Filtered by vendor Ni
Subscribe
Total
49 CVE
CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
---|---|---|---|---|---|
CVE-2024-10494 | 1 Ni | 1 Labview | 2025-03-04 | N/A | 7.8 HIGH |
An out of bounds read due to improper input validation in HeapObjMapImpl.cpp in NI LabVIEW may disclose information or result in arbitrary code execution. Successful exploitation requires an attacker to provide a user with a specially crafted VI. This vulnerability affects LabVIEW 2024 Q3 and prior versions. | |||||
CVE-2024-23611 | 1 Ni | 1 Labview | 2025-02-27 | N/A | 7.8 HIGH |
An out of bounds write due to a missing bounds check in LabVIEW may result in remote code execution. Successful exploitation requires an attacker to provide a user with a specially crafted VI. This vulnerability affects LabVIEW 2024 Q1 and prior versions. | |||||
CVE-2024-23610 | 1 Ni | 1 Labview | 2025-02-27 | N/A | 7.8 HIGH |
An out of bounds write due to a missing bounds check in LabVIEW may result in remote code execution. Successful exploitation requires an attacker to provide a user with a specially crafted VI. This vulnerability affects LabVIEW 2024 Q1 and prior versions. | |||||
CVE-2023-5136 | 1 Ni | 4 Diadem, Flexlogger, Topografix Data Plugin and 1 more | 2024-10-10 | N/A | 5.5 MEDIUM |
An incorrect permission assignment in the TopoGrafix DataPlugin for GPX could result in information disclosure. An attacker could exploit this vulnerability by getting a user to open a specially crafted data file. | |||||
CVE-2024-6791 | 1 Ni | 1 Veristand | 2024-09-17 | N/A | 7.8 HIGH |
A directory path traversal vulnerability exists when loading a vsmodel file in NI VeriStand that may result in remote code execution. Successful exploitation requires an attacker to get a user to open a specially crafted .vsmodel file. This vulnerability affects VeriStand 2024 Q2 and prior versions. | |||||
CVE-2024-6793 | 1 Ni | 1 Veristand | 2024-09-17 | N/A | 9.8 CRITICAL |
A deserialization of untrusted data vulnerability exists in NI VeriStand DataLogging Server that may result in remote code execution. Successful exploitation requires an attacker to send a specially crafted message. These vulnerabilities affect NI VeriStand 2024 Q2 and prior versions. | |||||
CVE-2024-6794 | 1 Ni | 1 Veristand | 2024-09-17 | N/A | 9.8 CRITICAL |
A deserialization of untrusted data vulnerability exists in NI VeriStand Waveform Streaming Server that may result in remote code execution. Successful exploitation requires an attacker to send a specially crafted message. These vulnerabilities affect NI VeriStand 2024 Q2 and prior versions. | |||||
CVE-2024-6805 | 1 Ni | 1 Veristand | 2024-09-17 | N/A | 9.8 CRITICAL |
The NI VeriStand Gateway is missing authorization checks when an actor attempts to access File Transfer resources. These missing checks may result in information disclosure or remote code execution. This affects NI VeriStand 2024 Q2 and prior versions. | |||||
CVE-2024-6806 | 1 Ni | 1 Veristand | 2024-09-17 | N/A | 9.8 CRITICAL |
The NI VeriStand Gateway is missing authorization checks when an actor attempts to access Project resources. These missing checks may result in remote code execution. This affects NI VeriStand 2024 Q2 and prior versions. | |||||
CVE-2024-6121 | 1 Ni | 2 Flexlogger, Systemlink | 2024-09-12 | N/A | 7.8 HIGH |
An out-of-date version of Redis shipped with NI SystemLink Server is susceptible to multiple vulnerabilities, including CVE-2022-24834. This affects NI SystemLink Server 2024 Q1 and prior versions. It also affects NI FlexLogger 2023 Q2 and prior versions which installed this shared service. | |||||
CVE-2024-4081 | 1 Ni | 1 Labview | 2024-09-12 | N/A | 7.8 HIGH |
A memory corruption issue due to an improper length check in NI LabVIEW may disclose information or result in arbitrary code execution. Successful exploitation requires an attacker to provide a user with a specially crafted VI. This vulnerability affects NI LabVIEW 2024 Q1 and prior versions. | |||||
