Filtered by vendor Siemens
Subscribe
Total
1983 CVE
CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
---|---|---|---|---|---|
CVE-2022-32257 | 1 Siemens | 1 Sinema Remote Connect Server | 2024-03-25 | N/A | 9.8 CRITICAL |
A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.2). The affected application consists of a web service that lacks proper access control for some of the endpoints. This could lead to unauthorized access to resources and potentially lead to code execution. | |||||
CVE-2024-22045 | 1 Siemens | 1 Sinema Remote Connect Client | 2024-03-25 | N/A | 6.5 MEDIUM |
A vulnerability has been identified in SINEMA Remote Connect Client (All versions < V3.1 SP1). The product places sensitive information into files or directories that are accessible to actors who are allowed to have access to the files, but not to the sensitive information. This information is also available via the web interface of the product. | |||||
CVE-2023-46156 | 1 Siemens | 145 Simatic Drive Controller Cpu 1504d Tf, Simatic Drive Controller Cpu 1504d Tf Firmware, Simatic Drive Controller Cpu 1507d Tf and 142 more | 2024-03-12 | N/A | 7.5 HIGH |
Affected devices improperly handle specially crafted packets sent to port 102/tcp. This could allow an attacker to create a denial of service condition. A restart is needed to restore normal operations. | |||||
CVE-2023-38076 | 1 Siemens | 3 Jt2go, Teamcenter Visualization, Tecnomatix Plant Simulation | 2024-02-16 | N/A | 7.8 HIGH |
A vulnerability has been identified in JT2Go (All versions < V14.3.0.1), Teamcenter Visualization V13.3 (All versions < V13.3.0.12), Teamcenter Visualization V14.0 (All versions), Teamcenter Visualization V14.1 (All versions < V14.1.0.11), Teamcenter Visualization V14.2 (All versions < V14.2.0.6), Teamcenter Visualization V14.3 (All versions < V14.3.0.1), Tecnomatix Plant Simulation V2201 (All versions < V2201.0010), Tecnomatix Plant Simulation V2302 (All versions < V2302.0004). The affected application is vulnerable to heap-based buffer overflow while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-21041) | |||||
CVE-2023-38071 | 1 Siemens | 3 Jt2go, Teamcenter Visualization, Tecnomatix Plant Simulation | 2024-02-16 | N/A | 7.8 HIGH |
A vulnerability has been identified in JT2Go (All versions < V14.3.0.1), Teamcenter Visualization V13.3 (All versions < V13.3.0.12), Teamcenter Visualization V14.0 (All versions), Teamcenter Visualization V14.1 (All versions < V14.1.0.11), Teamcenter Visualization V14.2 (All versions < V14.2.0.6), Teamcenter Visualization V14.3 (All versions < V14.3.0.1), Tecnomatix Plant Simulation V2201 (All versions < V2201.0010), Tecnomatix Plant Simulation V2302 (All versions < V2302.0004). The affected application is vulnerable to heap-based buffer overflow while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-20824) | |||||
CVE-2023-38072 | 1 Siemens | 3 Jt2go, Teamcenter Visualization, Tecnomatix Plant Simulation | 2024-02-16 | N/A | 7.8 HIGH |
A vulnerability has been identified in JT2Go (All versions < V14.3.0.1), Teamcenter Visualization V13.3 (All versions < V13.3.0.12), Teamcenter Visualization V14.0 (All versions), Teamcenter Visualization V14.1 (All versions < V14.1.0.11), Teamcenter Visualization V14.2 (All versions < V14.2.0.6), Teamcenter Visualization V14.3 (All versions < V14.3.0.1), Tecnomatix Plant Simulation V2201 (All versions < V2201.0010), Tecnomatix Plant Simulation V2302 (All versions < V2302.0004). The affected application contains an out of bounds write past the end of an allocated structure while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-20825) | |||||
CVE-2023-38073 | 1 Siemens | 3 Jt2go, Teamcenter Visualization, Tecnomatix Plant Simulation | 2024-02-16 | N/A | 7.8 HIGH |
A vulnerability has been identified in JT2Go (All versions < V14.3.0.1), Teamcenter Visualization V13.3 (All versions < V13.3.0.12), Teamcenter Visualization V14.0 (All versions), Teamcenter Visualization V14.1 (All versions < V14.1.0.11), Teamcenter Visualization V14.2 (All versions < V14.2.0.6), Teamcenter Visualization V14.3 (All versions < V14.3.0.1), Tecnomatix Plant Simulation V2201 (All versions < V2201.0010), Tecnomatix Plant Simulation V2302 (All versions < V2302.0004). The affected application contains a type confusion vulnerability while parsing WRL files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-20826) | |||||
CVE-2023-41032 | 1 Siemens | 2 Parasolid, Simcenter Femap | 2024-02-16 | N/A | 7.8 HIGH |
A vulnerability has been identified in Parasolid V34.1 (All versions < V34.1.258), Parasolid V35.0 (All versions < V35.0.253), Parasolid V35.1 (All versions < V35.1.184), Parasolid V36.0 (All versions < V36.0.142), Simcenter Femap V2301 (All versions < V2301.0003), Simcenter Femap V2306 (All versions < V2306.0001). The affected application contains an out of bounds write past the end of an allocated structure while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-21263) | |||||
