CVE Vendors Products Updated CVSS v2 CVSS v3
CVE-2021-0288 1 Juniper 26 Ex9200, Ex9204, Ex9208 and 23 more 2021-07-29 3.3 LOW 6.5 MEDIUM
A vulnerability in the processing of specific MPLS packets in Juniper Networks Junos OS on MX Series and EX9200 Series devices with Trio-based MPCs (Modular Port Concentrators) may cause FPC to crash and lead to a Denial of Service (DoS) condition. Continued receipt of this packet will sustain the Denial of Service (DoS) condition. This issue only affects MX Series and EX9200 Series with Trio-based PFEs (Packet Forwarding Engines). This issue affects Juniper Networks Junos OS on MX Series, EX9200 Series: 17.3 versions prior to 17.3R3-S12; 17.4 versions prior to 17.4R2-S13, 17.4R3-S5; 18.1 versions prior to 18.1R3-S13; 18.2 versions prior to 18.2R3-S8; 18.3 versions prior to 18.3R3-S5; 18.4 versions prior to 18.4R2-S8, 18.4R3-S8; 19.1 versions prior to 19.1R3-S5; 19.2 versions prior to 19.2R3-S2; 19.3 versions prior to 19.3R2-S6, 19.3R3-S3; 19.4 versions prior to 19.4R1-S4, 19.4R2-S4, 19.4R3-S2; 20.1 versions prior to 20.1R3; 20.2 versions prior to 20.2R2-S2, 20.2R3; 20.3 versions prior to 20.3R2; 20.4 versions prior to 20.4R2;
CVE-2021-0289 1 Juniper 229 Acx1000, Acx1100, Acx2000 and 226 more 2021-07-28 2.9 LOW 5.3 MEDIUM
When user-defined ARP Policer is configured and applied on one or more Aggregated Ethernet (AE) interface units, a Time-of-check Time-of-use (TOCTOU) Race Condition vulnerability between the Device Control Daemon (DCD) and firewall process (dfwd) daemons of Juniper Networks Junos OS allows an attacker to bypass the user-defined ARP Policer. In this particular case the User ARP policer is replaced with default ARP policer. To review the desired ARP Policers and actual state one can run the command "show interfaces <> extensive" and review the output. See further details below. An example output is: show interfaces extensive | match policer Policer: Input: __default_arp_policer__ <<< incorrect if user ARP Policer was applied on an AE interface and the default ARP Policer is displayed Policer: Input: jtac-arp-ae5.317-inet-arp <<< correct if user ARP Policer was applied on an AE interface For all platforms, except SRX Series: This issue affects Juniper Networks Junos OS: All versions 5.6R1 and all later versions prior to 18.4 versions prior to 18.4R2-S9, 18.4R3-S9 with the exception of 15.1 versions 15.1R7-S10 and later versions; 19.4 versions prior to 19.4R3-S3; 20.1 versions prior to 20.1R3; 20.2 versions prior to 20.2R3-S2; 20.3 version 20.3R1 and later versions; 20.4 versions prior to 20.4R3; 21.1 versions prior to 21.1R2; This issue does not affect Juniper Networks Junos OS versions prior to 5.6R1. On SRX Series this issue affects Juniper Networks Junos OS: 18.4 versions prior to 18.4R2-S9, 18.4R3-S9; 19.4 versions prior to 19.4R3-S4; 20.1 versions prior to 20.1R3; 20.2 versions prior to 20.2R3-S2; 20.3 version 20.3R1 and later versions; 20.4 versions prior to 20.4R3; 21.1 versions prior to 21.1R2. This issue does not affect 18.4 versions prior to 18.4R1 on SRX Series. This issue does not affect Junos OS Evolved.
CVE-2019-0063 1 Juniper 18 Junos, Mx10, Mx10003 and 15 more 2021-07-21 4.3 MEDIUM 7.5 HIGH
When an MX Series Broadband Remote Access Server (BRAS) is configured as a Broadband Network Gateway (BNG) with DHCPv6 enabled, jdhcpd might crash when receiving a specific crafted DHCP response message on a subscriber interface. The daemon automatically restarts without intervention, but continuous receipt of specific crafted DHCP messages will repeatedly crash jdhcpd, leading to an extended Denial of Service (DoS) condition. This issue only affects systems configured with DHCPv6 enabled. DHCPv4 is unaffected by this issue. This issue affects Juniper Networks Junos OS: 15.1 versions prior to 15.1R7-S5 on MX Series; 16.1 versions prior to 16.1R7-S5 on MX Series; 16.2 versions prior to 16.2R2-S10 on MX Series; 17.1 versions prior to 17.1R3-S1 on MX Series; 17.2 versions prior to 17.2R3-S2 on MX Series; 17.3 versions prior to 17.3R3-S6 on MX Series; 17.4 versions prior to 17.4R2-S5, 17.4R3 on MX Series; 18.1 versions prior to 18.1R3-S6 on MX Series; 18.2 versions prior to 18.2R2-S4, 18.2R3 on MX Series; 18.2X75 versions prior to 18.2X75-D50 on MX Series; 18.3 versions prior to 18.3R1-S5, 18.3R3 on MX Series; 18.4 versions prior to 18.4R2 on MX Series; 19.1 versions prior to 19.1R1-S2, 19.1R2 on MX Series.
