CVE-2024-2011 1 Hitachienergy 2 Foxman-un, Unem 2024-08-15 N/A 9.8 CRITICAL
A heap-based buffer overflow vulnerability exists in the FOXMAN-UN/UNEM that if exploited will generally lead to a denial of service but can be used to execute arbitrary code, which is usually outside the scope of a program's implicit security policy
CVE-2024-2012 1 Hitachienergy 2 Foxman-un, Unem 2024-08-15 N/A 9.8 CRITICAL
vulnerability exists in the FOXMAN-UN/UNEM server / API Gateway that if exploited an attacker could use to allow unintended commands or code to be executed on the UNEM server allowing sensitive data to be read or modified or could cause other unintended behavior
CVE-2024-2013 1 Hitachienergy 2 Foxman-un, Unem 2024-08-15 N/A 10.0 CRITICAL
An authentication bypass vulnerability exists in the FOXMAN-UN/UNEM server / API Gateway component that if exploited allows attackers without any access to interact with the services and the post-authentication attack surface.
CVE-2023-1711 1 Hitachienergy 2 Foxman-un, Unem 2024-07-25 N/A 4.4 MEDIUM
A vulnerability exists in a FOXMAN-UN and UNEM logging component, it only affects systems that use remote authentication to the network elements. If exploited an attacker could obtain confidential information. List of CPEs: * cpe:2.3:a:hitachienergy:foxman_un:R9C:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:foxman_un:R10C:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:foxman_un:R11A:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:foxman_un:R11B:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:foxman_un:R14A:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:foxman_un:R14B:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:foxman_un:R15A:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:foxman_un:R15B:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:foxman_un:R16A:*:*:*:*:*:*:* * * cpe:2.3:a:hitachienergy:unem:R9C:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy: unem :R10C:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy: unem :R11A:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy: unem :R11B:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy: unem :R14A:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy: unem :R14B:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy: unem :R15A:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy: unem :R15B:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy: unem :R16A:*:*:*:*:*:*:*
CVE-2022-2513 1 Hitachienergy 6 650connectivitypackage, 670connectivitypackage, Gms600connectivitypackage and 3 more 2024-05-28 N/A 5.5 MEDIUM
A vulnerability exists in the Intelligent Electronic Device (IED) Connectivity Package (ConnPack) credential storage function in Hitachi Energy’s PCM600 product included in the versions listed below, where IEDs credentials are stored in a cleartext format in the PCM600 database and logs files. An attacker having get access to the exported backup file can exploit the vulnerability and obtain user credentials of the IEDs. Additionally, an attacker with administrator access to the PCM600 host machine can obtain other user credentials by analyzing database log files. The credentials may be used to perform unauthorized modifications such as loading incorrect configurations, reboot the IEDs or cause a denial-of-service on the IEDs.
CVE-2022-3864 1 Hitachienergy 6 Relion 650, Relion 650 Firmware, Relion 670 and 3 more 2024-01-10 N/A 4.5 MEDIUM
A vulnerability exists in the Relion update package signature validation. A tampered update package could cause the IED to restart. After restart the device is back to normal operation. An attacker could exploit the vulnerability by first gaining access to the system with security privileges and attempt to update the IED with a malicious update package. Successful exploitation of this vulnerability will cause the IED to restart, causing a temporary Denial of Service.
CVE-2023-1514 1 Hitachienergy 1 Rtu500 Scripting Interface 2023-12-28 N/A 7.5 HIGH
A vulnerability exists in the component RTU500 Scripting interface. When a client connects to a server using TLS, the server presents a certificate. This certificate links a public key to the identity of the service and is signed by a Certification Authority (CA), allowing the client to validate that the remote service can be trusted and is not malicious. If the client does not validate the parameters of the certificate, then attackers could be able to spoof the identity of the service. An attacker could exploit the vulnerability by using faking the identity of a RTU500 device and intercepting the messages initiated via the RTU500 Scripting interface.
CVE-2023-5769 1 Hitachienergy 8 Rtu520, Rtu520 Firmware, Rtu530 and 5 more 2023-12-18 N/A 6.1 MEDIUM
A vulnerability exists in the webserver that affects the RTU500 series product versions listed below. A malicious actor could perform cross-site scripting on the webserver due to user input being improperly sanitized.
CVE-2023-5768 1 Hitachienergy 8 Rtu520, Rtu520 Firmware, Rtu530 and 5 more 2023-12-07 N/A 6.1 MEDIUM
A vulnerability exists in the HCI IEC 60870-5-104 that affects the RTU500 series product versions listed below. Incomplete or wrong received APDU frame layout may cause blocking on link layer. Error reason was an endless blocking when reading incoming frames on link layer with wrong length information of APDU or delayed reception of data octets. Only communication link of affected HCI IEC 60870-5-104 is blocked. If attack sequence stops the communication to the previously attacked link gets normal again.
