Filtered by vendor Moxa
Subscribe
Total
282 CVE
CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
---|---|---|---|---|---|
CVE-2019-9095 | 1 Moxa | 12 Mb3170, Mb3170 Firmware, Mb3180 and 9 more | 2021-07-21 | 5.0 MEDIUM | 9.8 CRITICAL |
An issue was discovered on Moxa MGate MB3170 and MB3270 devices before 4.1, MB3280 and MB3480 devices before 3.1, MB3660 devices before 2.3, and MB3180 devices before 2.1. An attacker may be able to intercept weakly encrypted passwords and gain administrative access. | |||||
CVE-2019-9104 | 1 Moxa | 12 Mb3170, Mb3170 Firmware, Mb3180 and 9 more | 2021-07-21 | 5.0 MEDIUM | 7.5 HIGH |
An issue was discovered on Moxa MGate MB3170 and MB3270 devices before 4.1, MB3280 and MB3480 devices before 3.1, MB3660 devices before 2.3, and MB3180 devices before 2.1. The application's configuration file contains parameters that represent passwords in cleartext. | |||||
CVE-2019-9102 | 1 Moxa | 12 Mb3170, Mb3170 Firmware, Mb3180 and 9 more | 2021-07-21 | 6.8 MEDIUM | 8.8 HIGH |
An issue was discovered on Moxa MGate MB3170 and MB3270 devices before 4.1, MB3280 and MB3480 devices before 3.1, MB3660 devices before 2.3, and MB3180 devices before 2.1. A predictable mechanism of generating tokens allows remote attackers to bypass the cross-site request forgery (CSRF) protection mechanism. | |||||
CVE-2016-5804 | 1 Moxa | 10 Mgate Mb3170, Mgate Mb3170 Firmware, Mgate Mb3180 and 7 more | 2021-07-16 | 5.0 MEDIUM | 9.8 CRITICAL |
Moxa MGate MB3180 before 1.8, MGate MB3280 before 2.7, MGate MB3480 before 2.6, MGate MB3170 before 2.5, and MGate MB3270 before 2.7 use weak encryption, which allows remote attackers to bypass authentication via a brute-force series of guesses for a parameter value. | |||||
CVE-2021-33824 | 1 Moxa | 2 Mgate Mb3180, Mgate Mb3180 Firmware | 2021-06-24 | 5.0 MEDIUM | 7.5 HIGH |
An issue was discovered on MOXA Mgate MB3180 Version 2.1 Build 18113012. Attackers can use slowhttptest tool to send incomplete HTTP request, which could make server keep waiting for the packet to finish the connection, until its resource exhausted. Then the web server is denial-of-service. | |||||
CVE-2016-8359 | 1 Moxa | 19 Iologik E1200 Series Firmware, Iologik E1210, Iologik E1211 and 16 more | 2021-05-19 | 4.3 MEDIUM | 6.1 MEDIUM |
An issue was discovered in Moxa ioLogik E1210, firmware Version V2.4 and prior, ioLogik E1211, firmware Version V2.3 and prior, ioLogik E1212, firmware Version V2.4 and prior, ioLogik E1213, firmware Version V2.5 and prior, ioLogik E1214, firmware Version V2.4 and prior, ioLogik E1240, firmware Version V2.3 and prior, ioLogik E1241, firmware Version V2.4 and prior, ioLogik E1242, firmware Version V2.4 and prior, ioLogik E1260, firmware Version V2.4 and prior, ioLogik E1262, firmware Version V2.4 and prior, ioLogik E2210, firmware versions prior to V3.13, ioLogik E2212, firmware versions prior to V3.14, ioLogik E2214, firmware versions prior to V3.12, ioLogik E2240, firmware versions prior to V3.12, ioLogik E2242, firmware versions prior to V3.12, ioLogik E2260, firmware versions prior to V3.13, and ioLogik E2262, firmware versions prior to V3.12. The web application fails to sanitize user input, which may allow an attacker to inject script or execute arbitrary code (CROSS-SITE SCRIPTING). | |||||
CVE-2016-8372 | 1 Moxa | 19 Iologik E1200 Series Firmware, Iologik E1210, Iologik E1211 and 16 more | 2021-05-19 | 4.3 MEDIUM | 8.1 HIGH |
