Filtered by vendor Siemens
Subscribe
Total
1983 CVE
CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
---|---|---|---|---|---|
CVE-2020-26145 | 2 Samsung, Siemens | 26 Galaxy I9305, Galaxy I9305 Firmware, 6gk5763-1al00-3aa0 and 23 more | 2022-05-13 | 3.3 LOW | 6.5 MEDIUM |
An issue was discovered on Samsung Galaxy S3 i9305 4.4.4 devices. The WEP, WPA, WPA2, and WPA3 implementations accept second (or subsequent) broadcast fragments even when sent in plaintext and process them as full unfragmented frames. An adversary can abuse this to inject arbitrary network packets independent of the network configuration. | |||||
CVE-2021-25669 | 1 Siemens | 58 Scalance X200-4p Irt, Scalance X200-4p Irt Firmware, Scalance X201-3p Irt and 55 more | 2022-05-13 | 7.5 HIGH | 9.8 CRITICAL |
A vulnerability has been identified in SCALANCE X200-4P IRT (All versions < 5.5.1), SCALANCE X201-3P IRT (All versions < 5.5.1), SCALANCE X201-3P IRT PRO (All versions < 5.5.1), SCALANCE X202-2 IRT (All versions < 5.5.1), SCALANCE X202-2P IRT (incl. SIPLUS NET variant) (All versions < 5.5.1), SCALANCE X202-2P IRT PRO (All versions < 5.5.1), SCALANCE X204 IRT (All versions < 5.5.1), SCALANCE X204 IRT PRO (All versions < 5.5.1), SCALANCE X204-2 (incl. SIPLUS NET variant) (All versions < V5.2.5), SCALANCE X204-2FM (All versions < V5.2.5), SCALANCE X204-2LD (incl. SIPLUS NET variant) (All versions < V5.2.5), SCALANCE X204-2LD TS (All versions < V5.2.5), SCALANCE X204-2TS (All versions < V5.2.5), SCALANCE X206-1 (All versions < V5.2.5), SCALANCE X206-1LD (All versions < V5.2.5), SCALANCE X208 (incl. SIPLUS NET variant) (All versions < V5.2.5), SCALANCE X208PRO (All versions < V5.2.5), SCALANCE X212-2 (incl. SIPLUS NET variant) (All versions < V5.2.5), SCALANCE X212-2LD (All versions < V5.2.5), SCALANCE X216 (All versions < V5.2.5), SCALANCE X224 (All versions < V5.2.5), SCALANCE XF201-3P IRT (All versions < 5.5.1), SCALANCE XF202-2P IRT (All versions < 5.5.1), SCALANCE XF204 (All versions < V5.2.5), SCALANCE XF204 IRT (All versions < 5.5.1), SCALANCE XF204-2 (incl. SIPLUS NET variant) (All versions < V5.2.5), SCALANCE XF204-2BA IRT (All versions < 5.5.1), SCALANCE XF206-1 (All versions < V5.2.5), SCALANCE XF208 (All versions < V5.2.5). Incorrect processing of POST requests in the web server may write out of bounds in stack. An attacker might leverage this to denial-of-service of the device or remote code execution. | |||||
CVE-2021-27290 | 3 Oracle, Siemens, Ssri Project | 3 Graalvm, Sinec Infrastructure Network Services, Ssri | 2022-05-13 | 4.3 MEDIUM | 7.5 HIGH |
ssri 5.2.2-8.0.0, fixed in 8.0.1, processes SRIs using a regular expression which is vulnerable to a denial of service. Malicious SRIs could take an extremely long time to process, leading to denial of service. This issue only affects consumers using the strict option. | |||||
CVE-2021-32952 | 2 Opendesign, Siemens | 4 Drawings Sdk, Comos, Jt2go and 1 more | 2022-05-13 | 6.8 MEDIUM | 7.8 HIGH |
An out-of-bounds write issue exists in the DGN file-reading procedure in the Drawings SDK (Version 2022.4 and prior) resulting from the lack of proper validation of user-supplied data. This can result in a write past the end of an allocated buffer and allow attackers to cause a denial-of-service condition or execute code in the context of the current process. | |||||
CVE-2021-20094 | 2 Siemens, Wibu | 4 Pss Cape, Sicam 230, Sicam 230 Firmware and 1 more | 2022-05-13 | 5.0 MEDIUM | 7.5 HIGH |