CVE-2023-5767 1 Hitachienergy 8 Rtu520, Rtu520 Firmware, Rtu530 and 5 more 2023-12-07 N/A 6.1 MEDIUM
A vulnerability exists in the webserver that affects the RTU500 series product versions listed below. A malicious actor could perform cross-site scripting on the webserver due to an RDT language file being improperly sanitized.
CVE-2023-2621 1 Hitachienergy 1 Modular Advanced Control For Hvdc 2023-11-08 N/A 6.5 MEDIUM
The McFeeder server (distributed as part of SSW package), is susceptible to an arbitrary file write vulnerability on the MAIN computer system. This vulnerability stems from the use of an outdated version of a third-party library, which is used to extract archives uploaded to McFeeder server. An authenticated malicious client can exploit this vulnerability by uploading a crafted ZIP archive via the network to McFeeder’s service endpoint.
CVE-2023-2622 1 Hitachienergy 1 Modular Advanced Control For Hvdc 2023-11-08 N/A 4.3 MEDIUM
Authenticated clients can read arbitrary files on the MAIN Computer system using the remote procedure call (RPC) of the InspectSetup service endpoint. The low privilege client is then allowed to read arbitrary files that they do not have authorization to read.
CVE-2023-5516 1 Hitachienergy 1 Esoms 2023-11-08 N/A 5.3 MEDIUM
Poorly constructed webap requests and URI components with special characters trigger unhandled errors and exceptions, disclosing information about the underlying technology and other sensitive information details. The website unintentionally reveals sensitive information including technical details like version Info, endpoints, backend server, Internal IP. etc., which can potentially expose additional attack surface containing other interesting vulnerabilities.
CVE-2023-5514 1 Hitachienergy 1 Esoms 2023-11-08 N/A 5.3 MEDIUM
The response messages received from the eSOMS report generation using certain parameter queries with full file path can be abused for enumerating the local file system structure.
CVE-2023-5515 1 Hitachienergy 1 Esoms 2023-11-08 N/A 5.3 MEDIUM
The responses for web queries with certain parameters disclose internal path of resources. This information can be used to learn internal structure of the application and to further plot attacks against web servers and deployed web applications.
CVE-2022-3353 1 Hitachienergy 25 Fox615 Tego1, Fox615 Tego1 Firmware, Gms600 and 22 more 2023-11-07 N/A 7.5 HIGH
A vulnerability exists in the IEC 61850 communication stack that affects multiple Hitachi Energy products.  An attacker could exploit the vulnerability by using a specially crafted message sequence, to force the IEC 61850 MMS-server communication stack, to stop accepting new MMS-client connections.  Already existing/established client-server connections are not affected. List of affected CPEs: * cpe:2.3:o:hitachienergy:fox61x_tego1:r15b08:*:*:*:*:*:*:* * cpe:2.3:o:hitachienergy:fox61x_tego1:r2a16_3:*:*:*:*:*:*:* * cpe:2.3:o:hitachienergy:fox61x_tego1:r2a16:*:*:*:*:*:*:* * cpe:2.3:o:hitachienergy:fox61x_tego1:r1e01:*:*:*:*:*:*:* * cpe:2.3:o:hitachienergy:fox61x_tego1:r1d02:*:*:*:*:*:*:* * cpe:2.3:o:hitachienergy:fox61x_tego1:r1c07:*:*:*:*:*:*:* * cpe:2.3:o:hitachienergy:fox61x_tego1:r1b02:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:gms600:1.3.0:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:itt600_sa_explorer:1.1.*:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:itt600_sa_explorer:1.5.*:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:itt600_sa_explorer:1.6.0:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:itt600_sa_explorer:1.6.0.1:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:itt600_sa_explorer:1.7.0:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:itt600_sa_explorer:1.7.2:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:itt600_sa_explorer:1.8.0:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:itt600_sa_explorer:2.0.*:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:itt600_sa_explorer:2.1.0.4:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:itt600_sa_explorer:2.1.0.5:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:microscada_x_sys600:10:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:microscada_x_sys600:10.*:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2.1:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3.1:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:microscada_x_sys600:10.4:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:microscada_x_sys600:10.4.1:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:mms:2.2.3:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:pwc600:1.0:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:pwc600:1.1:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:pwc600:1.2:*:*:*:*:*:*:* * cpe:2.3:o:hitachienergy:reb500:7:*:*:*:*:*:*:*:* * cpe:2.3:o:hitachienergy:reb500:8:*:*:*:*:*:*:* * cpe:2.3:o:hitachienergy:relion670:1.2.*:*:*:*:*:*:*:* * cpe:2.3:o:hitachienergy:relion670:2.0.*:*:*:*:*:*:*:* * cpe:2.3:o:hitachienergy:relion650:1.1.*:*:*:*:*:*:*:* * cpe:2.3:o:hitachienergy:relion650:1.3.*:*:*:*:*:*:*:* * cpe:2.3:o:hitachienergy:relion650:2.1.*:*:*:*:*:*:*:* * cpe:2.3:o:hitachienergy:relion670:2.1.*:*:*:*:*:*:*:* * cpe:2.3:o:hitachienergy:relionSAM600-IO:2.2.1:*:*:*:*:*:*:* * cpe:2.3:o:hitachienergy:relionSAM600-IO:2.2.5:*:*:*:*:*:*:* * cpe:2.3:o:hitachienergy:relion670:2.2.*:*:*:*:*:*:*:* * cpe:2.3:o:hitachienergy:relion650:2.2.*:*:*:*:*:*:*:* * cpe:2.3:o:hitachienergy:rtu500cmu:12.*.*:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:rtu500cmu:13.*.*:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:txpert_hub_coretec_4:2.*:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:txpert_hub_coretec_4:3.0:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:txpert_hub_coretec_5:3.0:*:*:*:*:*:*:*
CVE-2022-3928 1 Hitachienergy 2 Foxman-un, Unem 2023-11-07 N/A 5.5 MEDIUM
