CVE-2024-36604 | 1 Tenda | 2 O3, O3 Firmware | 2024-12-13 | N/A | 9.8 CRITICAL |
Tenda O3V2 v1.0.0.12(3880) was discovered to contain a Blind Command Injection via stpEn parameter in the SetStp function. This vulnerability allows attackers to execute arbitrary commands with root privileges. | |||||
CVE-2024-44390 | 1 Tenda | 2 Fh1206, Fh1206 Firmware | 2024-12-13 | N/A | 8.8 HIGH |
Tenda FH1206 V1.2.0.8(8155)_EN contains a Buffer Overflow vulnerability via the function formWrlsafeset. | |||||
CVE-2024-44387 | 1 Tenda | 2 Fh1206, Fh1206 Firmware | 2024-12-13 | N/A | 6.5 MEDIUM |
Tenda FH1206 V1.2.0.8(8155)_EN contains a Buffer Overflow vulnerability via the functino formWrlExtraGet. | |||||
CVE-2024-2764 | 1 Tenda | 2 Ac10u, Ac10u Firmware | 2024-12-12 | N/A | 8.8 HIGH |
A vulnerability, which was classified as critical, was found in Tenda AC10U 15.03.06.48. This affects the function formSetPPTPServer of the file /goform/SetPptpServerCfg. The manipulation of the argument endIP leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257601 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | |||||
CVE-2024-2763 | 1 Tenda | 2 Ac10u, Ac10u Firmware | 2024-12-12 | N/A | 8.8 HIGH |
A vulnerability, which was classified as critical, has been found in Tenda AC10U 15.03.06.48. Affected by this issue is the function formSetCfm of the file goform/setcfm. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257600. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | |||||
CVE-2024-2711 | 1 Tenda | 2 Ac10u, Ac10u Firmware | 2024-12-12 | N/A | 8.8 HIGH |
A vulnerability was found in Tenda AC10U 15.03.06.48. It has been rated as critical. Affected by this issue is the function addWifiMacFilter of the file /goform/addWifiMacFilter. The manipulation of the argument deviceMac leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-257462 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | |||||
CVE-2024-2710 | 1 Tenda | 2 Ac10u, Ac10u Firmware | 2024-12-12 | N/A | 8.8 HIGH |
A vulnerability was found in Tenda AC10U 15.03.06.49. It has been declared as critical. Affected by this vulnerability is the function setSchedWifi of the file /goform/openSchedWifi. The manipulation of the argument schedStartTime leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257461 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | |||||
CVE-2024-2709 | 1 Tenda | 2 Ac10u, Ac10u Firmware | 2024-12-12 | N/A | 8.8 HIGH |
A vulnerability was found in Tenda AC10U 15.03.06.49. It has been classified as critical. Affected is the function fromSetRouteStatic of the file /goform/SetStaticRouteCfg. The manipulation of the argument list leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257460. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | |||||
CVE-2024-2708 | 1 Tenda | 2 Ac10u, Ac10u Firmware | 2024-12-12 | N/A | 8.8 HIGH |
A vulnerability was found in Tenda AC10U 15.03.06.49 and classified as critical. This issue affects the function formexeCommand of the file /goform/execCommand. The manipulation of the argument cmdinput leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-257459. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | |||||
CVE-2024-2707 | 1 Tenda | 2 Ac10u, Ac10u Firmware | 2024-12-12 | N/A | 8.8 HIGH |
A vulnerability has been found in Tenda AC10U 15.03.06.49 and classified as critical. This vulnerability affects the function formWriteFacMac of the file /goform/WriteFacMac. The manipulation of the argument mac leads to os command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-257458 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | |||||
CVE-2024-2706 | 1 Tenda | 2 Ac10u, Ac10u Firmware | 2024-12-12 | N/A | 8.8 HIGH |
A vulnerability, which was classified as critical, was found in Tenda AC10U 15.03.06.49. This affects the function formWifiWpsStart of the file /goform/WifiWpsStart. The manipulation of the argument index leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257457 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | |||||
CVE-2024-2704 | 1 Tenda | 2 Ac10u, Ac10u Firmware | 2024-12-12 | N/A | 8.8 HIGH |
A vulnerability classified as critical was found in Tenda AC10U 15.03.06.49. Affected by this vulnerability is the function formSetFirewallCfg of the file /goform/SetFirewallCfg. The manipulation of the argument firewallEn leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-257455. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | |||||
CVE-2024-2705 | 1 Tenda | 2 Ac10u, Ac10u Firmware | 2024-12-12 | N/A | 8.8 HIGH |
A vulnerability, which was classified as critical, has been found in Tenda AC10U 1.0/15.03.06.49. Affected by this issue is the function formSetQosBand of the file /goform/SetNetControlList. The manipulation of the argument list leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257456. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | |||||
CVE-2024-2703 | 1 Tenda | 2 Ac10u, Ac10u Firmware | 2024-12-12 | N/A | 8.8 HIGH |
A vulnerability classified as critical has been found in Tenda AC10U 15.03.06.49. Affected is the function formSetDeviceName of the file /goform/SetOnlineDevName. The manipulation of the argument mac leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-257454 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | |||||
CVE-2024-12002 | 1 Tenda | 8 Fh1201, Fh1201 Firmware, Fh1202 and 5 more | 2024-12-10 | N/A | 6.5 MEDIUM |
A vulnerability classified as problematic was found in Tenda FH451, FH1201, FH1202 and FH1206 up to 20241129. Affected by this vulnerability is the function websReadEvent of the file /goform/GetIPTV. The manipulation of the argument Content-Length leads to null pointer dereference. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. | |||||
CVE-2024-11745 | 1 Tenda | 2 Ac8, Ac8 Firmware | 2024-12-03 | N/A | 9.8 CRITICAL |
A vulnerability was found in Tenda AC8 16.03.34.09 and classified as critical. Affected by this issue is the function route_static_check of the file /goform/SetStaticRouteCfg. The manipulation of the argument list leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. | |||||
CVE-2024-4164 | 1 Tenda | 2 G3, G3 Firmware | 2024-11-21 | N/A | 9.8 CRITICAL |
A vulnerability, which was classified as critical, has been found in Tenda G3 15.11.0.17(9502). This issue affects the function formModifyPppAuthWhiteMac of the file /goform/ModifyPppAuthWhiteMac. The manipulation of the argument pppoeServerWhiteMacIndex leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-261983. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | |||||
CVE-2024-4165 | 1 Tenda | 2 G3, G3 Firmware | 2024-11-21 | N/A | 9.8 CRITICAL |
A vulnerability, which was classified as critical, was found in Tenda G3 15.11.0.17(9502). Affected is the function modifyDhcpRule of the file /goform/modifyDhcpRule. The manipulation of the argument bindDhcpIndex leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-261984. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | |||||
CVE-2024-52714 | 1 Tenda | 2 Ac6, Ac6 Firmware | 2024-11-20 | N/A | 9.8 CRITICAL |
Tenda AC6 v2.0 v15.03.06.50 was discovered to contain a buffer overflow in the function 'fromSetSysTime. | |||||
CVE-2024-11248 | 1 Tenda | 2 Ac10, Ac10 Firmware | 2024-11-19 | N/A | 8.8 HIGH |
A vulnerability was found in Tenda AC10 16.03.10.13 and classified as critical. Affected by this issue is the function formSetRebootTimer of the file /goform/SetSysAutoRebbotCfg. The manipulation of the argument rebootTime leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. |