A denial of service vulnerability exists in Wibu-Systems CodeMeter versions < 7.21a. An unauthenticated remote attacker can exploit this issue to crash the CodeMeter Runtime Server. | |||||
CVE-2021-37194 | 1 Siemens | 1 Comos | 2022-05-13 | 5.0 MEDIUM | 7.5 HIGH |
A vulnerability has been identified in COMOS V10.2 (All versions only if web components are used), COMOS V10.3 (All versions < V10.3.3.3 only if web components are used), COMOS V10.4 (All versions < V10.4.1 only if web components are used). The COMOS Web component of COMOS allows to upload and store arbitrary files at the webserver. This could allow an attacker to store malicious files. | |||||
CVE-2020-24636 | 2 Arubanetworks, Siemens | 3 Instant, Scalance W1750d, Scalance W1750d Firmware | 2022-05-12 | 10.0 HIGH | 9.8 CRITICAL |
A remote execution of arbitrary commands vulnerability was discovered in some Aruba Instant Access Point (IAP) products in version(s): Aruba Instant 6.5.x: 6.5.4.17 and below; Aruba Instant 8.3.x: 8.3.0.13 and below; Aruba Instant 8.5.x: 8.5.0.10 and below; Aruba Instant 8.6.x: 8.6.0.5 and below; Aruba Instant 8.7.x: 8.7.0.0 and below. Aruba has released patches for Aruba Instant that address this security vulnerability. | |||||
CVE-2020-24635 | 2 Arubanetworks, Siemens | 3 Instant, Scalance W1750d, Scalance W1750d Firmware | 2022-05-12 | 9.0 HIGH | 7.2 HIGH |
A remote execution of arbitrary commands vulnerability was discovered in some Aruba Instant Access Point (IAP) products in version(s): Aruba Instant 6.5.x: 6.5.4.17 and below; Aruba Instant 8.3.x: 8.3.0.13 and below; Aruba Instant 8.5.x: 8.5.0.10 and below; Aruba Instant 8.6.x: 8.6.0.5 and below; Aruba Instant 8.7.x: 8.7.0.0 and below. Aruba has released patches for Aruba Instant that address this security vulnerability. | |||||
CVE-2020-15358 | 5 Apple, Canonical, Oracle and 2 more | 16 Icloud, Ipados, Iphone Os and 13 more | 2022-05-12 | 2.1 LOW | 5.5 MEDIUM |
In SQLite before 3.32.3, select.c mishandles query-flattener optimization, leading to a multiSelectOrderBy heap overflow because of misuse of transitive properties for constant propagation. | |||||
CVE-2021-25216 | 4 Debian, Isc, Netapp and 1 more | 23 Debian Linux, Bind, Active Iq Unified Manager and 20 more | 2022-05-03 | 6.8 MEDIUM | 9.8 CRITICAL |
In BIND 9.5.0 -> 9.11.29, 9.12.0 -> 9.16.13, and versions BIND 9.11.3-S1 -> 9.11.29-S1 and 9.16.8-S1 -> 9.16.13-S1 of BIND Supported Preview Edition, as well as release versions 9.17.0 -> 9.17.1 of the BIND 9.17 development branch, BIND servers are vulnerable if they are running an affected version and are configured to use GSS-TSIG features. In a configuration which uses BIND's default settings the vulnerable code path is not exposed, but a server can be rendered vulnerable by explicitly setting values for the tkey-gssapi-keytab or tkey-gssapi-credential configuration options. Although the default configuration is not vulnerable, GSS-TSIG is frequently used in networks where BIND is integrated with Samba, as well as in mixed-server environments that combine BIND servers with Active Directory domain controllers. For servers that meet these conditions, the ISC SPNEGO implementation is vulnerable to various attacks, depending on the CPU architecture for which BIND was built: For named binaries compiled for 64-bit platforms, this flaw can be used to trigger a buffer over-read, leading to a server crash. For named binaries compiled for 32-bit platforms, this flaw can be used to trigger a