Filtered by vendor Rockwellautomation
Subscribe
Total
308 CVE
CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
---|---|---|---|---|---|
CVE-2023-2637 | 1 Rockwellautomation | 2 Factorytalk Policy Manager, Factorytalk System Services | 2023-06-26 | N/A | 8.2 HIGH |
Rockwell Automation's FactoryTalk System Services uses a hard-coded cryptographic key to generate administrator cookies. Hard-coded cryptographic key may lead to privilege escalation. This vulnerability may allow a local, authenticated non-admin user to generate an invalid administrator cookie giving them administrative privileges to the FactoryTalk Policy Manger database. This may allow the threat actor to make malicious changes to the database that will be deployed when a legitimate FactoryTalk Policy Manager user deploys a security policy model. User interaction is required for this vulnerability to be successfully exploited. | |||||
CVE-2023-2638 | 1 Rockwellautomation | 2 Factorytalk Policy Manager, Factorytalk System Services | 2023-06-26 | N/A | 5.0 MEDIUM |
Rockwell Automation's FactoryTalk System Services does not verify that a backup configuration archive is password protected. Improper authorization in FTSSBackupRestore.exe may lead to the loading of malicious configuration archives. This vulnerability may allow a local, authenticated non-admin user to craft a malicious backup archive, without password protection, that will be loaded by FactoryTalk System Services as a valid backup when a restore procedure takes places. User interaction is required for this vulnerability to be successfully exploited. | |||||
CVE-2023-2639 | 1 Rockwellautomation | 2 Factorytalk Policy Manager, Factorytalk System Services | 2023-06-26 | N/A | 4.7 MEDIUM |
The underlying feedback mechanism of Rockwell Automation's FactoryTalk System Services that transfers the FactoryTalk Policy Manager rules to relevant devices on the network does not verify that the origin of the communication is from a legitimate local client device. This may allow a threat actor to craft a malicious website that, when visited, will send a malicious script that can connect to the local WebSocket endpoint and wait for events as if it was a valid client device. If successfully exploited, this would allow a threat actor to receive information including whether FactoryTalk Policy Manager is installed and potentially the entire security policy. | |||||
CVE-2023-2778 | 1 Rockwellautomation | 1 Factorytalk Transaction Manager | 2023-06-26 | N/A | 7.5 HIGH |
A denial-of-service vulnerability exists in Rockwell Automation FactoryTalk Transaction Manager. This vulnerability can be exploited by sending a modified packet to port 400. If exploited, the application could potentially crash or experience a high CPU or memory usage condition, causing intermittent application functionality issues. The application would need to be restarted to recover from the DoS. | |||||
CVE-2019-10952 | 1 Rockwellautomation | 8 Armor Compact Guardlogix 5370, Armor Compact Guardlogix 5370 Firmware, Compactlogix 5370 L1 and 5 more | 2023-06-20 | 7.5 HIGH | 9.8 CRITICAL |
An attacker could send a crafted HTTP/HTTPS request to render the web server unavailable and/or lead to remote code execution caused by a stack-based buffer overflow vulnerability. A cold restart is required for recovering CompactLogix 5370 L1, L2, and L3 Controllers, Compact GuardLogix 5370 controllers, and Armor Compact GuardLogix 5370 Controllers Versions 20 - 30 and earlier. | |||||
CVE-2019-10954 | 1 Rockwellautomation | 10 Armor Compact Guardlogix 5370, Armor Compact Guardlogix 5370 Firmware, Compact Guardlogix 5370 and 7 more | 2023-06-20 | 7.8 HIGH | 7.5 HIGH |
An attacker could send crafted SMTP packets to cause a denial-of-service condition where the controller enters a major non-recoverable faulted state (MNRF) in CompactLogix 5370 L1, L2, and L3 Controllers, Compact GuardLogix 5370 controllers, and Armor Compact GuardLogix 5370 Controllers Versions 20 - 30 and earlier. | |||||
CVE-2016-2279 | 1 Rockwellautomation | 46 Compactlogix 1756-en2f Series A, Compactlogix 1756-en2f Series A Firmware, Compactlogix 1756-en2f Series B and 43 more | 2023-05-23 | 4.3 MEDIUM | 6.1 MEDIUM |
