Filtered by vendor Schneider-electric
Subscribe
Total
757 CVE
| CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
|---|---|---|---|---|---|
| CVE-2023-22610 | 1 Schneider-electric | 3 Ecostruxure Geo Scada Expert 2019, Ecostruxure Geo Scada Expert 2020, Ecostruxure Geo Scada Expert 2021 | 2023-06-14 | N/A | 7.5 HIGH |
| A CWE-863: Incorrect Authorization vulnerability exists that could cause Denial of Service against the Geo SCADA server when specific messages are sent to the server over the database server TCP port. | |||||
| CVE-2022-46680 | 1 Schneider-electric | 10 Powerlogic Ion7400, Powerlogic Ion7400 Firmware, Powerlogic Ion8650 and 7 more | 2023-05-27 | N/A | 9.8 CRITICAL |
| A CWE-319: Cleartext transmission of sensitive information vulnerability exists that could cause disclosure of sensitive information, denial of service, or modification of data if an attacker is able to intercept network traffic. | |||||
| CVE-2023-2161 | 1 Schneider-electric | 1 Opc Factory Server | 2023-05-25 | N/A | 5.5 MEDIUM |
| A CWE-611: Improper Restriction of XML External Entity Reference vulnerability exists that could cause unauthorized read access to the file system when a malicious configuration file is loaded on to the software by a local user. | |||||
| CVE-2023-27979 | 1 Schneider-electric | 3 Custom Reports, Igss Dashboard, Igss Data Server | 2023-05-24 | N/A | 6.5 MEDIUM |
| A CWE-345: Insufficient Verification of Data Authenticity vulnerability exists in the Data Server that could allow the renaming of files in the IGSS project report directory, this could lead to denial of service when an attacker sends specific crafted messages to the Data Server TCP port. Affected Products: IGSS Data Server(IGSSdataServer.exe)(V16.0.0.23040 and prior), IGSS Dashboard(DashBoard.exe)(V16.0.0.23040 and prior), Custom Reports(RMS16.dll)(V16.0.0.23040 and prior). | |||||
| CVE-2022-32528 | 1 Schneider-electric | 1 Interactive Graphical Scada System | 2023-05-16 | N/A | 9.1 CRITICAL |
| A CWE-306: Missing Authentication for Critical Function vulnerability exists that could cause access to manipulate and read specific files in the IGSS project report directory, potentially leading to a denial-of-service condition when an attacker sends specific messages. Affected Products: IGSS Data Server - IGSSdataServer.exe (Versions prior to V15.0.0.22170) | |||||
| CVE-2023-27977 | 1 Schneider-electric | 3 Custom Reports, Igss Dashboard, Igss Data Server | 2023-05-15 | N/A | 5.3 MEDIUM |
| A CWE-345: Insufficient Verification of Data Authenticity vulnerability exists in the Data Server that could cause access to delete files in the IGSS project report directory, this could lead to loss of data when an attacker sends specific crafted messages to the Data Server TCP port. Affected Products: IGSS Data Server(IGSSdataServer.exe)(V16.0.0.23040 and prior), IGSS Dashboard(DashBoard.exe)(V16.0.0.23040 and prior), Custom Reports(RMS16.dll)(V16.0.0.23040 and prior). | |||||
| CVE-2023-1548 | 1 Schneider-electric | 1 Ecostruxure Control Expert | 2023-05-12 | N/A | 5.5 MEDIUM |
| A CWE-269: Improper Privilege Management vulnerability exists that could cause a local user to perform a denial of service through the console server service that is part of EcoStruxure Control Expert. Affected Products: EcoStruxure Control Expert (V15.1 and above) | |||||
| CVE-2023-25620 | 1 Schneider-electric | 16 140cpu65, 140cpu65 Firmware, Bmeh58s and 13 more | 2023-05-12 | N/A | 6.5 MEDIUM |
| A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that could cause denial of service of the controller when a malicious project file is loaded onto the controller by an authenticated user. | |||||
| CVE-2023-27976 | 1 Schneider-electric | 1 Ecostruxure Control Expert | 2023-05-12 | N/A | 8.8 HIGH |
| A CWE-668: Exposure of Resource to Wrong Sphere vulnerability exists that could cause remote code execution when a valid user visits a malicious link provided through the web endpoints. Affected Products: EcoStruxure Control Expert (V15.1 and above) | |||||
| CVE-2023-28003 | 1 Schneider-electric | 1 Ecostruxure Power Monitoring Expert | 2023-05-01 | N/A | 8.8 HIGH |