An issue was discovered in Moxa ioLogik E1210, firmware Version V2.4 and prior, ioLogik E1211, firmware Version V2.3 and prior, ioLogik E1212, firmware Version V2.4 and prior, ioLogik E1213, firmware Version V2.5 and prior, ioLogik E1214, firmware Version V2.4 and prior, ioLogik E1240, firmware Version V2.3 and prior, ioLogik E1241, firmware Version V2.4 and prior, ioLogik E1242, firmware Version V2.4 and prior, ioLogik E1260, firmware Version V2.4 and prior, ioLogik E1262, firmware Version V2.4 and prior, ioLogik E2210, firmware versions prior to V3.13, ioLogik E2212, firmware versions prior to V3.14, ioLogik E2214, firmware versions prior to V3.12, ioLogik E2240, firmware versions prior to V3.12, ioLogik E2242, firmware versions prior to V3.12, ioLogik E2260, firmware versions prior to V3.13, and ioLogik E2262, firmware versions prior to V3.12. A password is transmitted in a format that is not sufficiently secure. | |||||
CVE-2016-8379 | 1 Moxa | 19 Iologik E1200 Series Firmware, Iologik E1210, Iologik E1211 and 16 more | 2021-05-19 | 4.3 MEDIUM | 8.1 HIGH |
An issue was discovered in Moxa ioLogik E1210, firmware Version V2.4 and prior, ioLogik E1211, firmware Version V2.3 and prior, ioLogik E1212, firmware Version V2.4 and prior, ioLogik E1213, firmware Version V2.5 and prior, ioLogik E1214, firmware Version V2.4 and prior, ioLogik E1240, firmware Version V2.3 and prior, ioLogik E1241, firmware Version V2.4 and prior, ioLogik E1242, firmware Version V2.4 and prior, ioLogik E1260, firmware Version V2.4 and prior, ioLogik E1262, firmware Version V2.4 and prior, ioLogik E2210, firmware versions prior to V3.13, ioLogik E2212, firmware versions prior to V3.14, ioLogik E2214, firmware versions prior to V3.12, ioLogik E2240, firmware versions prior to V3.12, ioLogik E2242, firmware versions prior to V3.12, ioLogik E2260, firmware versions prior to V3.13, and ioLogik E2262, firmware versions prior to V3.12. Users are restricted to using short passwords. | |||||
CVE-2016-8350 | 1 Moxa | 19 Iologik E1200 Series Firmware, Iologik E1210, Iologik E1211 and 16 more | 2021-05-19 | 6.8 MEDIUM | 6.3 MEDIUM |
An issue was discovered in Moxa ioLogik E1210, firmware Version V2.4 and prior, ioLogik E1211, firmware Version V2.3 and prior, ioLogik E1212, firmware Version V2.4 and prior, ioLogik E1213, firmware Version V2.5 and prior, ioLogik E1214, firmware Version V2.4 and prior, ioLogik E1240, firmware Version V2.3 and prior, ioLogik E1241, firmware Version V2.4 and prior, ioLogik E1242, firmware Version V2.4 and prior, ioLogik E1260, firmware Version V2.4 and prior, ioLogik E1262, firmware Version V2.4 and prior, ioLogik E2210, firmware versions prior to V3.13, ioLogik E2212, firmware versions prior to V3.14, ioLogik E2214, firmware versions prior to V3.12, ioLogik E2240, firmware versions prior to V3.12, ioLogik E2242, firmware versions prior to V3.12, ioLogik E2260, firmware versions prior to V3.13, and ioLogik E2262, firmware versions prior to V3.12. The web application may not sufficiently verify whether a request was provided by a valid user (CROSS-SITE REQUEST FORGERY). | |||||
CVE-2016-2283 | 1 Moxa | 16 Ioadmin Firmware, Iologik E2210, Iologik E2210-t and 13 more | 2021-05-19 | 5.0 MEDIUM | 5.3 MEDIUM |
Moxa ioLogik E2200 devices before 3.12 and ioAdmin Configuration Utility before 3.18 do not properly encrypt data, which makes it easier for remote attackers to obtain the associated cleartext via unspecified vectors. | |||||
CVE-2016-2282 | 1 Moxa | 16 Ioadmin Firmware, Iologik E2210, Iologik E2210-t and 13 more | 2021-05-19 | 5.0 MEDIUM | 5.3 MEDIUM |