Cross-site scripting (XSS) vulnerability in the web server in Rockwell Automation Allen-Bradley CompactLogix 1769-L* before 28.011+ allows remote attackers to inject arbitrary web script or HTML via unspecified vectors. | |||||
CVE-2023-1834 | 1 Rockwellautomation | 2 Kinetix 5500, Kinetix 5500 Firmware | 2023-05-22 | N/A | 9.1 CRITICAL |
Rockwell Automation was made aware that Kinetix 5500 drives, manufactured between May 2022 and January 2023, and are running v7.13 may have the telnet and FTP ports open by default. This could potentially allow attackers unauthorized access to the device through the open ports. | |||||
CVE-2023-2443 | 1 Rockwellautomation | 1 Thinmanager | 2023-05-20 | N/A | 7.5 HIGH |
Rockwell Automation ThinManager product allows the use of medium strength ciphers. If the client requests an insecure cipher, a malicious actor could potentially decrypt traffic sent between the client and server API. | |||||
CVE-2023-2444 | 1 Rockwellautomation | 1 Factorytalk Vantagepoint | 2023-05-20 | N/A | 8.8 HIGH |
A cross site request forgery vulnerability exists in Rockwell Automation's FactoryTalk Vantagepoint. This vulnerability can be exploited in two ways. If an attacker sends a malicious link to a computer that is on the same domain as the FactoryTalk Vantagepoint server and a user clicks the link, the attacker could impersonate the legitimate user and send requests to the affected product. Additionally, if an attacker sends an untrusted link to a computer that is not on the same domain as the server and a user opens the FactoryTalk Vantagepoint website, enters credentials for the FactoryTalk Vantagepoint server, and clicks on the malicious link a cross site request forgery attack would be successful as well. | |||||
CVE-2017-12093 | 1 Rockwellautomation | 2 Micrologix 1400, Micrologix 1400 B Firmware | 2023-01-28 | 5.0 MEDIUM | 5.3 MEDIUM |
An exploitable insufficient resource pool vulnerability exists in the session communication functionality of Allen Bradley Micrologix 1400 Series B Firmware 21.2 and before. A specially crafted stream of packets can cause a flood of the session resource pool resulting in legitimate connections to the PLC being disconnected. An attacker can send unauthenticated packets to trigger this vulnerability. | |||||
CVE-2017-14468 | 1 Rockwellautomation | 2 Micrologix 1400, Micrologix 1400 B Firmware | 2022-12-14 | 7.5 HIGH | 9.8 CRITICAL |
An exploitable access control vulnerability exists in the data, program, and function file permissions functionality of Allen Bradley Micrologix 1400 Series B FRN 21.2 and before. A specially crafted packet can cause a read or write operation resulting in disclosure of sensitive information, modification of settings, or modification of ladder logic. An attacker can send unauthenticated packets to trigger this vulnerability. Required Keyswitch State: REMOTE or PROG Description: This ability is leveraged in a larger exploit to flash custom firmware. | |||||
CVE-2017-14467 | 1 Rockwellautomation | 2 Micrologix 1400, Micrologix 1400 B Firmware | 2022-12-14 | 7.5 HIGH | 9.8 CRITICAL |
An exploitable access control vulnerability exists in the data, program, and function file permissions functionality of Allen Bradley Micrologix 1400 Series B FRN 21.2 and before. A specially crafted packet can cause a read or write operation resulting in disclosure of sensitive information, modification of settings, or modification of ladder logic. An attacker can send unauthenticated packets to trigger this vulnerability. Required Keyswitch State: REMOTE Description: Live rung edits are able to be made by an unauthenticated user allowing for addition, deletion, or modification of existing ladder logic. Additionally, faults and cpu state modification can be triggered if specific ladder logic is used. | |||||
CVE-2017-14465 | 1 Rockwellautomation | 2 Micrologix 1400, Micrologix 1400 B Firmware | 2022-12-14 | 7.5 HIGH | 9.8 CRITICAL |
An exploitable access control vulnerability exists in the data, program, and function file permissions functionality of Allen Bradley Micrologix 1400 Series B FRN 21.2 and before. A specially crafted packet can cause a read or write operation resulting in disclosure of sensitive information, modification of settings, or modification of ladder logic. An attacker can send unauthenticated packets to trigger this vulnerability. Required Keyswitch State: REMOTE Description: Any input or output can be forced, causing unpredictable activity from the PLC. | |||||
