Filtered by vendor Siemens
Subscribe
Total
1983 CVE
CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
---|---|---|---|---|---|
CVE-2021-40355 | 1 Siemens | 1 Teamcenter Visualization | 2021-09-28 | 6.5 MEDIUM | 8.8 HIGH |
A vulnerability has been identified in Teamcenter V12.4 (All versions < V12.4.0.8), Teamcenter V13.0 (All versions < V13.0.0.7), Teamcenter V13.1 (All versions < V13.1.0.5), Teamcenter V13.2 (All versions < 13.2.0.2). The affected application contains Insecure Direct Object Reference (IDOR) vulnerability that allows an attacker to use user-supplied input to access objects directly. | |||||
CVE-2021-37181 | 1 Siemens | 3 Cerberus Dms, Desigo Cc, Desigo Cc Compact | 2021-09-24 | 7.5 HIGH | 10.0 CRITICAL |
A vulnerability has been identified in Cerberus DMS V4.0 (All versions), Cerberus DMS V4.1 (All versions), Cerberus DMS V4.2 (All versions), Cerberus DMS V5.0 (All versions < v5.0 QU1), Desigo CC Compact V4.0 (All versions), Desigo CC Compact V4.1 (All versions), Desigo CC Compact V4.2 (All versions), Desigo CC Compact V5.0 (All versions < V5.0 QU1), Desigo CC V4.0 (All versions), Desigo CC V4.1 (All versions), Desigo CC V4.2 (All versions), Desigo CC V5.0 (All versions < V5.0 QU1). The application deserialises untrusted data without sufficient validations, that could result in an arbitrary deserialization. This could allow an unauthenticated attacker to execute code in the affected system. The CCOM communication component used for Windows App / Click-Once and IE Web / XBAP client connectivity are affected by the vulnerability. | |||||
CVE-2021-37201 | 1 Siemens | 1 Sinec Network Management System | 2021-09-24 | 6.8 MEDIUM | 8.8 HIGH |
A vulnerability has been identified in SINEC NMS (All versions < V1.0 SP1). The web interface of affected devices is vulnerable to a Cross-Site Request Forgery (CSRF) attack. This could allow an attacker to manipulate the SINEC NMS configuration by tricking an unsuspecting user with administrative privileges to click on a malicious link. | |||||
CVE-2021-37200 | 1 Siemens | 1 Sinec Network Management System | 2021-09-24 | 4.0 MEDIUM | 7.7 HIGH |
A vulnerability has been identified in SINEC NMS (All versions < V1.0 SP1). An attacker with access to the webserver of an affected system could download arbitrary files from the underlying filesystem by sending a specially crafted HTTP request. | |||||
CVE-2021-37184 | 1 Siemens | 1 Industrial Edge Management | 2021-09-24 | 6.8 MEDIUM | 9.8 CRITICAL |
A vulnerability has been identified in Industrial Edge Management (All versions < V1.3). An unauthenticated attacker could change the the password of any user in the system under certain circumstances. With this an attacker could impersonate any valid user on an affected system. | |||||
CVE-2021-37176 | 1 Siemens | 1 Simcenter Femap | 2021-09-23 | 4.3 MEDIUM | 3.3 LOW |
A vulnerability has been identified in Simcenter Femap V2020.2 (All versions), Simcenter Femap V2021.1 (All versions). The femap.exe application lacks proper validation of user-supplied data when parsing modfem files. This could result in an out of bounds read past the end of an allocated buffer. An attacker could leverage this vulnerability to leak information in the context of the current process. (ZDI-CAN-14260) | |||||
CVE-2021-37174 | 1 Siemens | 20 Ruggedcom Rox Mx5000, Ruggedcom Rox Mx5000 Firmware, Ruggedcom Rox Rx1400 and 17 more | 2021-09-23 | 9.0 HIGH | 8.8 HIGH |
A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions < V2.14.1), RUGGEDCOM ROX RX1400 (All versions < V2.14.1), RUGGEDCOM ROX RX1500 (All versions < V2.14.1), RUGGEDCOM ROX RX1501 (All versions < V2.14.1), RUGGEDCOM ROX RX1510 (All versions < V2.14.1), RUGGEDCOM ROX RX1511 (All versions < V2.14.1), RUGGEDCOM ROX RX1512 (All versions < V2.14.1), RUGGEDCOM ROX RX1524 (All versions < V2.14.1), RUGGEDCOM ROX RX1536 (All versions < V2.14.1), RUGGEDCOM ROX RX5000 (All versions < V2.14.1). The affected devices have a privilege escalation vulnerability, if exploited, an attacker could gain root user access. | |||||
CVE-2021-25665 | 1 Siemens | 1 Simcenter Star-ccm\+ | 2021-09-23 | 6.8 MEDIUM | 7.8 HIGH |
A vulnerability has been identified in Simcenter STAR-CCM+ Viewer (All versions < V2021.2.1). The starview+.exe application lacks proper validation of user-supplied data when parsing scene files. This could result in an out of bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-13700) | |||||
CVE-2019-10941 | 1 Siemens | 1 Sinema Server | 2021-09-23 | 5.0 MEDIUM | 5.3 MEDIUM |
A vulnerability has been identified in SINEMA Server (All versions < V14 SP3). Missing authentication for functionality that requires administrative user identity could allow an attacker to obtain encoded system configuration backup files. This is only possible through network access to the affected system, and successful exploitation requires no system privileges. | |||||
CVE-2007-1913 | 8 Apple, Hp, Ibm and 5 more | 11 Macos, Hp-ux, Tru64 and 8 more | 2021-09-22 | 5.0 MEDIUM | N/A |