CVE-2024-6122 | 1 Ni | 2 Flexlogger, Systemlink | 2024-09-10 | N/A | 5.5 MEDIUM |
An incorrect permission in the installation directory for the shared NI SystemLink Server KeyValueDatabase service may result in information disclosure via local access. This affects NI SystemLink Server 2024 Q1 and prior versions. It also affects NI FlexLogger 2023 Q2 and prior versions which installed this shared service. | |||||
CVE-2024-4080 | 1 Ni | 1 Labview | 2024-09-05 | N/A | 7.8 HIGH |
A memory corruption issue due to an improper length check in LabVIEW tdcore.dll may disclose information or result in arbitrary code execution. Successful exploitation requires an attacker to provide a user with a specially crafted VI. This vulnerability affects LabVIEW 2024 Q1 and prior versions. | |||||
CVE-2024-4079 | 1 Ni | 1 Labview | 2024-09-05 | N/A | 7.8 HIGH |
An out of bounds read due to a missing bounds check in LabVIEW may disclose information or result in arbitrary code execution. Successful exploitation requires an attacker to provide a user with a specially crafted VI. This vulnerability affects LabVIEW 2024 Q1 and prior versions. | |||||
CVE-2013-5021 | 2 Abb, Ni | 5 Datamanager, Labview, Labwindows and 2 more | 2023-11-07 | 9.3 HIGH | N/A |
Multiple absolute path traversal vulnerabilities in National Instruments cwui.ocx, as used in National Instruments LabWindows/CVI 2012 SP1 and earlier, National Instruments LabVIEW 2012 SP1 and earlier, the Data Analysis component in ABB DataManager 1 through 6.3.6, and other products allow remote attackers to create and execute arbitrary files via a full pathname in an argument to the ExportStyle method in the (1) CWNumEdit, (2) CWGraph, (3) CWBoolean, (4) CWSlide, or (5) CWKnob ActiveX control, in conjunction with file content in the (a) Caption or (b) FormatString property value. | |||||
CVE-2023-4601 | 2 Microsoft, Ni | 2 Windows, System Configuration | 2023-10-28 | N/A | 9.8 CRITICAL |
A stack-based buffer overflow vulnerability exists in NI System Configuration that could result in information disclosure and/or arbitrary code execution. Successful exploitation requires that an attacker can provide a specially crafted response. This affects NI System Configuration 2023 Q3 and all previous versions. | |||||
CVE-2023-4570 | 1 Ni | 1 Measurementlink | 2023-10-12 | N/A | 8.8 HIGH |
An improper access restriction in NI MeasurementLink Python services could allow an attacker on an adjacent network to reach services exposed on localhost. These services were previously thought to be unreachable outside of the node. This affects measurement plug-ins written in Python using version 1.1.0 of the ni-measurementlink-service Python package and all previous versions. | |||||
CVE-2022-35415 | 1 Ni | 1 Configuration Manager | 2022-09-17 | N/A | 7.8 HIGH |
An improper input validation in NI System Configuration Manager before 22.5 may allow a privileged user to potentially enable escalation of privilege via local access. | |||||
CVE-2022-27237 | 1 Ni | 5 Flexlogger, G Web Development Software, Labview and 2 more | 2022-05-03 | 4.3 MEDIUM | 6.1 MEDIUM |
There is a cross-site scripting (XSS) vulnerability in an NI Web Server component installed with several NI products. Depending on the product(s) in use, remediation guidance includes: install SystemLink version 2021 R3 or later, install FlexLogger 2022 Q2 or later, install LabVIEW 2021 SP1, install G Web Development 2022 R1 or later, or install Static Test Software Suite version 1.2 or later. | |||||
CVE-2017-2779 | 1 Ni | 1 Labview | 2022-04-19 | 6.8 MEDIUM | 7.8 HIGH |
An exploitable memory corruption vulnerability exists in the RSRC segment parsing functionality of LabVIEW 2017, LabVIEW 2016, LabVIEW 2015, and LabVIEW 2014. A specially crafted Virtual Instrument (VI) file can cause an attacker controlled looping condition resulting in an arbitrary null write. An attacker controlled VI file can be used to trigger this vulnerability and can potentially result in code execution. |