Filtered by vendor Siemens
Subscribe
Total
1983 CVE
CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
---|---|---|---|---|---|
CVE-2021-44005 | 1 Siemens | 2 Jt2go, Teamcenter Visualization | 2021-12-15 | 6.8 MEDIUM | 7.8 HIGH |
A vulnerability has been identified in JT2Go (All versions < V13.2.0.5), Teamcenter Visualization (All versions < V13.2.0.5). The Tiff_Loader.dll contains an out of bounds write past the end of an allocated structure while parsing specially crafted TIFF files. This could allow an attacker to execute code in the context of the current process. | |||||
CVE-2021-44006 | 1 Siemens | 2 Jt2go, Teamcenter Visualization | 2021-12-15 | 6.8 MEDIUM | 7.8 HIGH |
A vulnerability has been identified in JT2Go (All versions < V13.2.0.5), Teamcenter Visualization (All versions < V13.2.0.5). The Tiff_Loader.dll contains an out of bounds write past the end of an allocated structure while parsing specially crafted TIFF files. This could allow an attacker to execute code in the context of the current process. | |||||
CVE-2021-44007 | 1 Siemens | 2 Jt2go, Teamcenter Visualization | 2021-12-15 | 4.3 MEDIUM | 5.5 MEDIUM |
A vulnerability has been identified in JT2Go (All versions < V13.2.0.5), Teamcenter Visualization (All versions < V13.2.0.5). The Tiff_Loader.dll contains an off-by-one error in the heap while parsing specially crafted TIFF files. This could allow an attacker to cause a denial-of-service condition. | |||||
CVE-2021-44009 | 1 Siemens | 2 Jt2go, Teamcenter Visualization | 2021-12-15 | 4.3 MEDIUM | 5.5 MEDIUM |
A vulnerability has been identified in JT2Go (All versions < V13.2.0.5), Teamcenter Visualization (All versions < V13.2.0.5). The Tiff_Loader.dll is vulnerable to an out of bounds read past the end of an allocated buffer when parsing TIFF files. An attacker could leverage this vulnerability to leak information in the context of the current process. | |||||
CVE-2021-44008 | 1 Siemens | 2 Jt2go, Teamcenter Visualization | 2021-12-15 | 4.3 MEDIUM | 5.5 MEDIUM |
A vulnerability has been identified in JT2Go (All versions < V13.2.0.5), Teamcenter Visualization (All versions < V13.2.0.5). The Tiff_Loader.dll is vulnerable to an out of bounds read past the end of an allocated buffer when parsing TIFF files. An attacker could leverage this vulnerability to leak information in the context of the current process. | |||||
CVE-2021-44010 | 1 Siemens | 2 Jt2go, Teamcenter Visualization | 2021-12-15 | 4.3 MEDIUM | 5.5 MEDIUM |
A vulnerability has been identified in JT2Go (All versions < V13.2.0.5), Teamcenter Visualization (All versions < V13.2.0.5). The Tiff_Loader.dll is vulnerable to an out of bounds read past the end of an allocated buffer when parsing TIFF files. An attacker could leverage this vulnerability to leak information in the context of the current process. | |||||
CVE-2021-33720 | 1 Siemens | 3 Siprotec 5 With Cpu Variant Cp050, Siprotec 5 With Cpu Variant Cp100, Siprotec 5 With Cpu Variant Cp300 | 2021-12-14 | 5.0 MEDIUM | 7.5 HIGH |
A vulnerability has been identified in SIPROTEC 5 relays with CPU variants CP050 (All versions < V8.80), SIPROTEC 5 relays with CPU variants CP100 (All versions < V8.80), SIPROTEC 5 relays with CPU variants CP300 (All versions < V8.80). Specially crafted packets sent to port 4443/tcp could cause a Denial-of-Service condition. | |||||
CVE-2021-37173 | 1 Siemens | 20 Ruggedcom Rox Mx5000, Ruggedcom Rox Mx5000 Firmware, Ruggedcom Rox Rx1400 and 17 more | 2021-12-14 | 9.0 HIGH | 8.8 HIGH |
A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions < V2.14.1), RUGGEDCOM ROX RX1400 (All versions < V2.14.1), RUGGEDCOM ROX RX1500 (All versions < V2.14.1), RUGGEDCOM ROX RX1501 (All versions < V2.14.1), RUGGEDCOM ROX RX1510 (All versions < V2.14.1), RUGGEDCOM ROX RX1511 (All versions < V2.14.1), RUGGEDCOM ROX RX1512 (All versions < V2.14.1), RUGGEDCOM ROX RX1524 (All versions < V2.14.1), RUGGEDCOM ROX RX1536 (All versions < V2.14.1), RUGGEDCOM ROX RX5000 (All versions < V2.14.1). The command line interface of affected devices insufficiently restrict file read and write operations for low privileged users. This could allow an authenticated remote attacker to escalate privileges and gain root access to the device. | |||||
CVE-2021-37206 | 1 Siemens | 3 Siprotec 5 With Cpu Variant Cp050, Siprotec 5 With Cpu Variant Cp100, Siprotec 5 With Cpu Variant Cp300 | 2021-12-14 | 5.0 MEDIUM | 7.5 HIGH |
A vulnerability has been identified in SIPROTEC 5 relays with CPU variants CP050 (All versions < V8.80), SIPROTEC 5 relays with CPU variants CP100 (All versions < V8.80), SIPROTEC 5 relays with CPU variants CP300 (All versions < V8.80). Received webpackets are not properly processed. An unauthenticated remote attacker with access to any of the Ethernet interfaces could send specially crafted packets to force a restart of the target device. | |||||