server crash due to a buffer overflow and possibly also to achieve remote code execution. We have determined that standard SPNEGO implementations are available in the MIT and Heimdal Kerberos libraries, which support a broad range of operating systems, rendering the ISC implementation unnecessary and obsolete. Therefore, to reduce the attack surface for BIND users, we will be removing the ISC SPNEGO implementation in the April releases of BIND 9.11 and 9.16 (it had already been dropped from BIND 9.17). We would not normally remove something from a stable ESV (Extended Support Version) of BIND, but since system libraries can replace the ISC SPNEGO implementation, we have made an exception in this case for reasons of stability and security. | |||||
CVE-2021-25668 | 1 Siemens | 58 Scalance X200-4p Irt, Scalance X200-4p Irt Firmware, Scalance X201-3p Irt and 55 more | 2022-05-01 | 7.5 HIGH | 9.8 CRITICAL |
A vulnerability has been identified in SCALANCE X200-4P IRT (All versions < 5.5.1), SCALANCE X201-3P IRT (All versions < 5.5.1), SCALANCE X201-3P IRT PRO (All versions < 5.5.1), SCALANCE X202-2 IRT (All versions < 5.5.1), SCALANCE X202-2P IRT (incl. SIPLUS NET variant) (All versions < 5.5.1), SCALANCE X202-2P IRT PRO (All versions < 5.5.1), SCALANCE X204 IRT (All versions < 5.5.1), SCALANCE X204 IRT PRO (All versions < 5.5.1), SCALANCE X204-2 (incl. SIPLUS NET variant) (All versions < V5.2.5), SCALANCE X204-2FM (All versions < V5.2.5), SCALANCE X204-2LD (incl. SIPLUS NET variant) (All versions < V5.2.5), SCALANCE X204-2LD TS (All versions < V5.2.5), SCALANCE X204-2TS (All versions < V5.2.5), SCALANCE X206-1 (All versions < V5.2.5), SCALANCE X206-1LD (All versions < V5.2.5), SCALANCE X208 (incl. SIPLUS NET variant) (All versions < V5.2.5), SCALANCE X208PRO (All versions < V5.2.5), SCALANCE X212-2 (incl. SIPLUS NET variant) (All versions < V5.2.5), SCALANCE X212-2LD (All versions < V5.2.5), SCALANCE X216 (All versions < V5.2.5), SCALANCE X224 (All versions < V5.2.5), SCALANCE XF201-3P IRT (All versions < 5.5.1), SCALANCE XF202-2P IRT (All versions < 5.5.1), SCALANCE XF204 (All versions < V5.2.5), SCALANCE XF204 IRT (All versions < 5.5.1), SCALANCE XF204-2 (incl. SIPLUS NET variant) (All versions < V5.2.5), SCALANCE XF204-2BA IRT (All versions < 5.5.1), SCALANCE XF206-1 (All versions < V5.2.5), SCALANCE XF208 (All versions < V5.2.5). Incorrect processing of POST requests in the webserver may result in write out of bounds in heap. An attacker might leverage this to cause denial-of-service on the device and potentially remotely execute code. | |||||
CVE-2021-37196 | 1 Siemens | 1 Comos | 2022-04-30 | 3.5 LOW | 6.5 MEDIUM |
A vulnerability has been identified in COMOS V10.2 (All versions only if web components are used), COMOS V10.3 (All versions < V10.3.3.3 only if web components are used), COMOS V10.3 (All versions >= V10.3.3.3 only if web components are used), COMOS V10.4 (All versions < V10.4.1 only if web components are used). The COMOS Web component of COMOS unpacks specially crafted archive files to relative paths. This vulnerability could allow an attacker to store files in any folder accessible by the COMOS Web webservice. | |||||
CVE-2021-37197 | 1 Siemens | 1 Comos | 2022-04-30 | 6.0 MEDIUM | 8.8 HIGH |
A vulnerability has been identified in COMOS V10.2 (All versions only if web components are used), COMOS V10.3 (All versions < V10.3.3.3 only if web components are used), COMOS V10.4 (All versions < V10.4.1 only if web components are used). The COMOS Web component of COMOS is vulnerable to SQL injections. This could allow an attacker to execute arbitrary SQL statements. | |||||