Hardcoded credential is found in affected products' message queue. An attacker that manages to exploit this vulnerability will be able to access data to the internal message queue. This issue affects * FOXMAN-UN product: FOXMAN-UN R15B, FOXMAN-UN R15A, FOXMAN-UN R14B, FOXMAN-UN R14A, FOXMAN-UN R11B, FOXMAN-UN R11A, FOXMAN-UN R10C, FOXMAN-UN R9C; * UNEM product: UNEM R15B, UNEM R15A, UNEM R14B, UNEM R14A, UNEM R11B, UNEM R11A, UNEM R10C, UNEM R9C. List of CPEs: * cpe:2.3:a:hitachienergy:foxman-un:R15B:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:foxman-un:R15A:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:foxman-un:R14B:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:foxman-un:R14A:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:foxman-un:R11B:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:foxman-un:R11A:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:foxman-un:R10C:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:foxman-un:R9C:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:unem:R15B:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:unem:R15A:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:unem:R14B:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:unem:R14A:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:unem:R11B:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:unem:R11A:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:unem:R10C:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:unem:R9C:*:*:*:*:*:*:*
CVE-2022-3685 1 Hitachienergy 1 Sdm600 2023-11-07 N/A 7.2 HIGH
A vulnerability exists in the SDM600 software. The software operates at a privilege level that is higher than the minimum level required. An attacker who successfully exploits this vulnerability can escalate privileges. This issue affects: All SDM600 versions prior to version 1.3.0. List of CPEs: * cpe:2.3:a:hitachienergy:sdm600:1.0:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.1:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.9002.257:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.10002.257:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.11002.149:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.12002.222:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.13002.72:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.14002.44:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.14002.92:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.14002.108:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.14002.182:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.14002.257:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.14002.342:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.14002.447:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.14002.481:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.14002.506:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.14002.566:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.20000.3174:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.21000.291:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.21000.931:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.21000.105:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.23000.291:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.3.0.1339:*:*:*:*:*:*:*
CVE-2022-3682 1 Hitachienergy 1 Sdm600 2023-11-07 N/A 8.8 HIGH
A vulnerability exists in the SDM600 file permission validation. An attacker could exploit the vulnerability by gaining access to the system and uploading a specially crafted message to the system node, which could result in Arbitrary code Executing. This issue affects: All SDM600 versions prior to version 1.2 FP3 HF4 (Build Nr. 1.2.23000.291) List of CPEs: * cpe:2.3:a:hitachienergy:sdm600:1.0:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.1:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.9002.257:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.10002.257:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.11002.149:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.12002.222:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.13002.72:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.14002.44:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.14002.92:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.14002.108:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.14002.182:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.14002.257:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.14002.342:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.14002.447:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.14002.481:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.14002.506:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.14002.566:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.20000.3174:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.21000.291:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.21000.931:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.21000.105:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.23000.291:*:*:*:*:*:*:*
CVE-2022-3683 1 Hitachienergy 1 Sdm600 2023-11-07 N/A 7.5 HIGH
A vulnerability exists in the SDM600 API web services authorization validation implementation. An attacker who successfully exploits the vulnerability could read data directly from a data store that is not restricted, or insufficiently protected, having access to sensitive data. This issue affects: All SDM600 versions prior to version 1.2 FP3 HF4 (Build Nr. 1.2.23000.291) List of CPEs: * cpe:2.3:a:hitachienergy:sdm600:1.0:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.1:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.9002.257:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.10002.257:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.11002.149:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.12002.222:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.13002.72:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.14002.44:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.14002.92:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.14002.108:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.14002.182:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.14002.257:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.14002.342:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.14002.447:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.14002.481:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.14002.506:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.14002.566:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.20000.3174:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.21000.291:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.21000.931:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.21000.105:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.23000.291:*:*:*:*:*:*:*