017-9942 1 Siemens 1 Sipass Integrated 2019-10-09 2.1 LOW 7.8 HIGH
A vulnerability was discovered in Siemens SiPass integrated (All versions before V2.70) that could allow an attacker with local access to the SiPass integrated server or SiPass integrated client to potentially obtain credentials from the systems.
CVE-2017-9944 1 Siemens 2 7kt Pac1200 Data Manager, 7kt Pac1200 Data Manager Firmware 2019-10-09 10.0 HIGH 9.8 CRITICAL
A vulnerability has been identified in Siemens 7KT PAC1200 data manager (7KT1260) in all versions < V2.03. The integrated web server (port 80/tcp) of the affected devices could allow an unauthenticated remote attacker to perform administrative operations over the network.
CVE-2017-9941 1 Siemens 1 Sipass Integrated 2019-10-09 5.8 MEDIUM 7.4 HIGH
A vulnerability was discovered in Siemens SiPass integrated (All versions before V2.70) that could allow an attacker in a Man-in-the-Middle position between the SiPass integrated server and SiPass integrated clients to read or modify the network communication.