CVE-2020-27001 | 1 Siemens | 2 Jt2go, Teamcenter Visualization | 2022-04-29 | 4.6 MEDIUM | 7.8 HIGH |
A vulnerability has been identified in JT2Go (All versions < V13.1.0.2), Teamcenter Visualization (All versions < V13.1.0.2). Affected applications lack proper validation of user-supplied data when parsing of PAR files. This could result in a stack based buffer overflow. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-12041) | |||||
CVE-2020-28392 | 1 Siemens | 1 Simaris Configuration | 2022-04-29 | 4.6 MEDIUM | 7.8 HIGH |
A vulnerability has been identified in SIMARIS configuration (All versions < V4.0.1). During installation to default target folder, incorrect permissions are configured for the application folder and subfolders which could allow an attacker to gain persistence or potentially escalate privileges should a user with elevated credentials log onto the machine. | |||||
CVE-2020-27002 | 1 Siemens | 2 Jt2go, Teamcenter Visualization | 2022-04-29 | 3.6 LOW | 7.1 HIGH |
A vulnerability has been identified in JT2Go (All versions < V13.1.0.2), Teamcenter Visualization (All versions < V13.1.0.2). Affected applications lack proper validation of user-supplied data when parsing of PAR files. This could result in a memory access past the end of an allocated buffer. An attacker could leverage this vulnerability to access data in the context of the current process. (ZDI-CAN-12043) | |||||
CVE-2021-37195 | 1 Siemens | 1 Comos | 2022-04-29 | 2.6 LOW | 6.1 MEDIUM |
A vulnerability has been identified in COMOS V10.2 (All versions only if web components are used), COMOS V10.3 (All versions < V10.3.3.3 only if web components are used), COMOS V10.4 (All versions < V10.4.1 only if web components are used). The COMOS Web component of COMOS accepts arbitrary code as attachment to tasks. This could allow an attacker to inject malicious code that is executed when loading the attachment. | |||||
CVE-2021-37186 | 1 Siemens | 12 Logo\! Cmr2020, Logo\! Cmr2020 Firmware, Logo\! Cmr2040 and 9 more | 2022-04-29 | 4.8 MEDIUM | 5.4 MEDIUM |
A vulnerability has been identified in LOGO! CMR2020 (All versions < V2.2), LOGO! CMR2040 (All versions < V2.2), SIMATIC RTU3010C (All versions < V4.0.9), SIMATIC RTU3030C (All versions < V4.0.9), SIMATIC RTU3031C (All versions < V4.0.9), SIMATIC RTU3041C (All versions < V4.0.9). The underlying TCP/IP stack does not properly calculate the random numbers used as ISN (Initial Sequence Numbers). An adjacent attacker with network access to the LAN interface could interfere with traffic, spoof the connection and gain access to sensitive information. | |||||
CVE-2020-0591 | 2 Intel, Siemens | 202 Bios, Core I5-7640x, Core I7-3820 and 199 more | 2022-04-26 | 4.6 MEDIUM | 6.7 MEDIUM |
Improper buffer restrictions in BIOS firmware for some Intel(R) Processors may allow a privileged user to potentially enable escalation of privilege via local access. | |||||
CVE-2021-27397 | 1 Siemens | 1 Tecnomatix Plant Simulation | 2022-04-25 | 6.8 MEDIUM | 7.8 HIGH |
A vulnerability has been identified in Tecnomatix Plant Simulation (All versions < V16.0.5). The PlantSimCore.dll library lacks proper validation of user-supplied data when parsing SPP files. This could result in a memory corruption condition. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-13287) |