Filtered by vendor Deltaww
Subscribe
Total
253 CVE
CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
---|---|---|---|---|---|
CVE-2022-41688 | 1 Deltaww | 1 Infrasuite Device Master | 2023-11-07 | N/A | 7.5 HIGH |
Delta Electronics InfraSuite Device Master versions 00.00.01a and prior lack proper authentication for functions that create and modify user groups. An attacker could provide malicious serialized objects that could run these functions without authentication to create a new user and add them to the administrator group. | |||||
CVE-2022-41772 | 1 Deltaww | 1 Infrasuite Device Master | 2023-11-07 | N/A | 9.8 CRITICAL |
Delta Electronics InfraSuite Device Master Versions 00.00.01a and prior mishandle .ZIP archives containing characters used in path traversal. This path traversal could result in remote code execution. | |||||
CVE-2022-41778 | 1 Deltaww | 1 Infrasuite Device Master | 2023-11-07 | N/A | 8.8 HIGH |
Delta Electronics InfraSuite Device Master versions 00.00.01a and prior deserialize user-supplied data provided through the Device-DataCollect service port without proper verification. An attacker could provide malicious serialized objects to execute arbitrary code upon deserialization. | |||||
CVE-2022-41629 | 1 Deltaww | 1 Infrasuite Device Master | 2023-11-07 | N/A | 9.1 CRITICAL |
Delta Electronics InfraSuite Device Master versions 00.00.01a and prior allow unauthenticated users to access the aprunning endpoint, which could allow an attacker to retrieve any file from the “RunningConfigs” directory. The attacker could then view and modify configuration files such as UserListInfo.xml, which would allow them to see existing administrative passwords. | |||||
CVE-2022-41657 | 1 Deltaww | 1 Infrasuite Device Master | 2023-11-07 | N/A | 9.8 CRITICAL |
Delta Electronics InfraSuite Device Master Versions 00.00.01a and prior allow attacker provided data already serialized into memory to be used in file operation application programmable interfaces (APIs). This could create arbitrary files, which could be used in API operations and could ultimately result in remote code execution. | |||||
CVE-2022-40202 | 1 Deltaww | 1 Infrasuite Device Master | 2023-11-07 | N/A | 9.8 CRITICAL |
The database backup function in Delta Electronics InfraSuite Device Master Versions 00.00.01a and prior lacks proper authentication. An attacker could provide malicious serialized objects which, when deserialized, could activate an opcode for a backup scheduling function without authentication. This function allows the user to designate all function arguments and the file to be executed. This could allow the attacker to start any new process and achieve remote code execution. | |||||
CVE-2022-41644 | 1 Deltaww | 1 Infrasuite Device Master | 2023-11-07 | N/A | 8.8 HIGH |
Delta Electronics InfraSuite Device Master versions 00.00.01a and prior lacks authentication for a function that changes group privileges. An attacker could use this to create a denial-of-service state or escalate their own privileges. | |||||
CVE-2022-38142 | 1 Deltaww | 1 Infrasuite Device Master | 2023-11-07 | N/A | 9.8 CRITICAL |
Delta Electronics InfraSuite Device Master versions 00.00.01a and prior deserialize user-supplied data provided through the Device-Gateway service port without proper verification. An attacker could provide malicious serialized objects to execute arbitrary code upon deserialization. | |||||
CVE-2022-2966 | 1 Deltaww | 1 Dopsoft | 2023-11-07 | N/A | 7.5 HIGH |
Out-of-bounds Read vulnerability in Delta Electronics DOPSoft.This issue affects DOPSoft: All Versions. | |||||
CVE-2022-2660 | 1 Deltaww | 1 Dialink | 2023-11-07 | N/A | 7.5 HIGH |
Delta Industrial Automation DIALink versions 1.4.0.0 and prior are vulnerable to the use of a hard-coded cryptographic key which could allow an attacker to decrypt sensitive data and compromise the machine. | |||||
CVE-2018-14824 | 1 Deltaww | 1 Delta Industrial Automation Pmsoft | 2023-11-07 | 4.3 MEDIUM | 6.5 MEDIUM |
Delta Electronics Delta Industrial Automation PMSoft v2.11 or prior has an out-of-bounds read vulnerability that can be executed when processing project files, which may allow an attacker to read confidential information. | |||||
CVE-2022-41775 | 1 Deltaww | 1 Diaenergie | 2023-10-30 | N/A | 8.8 HIGH |
SQL Injection in Handler_CFG.ashx in Delta Electronics DIAEnergie versions prior to v1.9.02.001 allows an attacker to inject SQL queries via Network | |||||
CVE-2022-43506 | 1 Deltaww | 1 Diaenergie | 2023-10-30 | N/A | 8.8 HIGH |
SQL Injection in HandlerTag_KID.ashx in Delta Electronics DIAEnergie versions prior to v1.9.02.001 allows an attacker to inject SQL queries via Network | |||||
CVE-2022-43447 | 1 Deltaww | 1 Diaenergie | 2023-10-30 | N/A | 8.8 HIGH |
SQL Injection in AM_EBillAnalysis.aspx in Delta Electronics DIAEnergie versions prior to v1.9.02.001 allows an attacker to inject SQL queries via Network | |||||
CVE-2022-43452 | 1 Deltaww | 1 Diaenergie | 2023-10-27 | N/A | 8.8 HIGH |
SQL Injection in FtyInfoSetting.aspx in Delta Electronics DIAEnergie versions prior to v1.9.02.001 allows an attacker to inject SQL queries via Network | |||||
CVE-2023-25177 | 1 Deltaww | 1 Cncsoft-b | 2023-06-14 | N/A | 7.8 HIGH |
Delta Electronics' CNCSoft-B DOPSoft versions 1.0.0.4 and prior are vulnerable to stack-based buffer overflow, which could allow an attacker to execute arbitrary code. | |||||
CVE-2023-24014 | 1 Deltaww | 1 Cncsoft-b | 2023-06-14 | N/A | 7.8 HIGH |
Delta Electronics' CNCSoft-B DOPSoft versions 1.0.0.4 and prior are vulnerable to heap-based buffer overflow, which could allow an attacker to execute arbitrary code. | |||||
CVE-2019-13513 | 1 Deltaww | 1 Delta Industrial Automation Dopsoft | 2023-03-03 | 6.8 MEDIUM | 7.8 HIGH |
In Delta Industrial Automation DOPSoft, Version 4.00.06.15 and prior, processing a specially crafted project file may trigger multiple out-of-bounds read vulnerabilities, which may allow information disclosure, remote code execution, or crash of the application. | |||||
CVE-2019-13514 | 1 Deltaww | 1 Delta Industrial Automation Dopsoft | 2023-03-03 | 6.8 MEDIUM | 7.8 HIGH |
In Delta Industrial Automation DOPSoft, Version 4.00.06.15 and prior, processing a specially crafted project file may trigger a use-after-free vulnerability, which may allow information disclosure, remote code execution, or crash of the application. | |||||
CVE-2022-2969 | 1 Deltaww | 1 Dialink | 2022-12-07 | N/A | 7.5 HIGH |
Delta Industrial Automation DIALink versions prior to v1.5.0.0 Beta 4 uses an external input to construct a pathname intended to identify a file or directory located underneath a restricted parent directory. However, the software does not properly neutralize special elements within the pathname, which can cause the pathname to resolve to a location outside of the restricted directory. |