Filtered by vendor Siemens
Subscribe
Total
1983 CVE
CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
---|---|---|---|---|---|
CVE-2024-41940 | 1 Siemens | 1 Sinec Nms | 2024-08-14 | N/A | 9.1 CRITICAL |
A vulnerability has been identified in SINEC NMS (All versions < V3.0). The affected application does not properly validate user input to a privileged command queue. This could allow an authenticated attacker to execute OS commands with elevated privileges. | |||||
CVE-2024-41939 | 1 Siemens | 1 Sinec Nms | 2024-08-14 | N/A | 8.8 HIGH |
A vulnerability has been identified in SINEC NMS (All versions < V3.0). The affected application does not properly enforce authorization checks. This could allow an authenticated attacker to bypass the checks and elevate their privileges on the application. | |||||
CVE-2024-41938 | 1 Siemens | 1 Sinec Nms | 2024-08-14 | N/A | 3.8 LOW |
A vulnerability has been identified in SINEC NMS (All versions < V3.0). The importCertificate function of the SINEC NMS Control web application contains a path traversal vulnerability. This could allow an authenticated attacker it to delete arbitrary certificate files on the drive SINEC NMS is installed on. | |||||
CVE-2024-41907 | 1 Siemens | 1 Sinec Traffic Analyzer | 2024-08-14 | N/A | 5.4 MEDIUM |
A vulnerability has been identified in SINEC Traffic Analyzer (6GK8822-1BG01-0BA0) (All versions < V2.0). The affected application is missing general HTTP security headers in the web server. This could allow an attacker to make the servers more prone to clickjacking attack. | |||||
CVE-2024-41906 | 1 Siemens | 1 Sinec Traffic Analyzer | 2024-08-14 | N/A | 6.5 MEDIUM |
A vulnerability has been identified in SINEC Traffic Analyzer (6GK8822-1BG01-0BA0) (All versions < V2.0). The affected application does not properly handle cacheable HTTP responses in the web service. This could allow an attacker to read and modify data stored in the local cache. | |||||
CVE-2024-41905 | 1 Siemens | 1 Sinec Traffic Analyzer | 2024-08-14 | N/A | 6.5 MEDIUM |
A vulnerability has been identified in SINEC Traffic Analyzer (6GK8822-1BG01-0BA0) (All versions < V2.0). The affected application do not have access control for accessing the files. This could allow an authenticated attacker with low privilege's to get access to sensitive information. | |||||
CVE-2023-26293 | 1 Siemens | 1 Tia Portal | 2024-08-13 | N/A | 7.3 HIGH |
A vulnerability has been identified in Totally Integrated Automation Portal (TIA Portal) V15 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions < V16 Update 7), Totally Integrated Automation Portal (TIA Portal) V17 (All versions < V17 Update 6), Totally Integrated Automation Portal (TIA Portal) V18 (All versions < V18 Update 1). Affected products contain a path traversal vulnerability that could allow the creation or overwrite of arbitrary files in the engineering system. If the user is tricked to open a malicious PC system configuration file, an attacker could exploit this vulnerability to achieve arbitrary code execution. | |||||
CVE-2023-49692 | 1 Siemens | 40 6gk5615-0aa00-2aa2, 6gk5615-0aa00-2aa2 Firmware, 6gk5615-0aa01-2aa2 and 37 more | 2024-08-13 | N/A | 6.7 MEDIUM |