CVE-2021-44436 | 1 Siemens | 2 Jt Open Toolkit, Jt Utilities | 2021-12-14 | 4.3 MEDIUM | 3.3 LOW |
A vulnerability has been identified in JT Utilities (All versions < V13.1.1.0), JTTK (All versions < V11.1.1.0). JTTK library in affected products is vulnerable to an out of bounds read past the end of an allocated buffer when parsing specially crafted JT files. An attacker could leverage this vulnerability to leak information in the context of the current process. (ZDI-CAN-14905) | |||||
CVE-2021-44435 | 1 Siemens | 2 Jt Open Toolkit, Jt Utilities | 2021-12-14 | 6.8 MEDIUM | 7.8 HIGH |
A vulnerability has been identified in JT Utilities (All versions < V13.1.1.0), JTTK (All versions < V11.1.1.0). JTTK library in affected products is vulnerable to stack based buffer overflow while parsing specially crafted JT files. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-14903) | |||||
CVE-2021-44430 | 1 Siemens | 2 Jt Open Toolkit, Jt Utilities | 2021-12-14 | 6.8 MEDIUM | 7.8 HIGH |
A vulnerability has been identified in JT Utilities (All versions < V13.1.1.0), JTTK (All versions < V11.1.1.0). JTTK library in affected products is vulnerable to an out of bounds write past the end of an allocated structure while parsing specially crafted JT files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-14829) | |||||
CVE-2021-44433 | 1 Siemens | 2 Jt Open Toolkit, Jt Utilities | 2021-12-14 | 6.8 MEDIUM | 7.8 HIGH |
A vulnerability has been identified in JT Utilities (All versions < V13.1.1.0), JTTK (All versions < V11.1.1.0). JTTK library in affected products contains a use after free vulnerability that could be triggered while parsing specially crafted JT files. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-14900) | |||||
CVE-2021-44448 | 1 Siemens | 2 Jt Open Toolkit, Jt Utilities | 2021-12-14 | 4.3 MEDIUM | 3.3 LOW |
A vulnerability has been identified in JT Utilities (All versions < V13.0.3.0), JTTK (All versions < V11.0.3.0). JTTK library in affected products is vulnerable to an out of bounds read past the end of an allocated buffer when parsing JT files. An attacker could leverage this vulnerability to leak information in the context of the current process. (ZDI-CAN-14843, ZDI-CAN-15051) | |||||
CVE-2021-44449 | 1 Siemens | 2 Jt Open Toolkit, Jt Utilities | 2021-12-14 | 6.8 MEDIUM | 7.8 HIGH |
A vulnerability has been identified in JT Utilities (All versions < V12.8.1.1), JTTK (All versions < V10.8.1.1). JTTK library in affected products contains an out of bounds write past the end of an allocated structure while parsing specially crafted JT files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-14830) | |||||
CVE-2021-44447 | 1 Siemens | 2 Jt Open Toolkit, Jt Utilities | 2021-12-14 | 6.8 MEDIUM | 7.8 HIGH |
A vulnerability has been identified in JT Utilities (All versions < V13.0.3.0), JTTK (All versions < V11.0.3.0). JTTK library in affected products contains a use-after-free vulnerability that could be triggered while parsing specially crafted JT files. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-14911) | |||||
CVE-2021-44439 | 1 Siemens | 2 Jt Open Toolkit, Jt Utilities | 2021-12-14 | 6.8 MEDIUM | 7.8 HIGH |
A vulnerability has been identified in JT Utilities (All versions < V13.1.1.0), JTTK (All versions < V11.1.1.0). JTTK library in affected products is vulnerable to an out of bounds read past the end of an allocated buffer when parsing specially crafted JT files. An attacker could leverage this vulnerability to leak information in the context of the current process. (ZDI-CAN-14908) | |||||
CVE-2021-44438 | 1 Siemens | 2 Jt Open Toolkit, Jt Utilities | 2021-12-14 | 6.8 MEDIUM | 7.8 HIGH |
A vulnerability has been identified in JT Utilities (All versions < V13.1.1.0), JTTK (All versions < V11.1.1.0). JTTK library in affected products is vulnerable to an out of bounds write past the end of an allocated structure while parsing specially crafted JT files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-14907) | |||||
CVE-2021-44437 | 1 Siemens | 2 Jt Open Toolkit, Jt Utilities | 2021-12-14 | 6.8 MEDIUM | 7.8 HIGH |
A vulnerability has been identified in JT Utilities (All versions < V13.1.1.0), JTTK (All versions < V11.1.1.0). JTTK library in affected products is vulnerable to an out of bounds write past the end of an allocated structure while parsing specially crafted JT files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-14906) | |||||
CVE-2021-44442 | 1 Siemens | 2 Jt Open Toolkit, Jt Utilities | 2021-12-14 | 6.8 MEDIUM | 7.8 HIGH |
A vulnerability has been identified in JT Utilities (All versions < V13.1.1.0), JTTK (All versions < V11.1.1.0). JTTK library in affected products contains an out of bounds write past the fixed-length heap-based buffer while parsing specially crafted JT files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-14995) |