CVE-2020-1608 1 Juniper 17 Junos, Mx10, Mx10003 and 14 more 2021-07-21 7.8 HIGH 7.5 HIGH
Receipt of a specific MPLS or IPv6 packet on the core facing interface of an MX Series device configured for Broadband Edge (BBE) service may trigger a kernel crash (vmcore), causing the device to reboot. The issue is specific to the processing of packets destined to BBE clients connected to MX Series subscriber management platforms. This issue affects MX Series running Juniper Networks Junos OS: 17.2 versions starting from17.2R2-S6, 17.2R3 and later releases, prior to 17.2R3-S3; 17.3 versions starting from 17.3R2-S4, 17.3R3-S2 and later releases, prior to 17.3R2-S5, 17.3R3-S5; 17.4 versions starting from 17.4R2 and later releases, prior to 17.4R2-S7,17.4R3; 18.1 versions starting from 18.1R2-S3, 18.1R3 and later releases, prior to 18.1R3-S6; 18.2 versions starting from18.2R1-S1, 18.2R2 and later releases, prior to 18.2R3-S2; 18.2X75 versions prior to 18.2X75-D51, 18.2X75-D60; 18.3 versions prior to 18.3R3; 18.4 versions prior to 18.4R2; 19.1 versions prior to 19.1R1-S3, 19.1R2; 19.2 versions prior to 19.2R1-S2, 19.2R2. This issue does not affect Juniper Networks Junos OS versions prior to 17.2R2-S6.
CVE-2019-0065 1 Juniper 18 Junos, Mx10, Mx10003 and 15 more 2021-07-21 4.3 MEDIUM 7.5 HIGH
On MX Series, when the SIP ALG is enabled, receipt of a certain malformed SIP packet may crash the MS-PIC component on MS-MIC or MS-MPC. By continuously sending a crafted SIP packet, an attacker can repeatedly bring down MS-PIC on MS-MIC/MS-MPC causing a sustained Denial of Service. This issue affects Juniper Networks Junos OS on MX Series: 16.1 versions prior to 16.1R7-S5; 16.2 versions prior to 16.2R2-S11; 17.1 versions prior to 17.1R3; 17.2 versions prior to 17.2R3-S3; 17.3 versions prior to 17.3R3-S6 ; 17.4 versions prior to 17.4R2-S8, 17.4R3; 18.1 versions prior to 18.1R3-S3; 18.2 versions prior to 18.2R3; 18.3 versions prior to 18.3R2; 18.4 versions prior to 18.4R2.
CVE-2021-0273 1 Juniper 9 Acx5800, Ex9200, Junos and 6 more 2021-05-04 5.0 MEDIUM 5.3 MEDIUM
An always-incorrect control flow implementation in the implicit filter terms of Juniper Networks Junos OS and Junos OS Evolved on ACX5800, EX9200 Series, MX10000 Series, MX240, MX480, MX960 devices with affected Trio line cards allows an attacker to exploit an interdependency in the PFE UCODE microcode of the Trio chipset with various line cards to cause packets destined to the devices interfaces to cause a Denial of Service (DoS) condition by looping the packet with an unreachable exit condition ('Infinite Loop'). To break this loop once it begins one side of the affected LT interfaces will need to be disabled. Once disabled, the condition will clear and the disabled LT interface can be reenabled. Continued receipt and processing of these packets will create a sustained Denial of Service (DoS) condition. This issue only affects LT-LT interfaces. Any other interfaces are not affected by this issue. This issue affects the following cards: MPCE Type 3 3D MPC4E 3D 32XGE MPC4E 3D 2CGE+8XGE EX9200 32x10G SFP EX9200-2C-8XS FPC Type 5-3D FPC Type 5-LSR EX9200 4x40G QSFP An Indicator of Compromise (IoC) can be seen by examining the traffic of the LT-LT interfaces for excessive traffic using the following command: monitor interface traffic Before loop impact: Interface: lt-2/0/0, Enabled, Link is Up Encapsulation: Logical-tunnel, Speed: 100000mbps Traffic statistics: Current delta Input bytes: 3759900268942 (1456 bps) [0] <---------- LT interface utilization is low Output bytes: 3759900344309 (1456 bps) [0] <---------- LT interface utilization is low After loop impact: Interface: lt-2/0/0, Enabled, Link is Up Encapsulation: Logical-tunnel, Speed: 100000mbps Traffic statistics: Current delta Input bytes: 3765160313129 (2158268368 bps) [5260044187] <---------- LT interface utilization is very high Output bytes: 3765160399522 (2158266440 bps) [5260055213] <---------- LT interface utilization is very high This issue affects: Juniper Networks Junos OS on ACX5800, EX9200 Series, MX10000 Series, MX240, MX480, MX960. Versions 15.1F6, 16.1R1, and later versions prior to 16.1R7-S8; 17.1 versions prior to 17.1R2-S12; 17.2 versions prior to 17.2R3-S4; 17.3 versions prior to 17.3R3-S8; 17.4 versions prior to 17.4R2-S10, 17.4R3-S2; 18.1 versions prior to 18.1R3-S10; 18.2 versions prior to 18.2R2-S7, 18.2R3-S3; 18.3 versions prior to 18.3R1-S7, 18.3R3-S2; 18.4 versions prior to 18.4R1-S7, 18.4R2-S4, 18.4R3-S2; 19.1 versions prior to 19.1R1-S5, 19.1R2-S1, 19.1R3; 19.2 versions prior to 19.2R1-S4, 19.2R2; 19.3 versions prior to 19.3R2-S3, 19.3R3; 19.4 versions prior to 19.4R1-S1, 19.4R2. This issue does not affect the MX10001. This issue does not affect Juniper Networks Junos OS versions prior to 15.1F6, 16.1R1. Juniper Networks Junos OS Evolved on ACX5800, EX9200 Series, MX10000 Series, MX240, MX480, MX960 19.4 versions prior to 19.4R2-EVO. This issue does not affect the MX10001.