CVE-2017-14466 | 1 Rockwellautomation | 2 Micrologix 1400, Micrologix 1400 B Firmware | 2022-12-14 | 7.5 HIGH | 9.8 CRITICAL |
An exploitable access control vulnerability exists in the data, program, and function file permissions functionality of Allen Bradley Micrologix 1400 Series B FRN 21.2 and before. A specially crafted packet can cause a read or write operation resulting in disclosure of sensitive information, modification of settings, or modification of ladder logic. An attacker can send unauthenticated packets to trigger this vulnerability. Required Keyswitch State: REMOTE or PROG Description: The filetype 0x03 allows users write access, allowing the ability to overwrite the Master Password value stored in the file. | |||||
CVE-2017-14464 | 1 Rockwellautomation | 2 Micrologix 1400, Micrologix 1400 B Firmware | 2022-12-14 | 7.5 HIGH | 9.8 CRITICAL |
An exploitable access control vulnerability exists in the data, program, and function file permissions functionality of Allen Bradley Micrologix 1400 Series B FRN 21.2 and before. A specially crafted packet can cause a read or write operation resulting in disclosure of sensitive information, modification of settings, or modification of ladder logic. An attacker can send unauthenticated packets to trigger this vulnerability.Required Keyswitch State: REMOTE or PROG Associated Fault Code: 0001 Fault Type: Non-User Description: A fault state can be triggered by setting the NVRAM/memory module user program mismatch bit (S2:9) when a memory module is NOT installed. | |||||
CVE-2017-14463 | 1 Rockwellautomation | 2 Micrologix 1400, Micrologix 1400 B Firmware | 2022-12-14 | 7.5 HIGH | 9.8 CRITICAL |
An exploitable access control vulnerability exists in the data, program, and function file permissions functionality of Allen Bradley Micrologix 1400 Series B FRN 21.2 and before. A specially crafted packet can cause a read or write operation resulting in disclosure of sensitive information, modification of settings, or modification of ladder logic. An attacker can send unauthenticated packets to trigger this vulnerability. Required Keyswitch State: REMOTE or PROG Associated Fault Code: 0012 Fault Type: Non-User Description: A fault state can be triggered by overwriting the ladder logic data file (type 0x22 number 0x02) with null values. | |||||
CVE-2017-14462 | 1 Rockwellautomation | 2 Micrologix 1400, Micrologix 1400 B Firmware | 2022-12-14 | 7.5 HIGH | 9.8 CRITICAL |
An exploitable access control vulnerability exists in the data, program, and function file permissions functionality of Allen Bradley Micrologix 1400 Series B FRN 21.2 and before. A specially crafted packet can cause a read or write operation resulting in disclosure of sensitive information, modification of settings, or modification of ladder logic. An attacker can send unauthenticated packets to trigger this vulnerability. Required Keyswitch State: REMOTE or PROG (also RUN for some) Description: Allows an attacker to enable SNMP, Modbus, DNP, and any other features in the channel configuration. Also allows attackers to change network parameters, such as IP address, name server, and domain name. | |||||
CVE-2021-32926 | 1 Rockwellautomation | 4 Micro800, Micro800 Firmware, Micrologix 1400 and 1 more | 2022-10-25 | 5.0 MEDIUM | 7.5 HIGH |
When an authenticated password change request takes place, this vulnerability could allow the attacker to intercept the message that includes the legitimate, new password hash and replace it with an illegitimate hash. The user would no longer be able to authenticate to the controller (Micro800: All versions, MicroLogix 1400: Version 21 and later) causing a denial-of-service condition | |||||
CVE-2020-25184 | 3 Rockwellautomation, Schneider-electric, Xylem | 31 Aadvance Controller, Isagraf Free Runtime, Isagraf Runtime and 28 more | 2022-10-21 | 2.1 LOW | 5.5 MEDIUM |
Rockwell Automation ISaGRAF Runtime Versions 4.x and 5.x stores the password in plaintext in a file that is in the same directory as the executable file. ISaGRAF Runtime reads the file and saves the data in a variable without any additional modification. A local, unauthenticated attacker could compromise the user passwords, resulting in information disclosure. |