| A CWE-613: Insufficient Session Expiration vulnerability exists that could allow an attacker to maintain unauthorized access over a hijacked session in PME after the legitimate user has signed out of their account. | |||||
| CVE-2023-25556 | 1 Schneider-electric | 14 Merten Instabus Tastermodul 1fach System M, Merten Instabus Tastermodul 1fach System M Firmware, Merten Instabus Tastermodul 2fach System M and 11 more | 2023-04-28 | N/A | 8.8 HIGH |
| A CWE-287: Improper Authentication vulnerability exists that could allow a device to be compromised when a key of less than seven digits is entered and the attacker has access to the KNX installation. | |||||
| CVE-2023-29411 | 2 Microsoft, Schneider-electric | 7 Windows 10, Windows 11, Windows Server 2016 and 4 more | 2023-04-28 | N/A | 9.8 CRITICAL |
| A CWE-306: Missing Authentication for Critical Function vulnerability exists that could allow changes to administrative credentials, leading to potential remote code execution without requiring prior authentication on the Java RMI interface. | |||||
| CVE-2023-29413 | 2 Microsoft, Schneider-electric | 7 Windows 10, Windows 11, Windows Server 2016 and 4 more | 2023-04-28 | N/A | 7.5 HIGH |
| A CWE-306: Missing Authentication for Critical Function vulnerability exists that could cause Denial-of-Service when accessed by an unauthenticated user on the Schneider UPS Monitor service. | |||||
| CVE-2023-28004 | 1 Schneider-electric | 2 Powerlogic Hdpm6000, Powerlogic Hdpm6000 Firmware | 2023-04-28 | N/A | 9.8 CRITICAL |
| A CWE-129: Improper validation of an array index vulnerability exists where a specially crafted Ethernet request could result in denial of service or remote code execution. | |||||
| CVE-2023-29410 | 1 Schneider-electric | 6 Conext Gateway, Conext Gateway Firmware, Insightfacility and 3 more | 2023-04-28 | N/A | 8.8 HIGH |
| A CWE-20: Improper Input Validation vulnerability exists that could allow an authenticated attacker to gain the same privilege as the application on the server when a malicious payload is provided over HTTP for the server to execute. | |||||
| CVE-2023-25547 | 1 Schneider-electric | 1 Struxureware Data Center Expert | 2023-04-27 | N/A | 8.8 HIGH |
| A CWE-863: Incorrect Authorization vulnerability exists that could allow remote code execution on upload and install packages when a hacker is using a low privileged user account. Affected products: StruxureWare Data Center Expert (V7.9.2 and prior) | |||||
| CVE-2022-43378 | 1 Schneider-electric | 10 Netbotz 355, Netbotz 355 Firmware, Netbotz 450 and 7 more | 2023-04-27 | N/A | 6.5 MEDIUM |
| A CWE-1021: Improper Restriction of Rendered UI Layers or Frames vulnerability exists that could cause the user to be tricked into performing unintended actions when external address frames are not properly restricted. Affected Products: NetBotz 4 - 355/450/455/550/570 (V4.7.0 and prior) | |||||
| CVE-2022-34755 | 1 Schneider-electric | 1 Easergy Builder Installer | 2023-04-27 | N/A | 6.7 MEDIUM |
| A CWE-427 - Uncontrolled Search Path Element vulnerability exists that could allow an attacker with a local privileged account to place a specially crafted file on the target machine, which may give the attacker the ability to execute arbitrary code during the installation process initiated by a valid user. Affected Products: Easergy Builder Installer (1.7.23 and prior) | |||||
| CVE-2023-25548 | 1 Schneider-electric | 1 Struxureware Data Center Expert | 2023-04-27 | N/A | 6.5 MEDIUM |
| A CWE-863: Incorrect Authorization vulnerability exists that could allow access to device credentials on specific DCE endpoints not being properly secured when a hacker is using a low privileged user. Affected products: StruxureWare Data Center Expert (V7.9.2 and prior) | |||||
| CVE-2023-25549 | 1 Schneider-electric | 1 Struxureware Data Center Expert | 2023-04-27 | N/A | 9.8 CRITICAL |
| A CWE-94: Improper Control of Generation of Code ('Code Injection') vulnerability exists that allows for remote code execution when using a parameter of the DCE network settings endpoint. Affected products: StruxureWare Data Center Expert (V7.9.2 and prior) | |||||