CVE-2021-0264 1 Juniper 21 Junos, Junos Os Evolved, Mx10 and 18 more 2021-04-30 5.0 MEDIUM 7.5 HIGH
A vulnerability in the processing of traffic matching a firewall filter containing a syslog action in Juniper Networks Junos OS on MX Series with MPC10/MPC11 cards installed, PTX10003 and PTX10008 Series devices, will cause the line card to crash and restart, creating a Denial of Service (DoS). Continued receipt and processing of packets matching the firewall filter can create a sustained Denial of Service (DoS) condition. When traffic hits the firewall filter, configured on lo0 or any physical interface on the line card, containing a term with a syslog action (e.g. 'term <name> then syslog'), the affected line card will crash and restart, impacting traffic processing through the ports of the line card. This issue only affects MX Series routers with MPC10 or MPC11 line cards, and PTX10003 or PTX10008 Series packet transport routers. No other platforms or models of line cards are affected by this issue. Note: This issue has also been identified and described in technical service bulletin TSB17931 (login required). This issue affects: Juniper Networks Junos OS on MX Series: 19.3 versions prior to 19.3R3-S2; 19.4 versions prior to 19.4R3-S2; 20.1 versions prior to 20.1R3; 20.2 versions prior to 20.2R2-S2, 20.2R3; 20.3 versions prior to 20.3R3; 20.4 versions prior to 20.4R2. Juniper Networks Junos OS Evolved on PTX10003, PTX10008: All versions prior to 20.4R2-EVO. This issue does not affect Juniper Networks Junos OS versions prior to 19.3R1.
CVE-2021-0251 1 Juniper 17 Junos, Mx10, Mx10003 and 14 more 2021-04-27 5.0 MEDIUM 8.6 HIGH
A NULL Pointer Dereference vulnerability in the Captive Portal Content Delivery (CPCD) services daemon (cpcd) of Juniper Networks Junos OS on MX Series with MS-PIC, MS-SPC3, MS-MIC or MS-MPC allows an attacker to send malformed HTTP packets to the device thereby causing a Denial of Service (DoS), crashing the Multiservices PIC Management Daemon (mspmand) process thereby denying users the ability to login, while concurrently impacting other mspmand services and traffic through the device. Continued receipt and processing of these malformed packets will create a sustained Denial of Service (DoS) condition. While the Services PIC is restarting, all PIC services will be bypassed until the Services PIC completes its boot process. An attacker sending these malformed HTTP packets to the device who is not part of the Captive Portal experience is not able to exploit this issue. This issue is not applicable to MX RE-based CPCD platforms. This issue affects: Juniper Networks Junos OS on MX Series 17.3 version 17.3R1 and later versions prior to 17.4 versions 17.4R2-S9, 17.4R3-S2; 18.1 versions prior to 18.1R3-S9; 18.2 versions prior to 18.2R3-S3; 18.3 versions prior to 18.3R3-S1; 18.4 versions prior to 18.4R3; 19.1 versions prior to 19.1R2-S2, 19.1R3; 19.2 versions prior to 19.2R2; 19.3 versions prior to 19.3R3. This issue does not affect: Juniper Networks Junos OS versions prior to 17.3R1.
CVE-2019-0007 1 Juniper 17 Junos, Mx10, Mx10003 and 14 more 2020-08-24 7.5 HIGH 10.0 CRITICAL
The vMX Series software uses a predictable IP ID Sequence Number. This leaves the system as well as clients connecting through the device susceptible to a family of attacks which rely on the use of predictable IP ID sequence numbers as their base method of attack. This issue was found during internal product security testing. Affected releases are Juniper Networks Junos OS: 15.1 versions prior to 15.1F5 on vMX Series.