Total
73 CVE
CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
---|---|---|---|---|---|
CVE-2022-25428 | 1 Tenda | 2 Ac9, Ac9 Firmware | 2023-08-08 | 10.0 HIGH | 9.8 CRITICAL |
Tenda AC9 v15.03.2.21 was discovered to contain a stack overflow via the deviceId parameter in the saveparentcontrolinfo function. | |||||
CVE-2022-25438 | 1 Tenda | 2 Ac9, Ac9 Firmware | 2023-08-08 | 10.0 HIGH | 9.8 CRITICAL |
Tenda AC9 v15.03.2.21 was discovered to contain a remote command execution (RCE) vulnerability via the SetIPTVCfg function. | |||||
CVE-2022-25431 | 1 Tenda | 2 Ac9, Ac9 Firmware | 2023-08-08 | 10.0 HIGH | 9.8 CRITICAL |
Tenda AC9 v15.03.2.21 was discovered to contain multiple stack overflows via the NPTR, V12, V10 and V11 parameter in the Formsetqosband function. | |||||
CVE-2022-25437 | 1 Tenda | 2 Ac9, Ac9 Firmware | 2023-08-08 | 10.0 HIGH | 9.8 CRITICAL |
Tenda AC9 v15.03.2.21 was discovered to contain a stack overflow via the list parameter in the SetVirtualServerCfg function. | |||||
CVE-2023-37716 | 1 Tenda | 14 Ac10, Ac10 Firmware, Ac1206 and 11 more | 2023-07-21 | N/A | 9.8 CRITICAL |
Tenda F1202 V1.0BR_V1.2.0.20(408) and FH1202_V1.2.0.19_EN, AC10 V1.0, AC1206 V1.0, AC7 V1.0, AC5 V1.0, and AC9 V3.0 were discovered to contain a stack overflow in the page parameter in the function fromNatStaticSetting. | |||||
CVE-2023-37717 | 1 Tenda | 14 Ac10, Ac10 Firmware, Ac1206 and 11 more | 2023-07-21 | N/A | 9.8 CRITICAL |
Tenda F1202 V1.0BR_V1.2.0.20(408) and FH1202_V1.2.0.19_EN, AC10 V1.0, AC1206 V1.0, AC7 V1.0, AC5 V1.0, and AC9 V3.0 were discovered to contain a stack overflow in the page parameter in the function fromDhcpListClient. | |||||
CVE-2022-36571 | 1 Tenda | 2 Ac9, Ac9 Firmware | 2022-09-02 | N/A | 7.2 HIGH |
Tenda AC9 V15.03.05.19 was discovered to contain a stack overflow via the mask parameter at /goform/WanParameterSetting. | |||||
CVE-2022-36570 | 1 Tenda | 2 Ac9, Ac9 Firmware | 2022-09-02 | N/A | 7.2 HIGH |
Tenda AC9 V15.03.05.19 was discovered to contain a stack overflow via the time parameter at /goform/SetLEDCfg. | |||||
CVE-2022-36569 | 1 Tenda | 2 Ac9, Ac9 Firmware | 2022-09-02 | N/A | 8.8 HIGH |
Tenda AC9 V15.03.05.19 was discovered to contain a stack overflow via the deviceList parameter at /goform/setMacFilterCfg. | |||||
CVE-2022-36568 | 1 Tenda | 2 Ac9, Ac9 Firmware | 2022-09-02 | N/A | 8.8 HIGH |
Tenda AC9 V15.03.05.19 was discovered to contain a stack overflow via the list parameter at /goform/setPptpUserList. | |||||
CVE-2021-42659 | 1 Tenda | 2 Ac9, Ac9 Firmware | 2022-07-12 | 6.1 MEDIUM | 6.5 MEDIUM |
There is a buffer overflow vulnerability in the Web server httpd of the router in Tenda router devices such as Tenda AC9 V1.0 V15.03.02.19(6318) and Tenda AC9 V3.0 V15.03.06.42_multi. When setting the virtual service, the httpd program will crash and exit when the super-long list parameter occurs. | |||||
CVE-2022-28560 | 1 Tenda | 2 Ac9, Ac9 Firmware | 2022-05-11 | 10.0 HIGH | 9.8 CRITICAL |
There is a stack overflow vulnerability in the goform/fast_setting_wifi_set function in the httpd service of Tenda ac9 15.03.2.21_cn router. An attacker can obtain a stable shell through a carefully constructed payload | |||||
CVE-2022-27022 | 1 Tenda | 2 Ac9, Ac9 Firmware | 2022-04-14 | 10.0 HIGH | 9.8 CRITICAL |
There is a stack overflow vulnerability in the SetSysTimeCfg() function in the httpd service of Tenda AC9 V15.03.2.21_cn. The attacker can obtain a stable root shell through a constructed payload. | |||||
CVE-2022-27016 | 1 Tenda | 2 Ac9, Ac9 Firmware | 2022-04-14 | 10.0 HIGH | 9.8 CRITICAL |
There is a stack overflow vulnerability in the SetStaticRouteCfg() function in the httpd service of Tenda AC9 15.03.2.21_cn. | |||||
CVE-2022-26278 | 1 Tenda | 2 Ac9, Ac9 Firmware | 2022-04-04 | 10.0 HIGH | 9.8 CRITICAL |
Tenda AC9 v15.03.2.21_cn was discovered to contain a stack overflow via the time parameter in the PowerSaveSet function. | |||||
CVE-2022-25417 | 1 Tenda | 2 Ac9, Ac9 Firmware | 2022-03-03 | 10.0 HIGH | 9.8 CRITICAL |
Tenda AC9 V15.03.2.21_cn was discovered to contain a stack overflow via the function saveparentcontrolinfo. | |||||
CVE-2022-25414 | 1 Tenda | 2 Ac9, Ac9 Firmware | 2022-03-03 | 10.0 HIGH | 9.8 CRITICAL |
Tenda AC9 V15.03.2.21_cn was discovered to contain a stack overflow via the parameter NPTR. | |||||
CVE-2022-25418 | 1 Tenda | 2 Ac9, Ac9 Firmware | 2022-03-03 | 10.0 HIGH | 9.8 CRITICAL |
Tenda AC9 V15.03.2.21_cn was discovered to contain a stack overflow via the function openSchedWifi. | |||||
CVE-2020-26728 | 1 Tenda | 2 Ac9, Ac9 Firmware | 2022-02-22 | 7.5 HIGH | 9.8 CRITICAL |
A vulnerability was discovered in Tenda AC9 v3.0 V15.03.06.42_multi and Tenda AC9 V1.0 V15.03.05.19(6318)_CN which allows for remote code execution via shell metacharacters in the guestuser field to the __fastcall function with a POST request. | |||||
CVE-2018-18729 | 1 Tenda | 10 Ac10, Ac10 Firmware, Ac15 and 7 more | 2019-10-03 | 9.0 HIGH | 9.8 CRITICAL |
An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. There is a heap-based buffer overflow vulnerability in the router's web server -- httpd. While processing the 'mac' parameter for a post request, the value is directly used in a strcpy to a variable placed on the heap, which can leak sensitive information or even hijack program control flow. |