The TRUSTED_SYSTEM_SECURITY function in the SAP RFC Library 6.40 and 7.00 before 20061211 allows remote attackers to verify the existence of users and groups on systems and domains via unspecified vectors, a different vulnerability than CVE-2006-6010. NOTE: This information is based upon a vague initial disclosure. Details will be updated after the grace period has ended. | |||||
CVE-2007-1915 | 7 Apple, Hp, Ibm and 4 more | 10 Macos, Hp-ux, Tru64 and 7 more | 2021-09-22 | 7.5 HIGH | N/A |
Buffer overflow in the RFC_START_PROGRAM function in the SAP RFC Library 6.40 and 7.00 before 20061211 allows remote attackers to execute arbitrary code via unspecified vectors. NOTE: This information is based upon a vague initial disclosure. Details will be updated after the grace period has ended. | |||||
CVE-2007-1918 | 8 Apple, Hp, Ibm and 5 more | 11 Macos, Hp-ux, Tru64 and 8 more | 2021-09-22 | 5.0 MEDIUM | N/A |
The RFC_SET_REG_SERVER_PROPERTY function in the SAP RFC Library 6.40 and 7.00 before 20070109 implements an option for exclusive access to an RFC server, which allows remote attackers to cause a denial of service (client lockout) via unspecified vectors. NOTE: This information is based upon a vague initial disclosure. Details will be updated after the grace period has ended. | |||||
CVE-2007-1917 | 8 Apple, Hp, Ibm and 5 more | 11 Macos, Hp-ux, Tru64 and 8 more | 2021-09-22 | 10.0 HIGH | N/A |
Buffer overflow in the SYSTEM_CREATE_INSTANCE function in the SAP RFC Library 6.40 and 7.00 before 20061211 allows remote attackers to execute arbitrary code via unspecified vectors. NOTE: This information is based upon a vague initial disclosure. Details will be updated after the grace period has ended. | |||||
CVE-2007-1916 | 8 Apple, Hp, Ibm and 5 more | 11 Macos, Hp-ux, Tru64 and 8 more | 2021-09-22 | 10.0 HIGH | N/A |
Buffer overflow in the RFC_START_GUI function in the SAP RFC Library 6.40 and 7.00 before 20061211 allows remote attackers to execute arbitrary code via unspecified vectors. NOTE: This information is based upon a vague initial disclosure. Details will be updated after the grace period has ended. | |||||
CVE-2021-31342 | 1 Siemens | 4 Solid Edge Se2020, Solid Edge Se2020 Firmware, Solid Edge Se2021 and 1 more | 2021-09-21 | 6.8 MEDIUM | 8.8 HIGH |
The ugeom2d.dll library in all versions of Solid Edge SE2020 before 2020MP14 and all versions of Solid Edge SE2021 before SE2021MP5 lack proper validation of user-supplied data when parsing DFT files. This could result in an out-of-bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. | |||||
CVE-2021-31343 | 1 Siemens | 4 Solid Edge Se2020, Solid Edge Se2020 Firmware, Solid Edge Se2021 and 1 more | 2021-09-21 | 6.8 MEDIUM | 8.8 HIGH |
The jutil.dll library in all versions of Solid Edge SE2020 before 2020MP14 and all versions of Solid Edge SE2021 before SE2021MP5 lack proper validation of user-supplied data when parsing DFT files. This could result in an out-of-bounds write past the end of an allocation structure. An attacker could leverage this vulnerability to execute code in the context of the current process. | |||||
CVE-2021-33738 | 1 Siemens | 2 Jt2go, Teamcenter Visualization | 2021-09-21 | 4.3 MEDIUM | 3.3 LOW |
A vulnerability has been identified in JT2Go (All versions < V13.2.0.2), Teamcenter Visualization (All versions < V13.2.0.2). The plmxmlAdapterSE70.dll library in affected applications lacks proper validation of user-supplied data when parsing PAR files. This could result in an out of bounds read past the end of an allocated buffer. An attacker could leverage this vulnerability to leak information in the context of the current process. (ZDI-CAN-13405) | |||||
CVE-2021-34318 | 1 Siemens | 2 Jt2go, Teamcenter Visualization | 2021-09-20 | 6.8 MEDIUM | 7.8 HIGH |
A vulnerability has been identified in JT2Go (All versions < V13.2), Teamcenter Visualization (All versions < V13.2). The BMP_loader.dll library in affected applications lacks proper validation of user-supplied data when parsing PCT files. This could result in an out of bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-13403) | |||||
CVE-2021-34330 | 1 Siemens | 2 Jt2go, Teamcenter Visualization | 2021-09-20 | 6.8 MEDIUM | 7.8 HIGH |
A vulnerability has been identified in JT2Go (All versions < V13.2), Teamcenter Visualization (All versions < V13.2). The Jt981.dll library in affected applications lacks proper validation of user-supplied data prior to performing further free operations on an object when parsing JT files. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-13430) | |||||
CVE-2019-10940 | 1 Siemens | 1 Sinema Server | 2021-09-20 | 9.0 HIGH | 9.9 CRITICAL |
A vulnerability has been identified in SINEMA Server (All versions < V14.0 SP2 Update 1). Incorrect session validation could allow an attacker with a valid session, with low privileges, to perform firmware updates and other administrative operations on connected devices. The security vulnerability could be exploited by an attacker with network access to the affected system. An attacker must have access to a low privileged account in order to exploit the vulnerability. An attacker could use the vulnerability to compromise confidentiality, integrity, and availability of the affected system and underlying components. At the time of advisory publication no public exploitation of this security vulnerability was known. |