Moxa ioLogik E2200 devices before 3.12 and ioAdmin Configuration Utility before 3.18 do not properly encrypt credentials, which makes it easier for remote attackers to obtain the associated cleartext via unspecified vectors. | |||||
CVE-2021-25849 | 1 Moxa | 32 Vport 06ec-2v26m, Vport 06ec-2v26m Firmware, Vport 06ec-2v36m-ct and 29 more | 2021-05-18 | 7.8 HIGH | 7.5 HIGH |
An integer underflow was discovered in userdisk/vport_lldpd in Moxa Camera VPort 06EC-2V Series, version 1.1, improper validation of the PortID TLV leads to Denial of Service via a crafted lldp packet. | |||||
CVE-2021-25847 | 1 Moxa | 32 Vport 06ec-2v26m, Vport 06ec-2v26m Firmware, Vport 06ec-2v36m-ct and 29 more | 2021-05-18 | 8.5 HIGH | 9.1 CRITICAL |
Improper validation of the length field of LLDP-MED TLV in userdisk/vport_lldpd in Moxa Camera VPort 06EC-2V Series, version 1.1, allows information disclosure to attackers due to controllable loop counter variable via a crafted lldp packet. | |||||
CVE-2021-25848 | 1 Moxa | 32 Vport 06ec-2v26m, Vport 06ec-2v26m Firmware, Vport 06ec-2v36m-ct and 29 more | 2021-05-18 | 8.5 HIGH | 9.1 CRITICAL |
Improper validation of the length field of LLDP-MED TLV in userdisk/vport_lldpd in Moxa Camera VPort 06EC-2V Series, version 1.1, allows information disclosure to attackers due to using fixed loop counter variable without checking the actual available length via a crafted lldp packet. | |||||
CVE-2021-25846 | 1 Moxa | 32 Vport 06ec-2v26m, Vport 06ec-2v26m Firmware, Vport 06ec-2v36m-ct and 29 more | 2021-05-18 | 7.8 HIGH | 7.5 HIGH |
Improper validation of the ChassisID TLV in userdisk/vport_lldpd in Moxa Camera VPort 06EC-2V Series, version 1.1, allows attackers to cause a denial of service due to a negative number passed to the memcpy function via a crafted lldp packet. | |||||
CVE-2021-25845 | 1 Moxa | 32 Vport 06ec-2v26m, Vport 06ec-2v26m Firmware, Vport 06ec-2v36m-ct and 29 more | 2021-05-18 | 5.0 MEDIUM | 7.5 HIGH |
Improper validation of the ChassisID TLV in userdisk/vport_lldpd in Moxa Camera VPort 06EC-2V Series, version 1.1, allows attackers to cause a denial of service due to a NULL pointer dereference via a crafted lldp packet. | |||||
CVE-2020-28144 | 1 Moxa | 16 Edr-810-2gsfp, Edr-810-2gsfp-t, Edr-810-2gsfp-t Firmware and 13 more | 2021-02-05 | 7.5 HIGH | 9.8 CRITICAL |
Certain Moxa Inc products are affected by an improper restriction of operations in EDR-G903 Series Firmware Version 5.5 or lower, EDR-G902 Series Firmware Version 5.5 or lower, and EDR-810 Series Firmware Version 5.6 or lower. Crafted requests sent to the device may allow remote arbitrary code execution. | |||||
CVE-2020-25153 | 1 Moxa | 2 Nport Iaw5000a-i\/o, Nport Iaw5000a-i\/o Firmware | 2020-12-23 | 5.0 MEDIUM | 7.5 HIGH |
The built-in web service for MOXA NPort IAW5000A-I/O firmware version 2.1 or lower does not require users to have strong passwords. | |||||
CVE-2020-25190 | 1 Moxa | 2 Nport Iaw5000a-i\/o, Nport Iaw5000a-i\/o Firmware | 2020-12-23 | 5.0 MEDIUM | 9.8 CRITICAL |
The built-in WEB server for MOXA NPort IAW5000A-I/O firmware version 2.1 or lower stores and transmits the credentials of third-party services in cleartext. | |||||
CVE-2020-25198 | 1 Moxa | 2 Nport Iaw5000a-i\/o, Nport Iaw5000a-i\/o Firmware | 2020-12-23 | 6.8 MEDIUM | 8.8 HIGH |
The built-in WEB server for MOXA NPort IAW5000A-I/O firmware version 2.1 or lower has incorrectly implemented protections from session fixation, which may allow an attacker to gain access to a session and hijack it by stealing the user’s cookies. |