Total
71 CVE
CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
---|---|---|---|---|---|
CVE-2022-40965 | 1 Deltaww | 1 Diaenergie | 2022-10-28 | N/A | 5.4 MEDIUM |
The affected product DIAEnergie (versions prior to v1.9.01.002) is vulnerable to a stored cross-site scripting vulnerability through the PostEnergyType API. | |||||
CVE-2022-40967 | 1 Deltaww | 1 Diaenergie | 2022-10-28 | N/A | 8.8 HIGH |
The affected product DIAEnergie (versions prior to v1.9.01.002) is vulnerable to a SQL injection that exists in CheckIoTHubNameExisted. A low-privileged authenticated attacker could exploit this issue to inject arbitrary SQL queries. | |||||
CVE-2022-41555 | 1 Deltaww | 1 Diaenergie | 2022-10-28 | N/A | 5.4 MEDIUM |
The affected product DIAEnergie (versions prior to v1.9.01.002) is vulnerable to a stored cross-site scripting vulnerability through the PutLineMessageSetting API. | |||||
CVE-2022-41133 | 1 Deltaww | 1 Diaenergie | 2022-10-28 | N/A | 8.8 HIGH |
The affected product DIAEnergie (versions prior to v1.9.01.002) is vulnerable to a SQL injection that exists in GetDIAE_line_message_settingsListParameters. A low-privileged authenticated attacker could exploit this issue to inject arbitrary SQL queries. | |||||
CVE-2022-41651 | 1 Deltaww | 1 Diaenergie | 2022-10-28 | N/A | 5.4 MEDIUM |
The affected product DIAEnergie (versions prior to v1.9.01.002) is vulnerable to a stored cross-site scripting vulnerability through the SetPF API. | |||||
CVE-2022-41701 | 1 Deltaww | 1 Diaenergie | 2022-10-28 | N/A | 5.4 MEDIUM |
The affected product DIAEnergie (versions prior to v1.9.01.002) is vulnerable to a stored cross-site scripting vulnerability through the PutShift API. | |||||
CVE-2022-41702 | 1 Deltaww | 1 Diaenergie | 2022-10-28 | N/A | 5.4 MEDIUM |
The affected product DIAEnergie (versions prior to v1.9.01.002) is vulnerable to a stored cross-site scripting vulnerability through the InsertReg API. | |||||
CVE-2022-41773 | 1 Deltaww | 1 Diaenergie | 2022-10-28 | N/A | 8.8 HIGH |
The affected product DIAEnergie (versions prior to v1.9.01.002) is vulnerable to a SQL injection that exists in CheckDIACloud. A low-privileged authenticated attacker could exploit this issue to inject arbitrary SQL queries. | |||||
CVE-2022-33005 | 1 Deltaww | 1 Diaenergie | 2022-07-06 | 4.3 MEDIUM | 6.1 MEDIUM |
A cross-site scripting (XSS) vulnerability in the System Settings/IOT Settings module of Delta Electronics DIAEnergie v1.08.00 allows attackers to execute arbitrary web scripts via a crafted payload injected into the Name text field. | |||||
CVE-2021-32967 | 1 Deltaww | 1 Diaenergie | 2022-07-02 | 10.0 HIGH | 9.8 CRITICAL |
Delta Electronics DIAEnergie Version 1.7.5 and prior may allow an attacker to add a new administrative user without being authenticated or authorized, which may allow the attacker to log in and use the device with administrative privileges. | |||||
CVE-2022-26338 | 1 Deltaww | 1 Diaenergie | 2022-06-29 | 10.0 HIGH | 9.8 CRITICAL |
Delta Electronics DIAEnergie (All versions prior to 1.8.02.004) has a blind SQL injection vulnerability exists in HandlerPageP_KID.ashx. This allows an attacker to inject arbitrary SQL queries, retrieve and modify database contents, and execute system commands. | |||||
CVE-2022-26887 | 1 Deltaww | 1 Diaenergie | 2022-06-29 | 10.0 HIGH | 9.8 CRITICAL |
Delta Electronics DIAEnergie (All versions prior to 1.8.02.004) has a blind SQL injection vulnerability exists in DIAE_loopmapHandler.ashx. This allows an attacker to inject arbitrary SQL queries, retrieve and modify database contents, and execute system commands. | |||||
CVE-2022-26065 | 1 Deltaww | 1 Diaenergie | 2022-06-29 | 10.0 HIGH | 9.8 CRITICAL |
Delta Electronics DIAEnergie (All versions prior to 1.8.02.004) has a blind SQL injection vulnerability exists in GetLatestDemandNode. This allows an attacker to inject arbitrary SQL queries, retrieve and modify database contents, and execute system commands. | |||||
CVE-2022-26666 | 1 Deltaww | 1 Diaenergie | 2022-06-29 | 10.0 HIGH | 9.8 CRITICAL |
Delta Electronics DIAEnergie (All versions prior to 1.8.02.004) has a blind SQL injection vulnerability exists in HandlerECC.ashx. This allows an attacker to inject arbitrary SQL queries, retrieve and modify database contents, and execute system commands. | |||||
CVE-2022-25880 | 1 Deltaww | 1 Diaenergie | 2022-06-29 | 10.0 HIGH | 9.8 CRITICAL |
Delta Electronics DIAEnergie (All versions prior to 1.8.02.004) has a blind SQL injection vulnerability exists in HandlerTag_KID.ashx. This allows an attacker to inject arbitrary SQL queries, retrieve and modify database contents, and execute system commands. | |||||
CVE-2022-1378 | 1 Deltaww | 1 Diaenergie | 2022-05-11 | 10.0 HIGH | 9.8 CRITICAL |
Delta Electronics DIAEnergie (All versions prior to 1.8.02.004) has a blind SQL injection vulnerability exists in DIAE_pgHandler.ashx. This allows an attacker to inject arbitrary SQL queries, retrieve and modify database contents, and execute system commands. | |||||
CVE-2022-1377 | 1 Deltaww | 1 Diaenergie | 2022-05-11 | 10.0 HIGH | 9.8 CRITICAL |
Delta Electronics DIAEnergie (All versions prior to 1.8.02.004) has a blind SQL injection vulnerability exists in DIAE_rltHandler.ashx. This allows an attacker to inject arbitrary SQL queries, retrieve and modify database contents, and execute system commands. | |||||
CVE-2022-1376 | 1 Deltaww | 1 Diaenergie | 2022-05-10 | 10.0 HIGH | 9.8 CRITICAL |
Delta Electronics DIAEnergie (All versions prior to 1.8.02.004) has a blind SQL injection vulnerability exists in DIAE_privgrpHandler.ashx. This allows an attacker to inject arbitrary SQL queries, retrieve and modify database contents, and execute system commands. | |||||
CVE-2022-1375 | 1 Deltaww | 1 Diaenergie | 2022-05-10 | 10.0 HIGH | 9.8 CRITICAL |
Delta Electronics DIAEnergie (All versions prior to 1.8.02.004) has a blind SQL injection vulnerability exists in DIAE_slogHandler.ashx. This allows an attacker to inject arbitrary SQL queries, retrieve and modify database contents, and execute system commands. | |||||
CVE-2022-1374 | 1 Deltaww | 1 Diaenergie | 2022-05-10 | 10.0 HIGH | 9.8 CRITICAL |
Delta Electronics DIAEnergie (All versions prior to 1.8.02.004) has a blind SQL injection vulnerability exists in DIAE_unHandler.ashx. This allows an attacker to inject arbitrary SQL queries, retrieve and modify database contents, and execute system commands. |