CVE-2023-41033 | 1 Siemens | 2 Parasolid, Simcenter Femap | 2024-02-16 | N/A | 7.8 HIGH |
A vulnerability has been identified in Parasolid V35.0 (All versions < V35.0.260), Parasolid V35.1 (All versions < V35.1.246), Parasolid V36.0 (All versions < V36.0.156), Simcenter Femap V2301 (All versions < V2301.0003), Simcenter Femap V2306 (All versions < V2306.0001). The affected application contains an out of bounds write past the end of an allocated structure while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-21266) | |||||
CVE-2003-0190 | 3 Openbsd, Openpkg, Siemens | 6 Openssh, Openpkg, Scalance X204rna and 3 more | 2024-02-15 | 5.0 MEDIUM | N/A |
OpenSSH-portable (OpenSSH) 3.6.1p1 and earlier with PAM support enabled immediately sends an error message when a user does not exist, which allows remote attackers to determine valid usernames via a timing attack. | |||||
CVE-2024-23804 | 1 Siemens | 1 Tecnomatix Plant Simulation | 2024-02-15 | N/A | 7.8 HIGH |
A vulnerability has been identified in Tecnomatix Plant Simulation V2201 (All versions < V2201.0012), Tecnomatix Plant Simulation V2302 (All versions < V2302.0006). The affected applications contain a stack overflow vulnerability while parsing specially crafted PSOBJ files. This could allow an attacker to execute code in the context of the current process. | |||||
CVE-2024-23803 | 1 Siemens | 1 Tecnomatix Plant Simulation | 2024-02-15 | N/A | 7.8 HIGH |
A vulnerability has been identified in Tecnomatix Plant Simulation V2201 (All versions), Tecnomatix Plant Simulation V2302 (All versions < V2302.0007). The affected application contains an out of bounds write past the end of an allocated buffer while parsing a specially crafted SPP file. This could allow an attacker to execute code in the context of the current process. | |||||
CVE-2023-24552 | 1 Siemens | 2 Solid Edge Se2022, Solid Edge Se2023 | 2024-02-14 | N/A | 7.8 HIGH |
A vulnerability has been identified in Solid Edge SE2022 (All versions < V222.0MP12), Solid Edge SE2023 (All versions < V223.0Update2). The affected application contains an out of bounds read past the end of an allocated buffer while parsing a specially crafted PAR file. This could allow an attacker to to execute code in the context of the current process. | |||||
CVE-2006-3344 | 1 Siemens | 1 Speedstream Wireless Router | 2024-02-14 | 7.5 HIGH | N/A |
Siemens Speedstream Wireless Router 2624 allows local users to bypass authentication and access protected files by using the Universal Plug and Play UPnP/1.0 component. | |||||
CVE-2006-3907 | 1 Siemens | 1 Speedstream Wireless Router | 2024-02-14 | 5.0 MEDIUM | N/A |
Siemens SpeedStream 2624 allows remote attackers to cause a denial of service (device hang) by sending a crafted packet to the web administrative interface. | |||||
CVE-2024-23800 | 1 Siemens | 1 Tecnomatix Plant Simulation | 2024-02-13 | N/A | 5.5 MEDIUM |
A vulnerability has been identified in Tecnomatix Plant Simulation V2201 (All versions), Tecnomatix Plant Simulation V2302 (All versions < V2302.0007). The affected applications contain a null pointer dereference vulnerability while parsing specially crafted SPP files. An attacker could leverage this vulnerability to crash the application causing denial of service condition. | |||||
CVE-2024-23801 | 1 Siemens | 1 Tecnomatix Plant Simulation | 2024-02-13 | N/A | 5.5 MEDIUM |
A vulnerability has been identified in Tecnomatix Plant Simulation V2201 (All versions), Tecnomatix Plant Simulation V2302 (All versions < V2302.0007). The affected applications contain a null pointer dereference vulnerability while parsing specially crafted SPP files. An attacker could leverage this vulnerability to crash the application causing denial of service condition. | |||||
CVE-2024-23799 | 1 Siemens | 1 Tecnomatix Plant Simulation | 2024-02-13 | N/A | 5.5 MEDIUM |
A vulnerability has been identified in Tecnomatix Plant Simulation V2201 (All versions), Tecnomatix Plant Simulation V2302 (All versions < V2302.0007). The affected applications contain a null pointer dereference vulnerability while parsing specially crafted SPP files. An attacker could leverage this vulnerability to crash the application causing denial of service condition. | |||||
CVE-2024-23802 | 1 Siemens | 1 Tecnomatix Plant Simulation | 2024-02-13 | N/A | 7.8 HIGH |
A vulnerability has been identified in Tecnomatix Plant Simulation V2201 (All versions < V2201.0012), Tecnomatix Plant Simulation V2302 (All versions < V2302.0006). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted SPP files. This could allow an attacker to execute code in the context of the current process. | |||||
CVE-2024-23798 | 1 Siemens | 1 Tecnomatix Plant Simulation | 2024-02-13 | N/A | 7.8 HIGH |
A vulnerability has been identified in Tecnomatix Plant Simulation V2201 (All versions < V2201.0012), Tecnomatix Plant Simulation V2302 (All versions < V2302.0006). The affected applications contain a stack overflow vulnerability while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process. |