A vulnerability has been identified in RUGGEDCOM RM1224 LTE(4G) EU (6GK6108-4AM00-2BA2) (All versions < V7.2.2), RUGGEDCOM RM1224 LTE(4G) NAM (6GK6108-4AM00-2DA2) (All versions < V7.2.2), SCALANCE M804PB (6GK5804-0AP00-2AA2) (All versions < V7.2.2), SCALANCE M812-1 ADSL-Router (6GK5812-1AA00-2AA2) (All versions < V7.2.2), SCALANCE M812-1 ADSL-Router (6GK5812-1BA00-2AA2) (All versions < V7.2.2), SCALANCE M816-1 ADSL-Router (6GK5816-1AA00-2AA2) (All versions < V7.2.2), SCALANCE M816-1 ADSL-Router (6GK5816-1BA00-2AA2) (All versions < V7.2.2), SCALANCE M826-2 SHDSL-Router (6GK5826-2AB00-2AB2) (All versions < V7.2.2), SCALANCE M874-2 (6GK5874-2AA00-2AA2) (All versions < V7.2.2), SCALANCE M874-3 (6GK5874-3AA00-2AA2) (All versions < V7.2.2), SCALANCE M876-3 (6GK5876-3AA02-2BA2) (All versions < V7.2.2), SCALANCE M876-3 (ROK) (6GK5876-3AA02-2EA2) (All versions < V7.2.2), SCALANCE M876-4 (6GK5876-4AA10-2BA2) (All versions < V7.2.2), SCALANCE M876-4 (EU) (6GK5876-4AA00-2BA2) (All versions < V7.2.2), SCALANCE M876-4 (NAM) (6GK5876-4AA00-2DA2) (All versions < V7.2.2), SCALANCE MUM853-1 (EU) (6GK5853-2EA00-2DA1) (All versions < V7.2.2), SCALANCE MUM856-1 (EU) (6GK5856-2EA00-3DA1) (All versions < V7.2.2), SCALANCE MUM856-1 (RoW) (6GK5856-2EA00-3AA1) (All versions < V7.2.2), SCALANCE S615 EEC LAN-Router (6GK5615-0AA01-2AA2) (All versions < V7.2.2), SCALANCE S615 LAN-Router (6GK5615-0AA00-2AA2) (All versions < V7.2.2). An Improper Neutralization of Special Elements used in an OS Command with root privileges vulnerability exists in the parsing of the IPSEC configuration. This could allow malicious local administrators to issue commands on system level after a new connection is established. | |||||
CVE-2023-49691 | 1 Siemens | 40 6gk5615-0aa00-2aa2, 6gk5615-0aa00-2aa2 Firmware, 6gk5615-0aa01-2aa2 and 37 more | 2024-08-13 | N/A | 6.7 MEDIUM |
A vulnerability has been identified in RUGGEDCOM RM1224 LTE(4G) EU (6GK6108-4AM00-2BA2) (All versions < V8.0), RUGGEDCOM RM1224 LTE(4G) NAM (6GK6108-4AM00-2DA2) (All versions < V8.0), SCALANCE M804PB (6GK5804-0AP00-2AA2) (All versions < V8.0), SCALANCE M812-1 ADSL-Router (6GK5812-1AA00-2AA2) (All versions < V8.0), SCALANCE M812-1 ADSL-Router (6GK5812-1BA00-2AA2) (All versions < V8.0), SCALANCE M816-1 ADSL-Router (6GK5816-1AA00-2AA2) (All versions < V8.0), SCALANCE M816-1 ADSL-Router (6GK5816-1BA00-2AA2) (All versions < V8.0), SCALANCE M826-2 SHDSL-Router (6GK5826-2AB00-2AB2) (All versions < V8.0), SCALANCE M874-2 (6GK5874-2AA00-2AA2) (All versions < V8.0), SCALANCE M874-3 (6GK5874-3AA00-2AA2) (All versions < V8.0), SCALANCE M876-3 (6GK5876-3AA02-2BA2) (All versions < V8.0), SCALANCE M876-3 (ROK) (6GK5876-3AA02-2EA2) (All versions < V8.0), SCALANCE M876-4 (6GK5876-4AA10-2BA2) (All versions < V8.0), SCALANCE M876-4 (EU) (6GK5876-4AA00-2BA2) (All versions < V8.0), SCALANCE M876-4 (NAM) (6GK5876-4AA00-2DA2) (All versions < V8.0), SCALANCE MUM853-1 (EU) (6GK5853-2EA00-2DA1) (All versions < V8.0), SCALANCE MUM856-1 (EU) (6GK5856-2EA00-3DA1) (All versions < V8.0), SCALANCE MUM856-1 (RoW) (6GK5856-2EA00-3AA1) (All versions < V8.0), SCALANCE S615 EEC LAN-Router (6GK5615-0AA01-2AA2) (All versions < V8.0), SCALANCE S615 LAN-Router (6GK5615-0AA00-2AA2) (All versions < V8.0). An Improper Neutralization of Special Elements used in an OS Command with root privileges vulnerability exists in the handling of the DDNS configuration. This could allow malicious local administrators to issue commands on system level after a successful IP address update. | |||||
CVE-2023-38529 | 1 Siemens | 2 Parasolid, Teamcenter Visualization | 2024-08-13 | N/A | 7.8 HIGH |
A vulnerability has been identified in Parasolid V34.1 (All versions < V34.1.258), Parasolid V35.0 (All versions < V35.0.254), Parasolid V35.1 (All versions < V35.1.184), Teamcenter Visualization V14.1 (All versions), Teamcenter Visualization V14.2 (All versions < V14.2.0.12), Teamcenter Visualization V14.3 (All versions < V14.3.0.9), Teamcenter Visualization V2312 (All versions < V2312.0004). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process. | |||||
CVE-2023-38527 | 1 Siemens | 2 Parasolid, Teamcenter Visualization | 2024-08-13 | N/A | 7.8 HIGH |
A vulnerability has been identified in Parasolid V34.1 (All versions < V34.1.258), Parasolid V35.0 (All versions < V35.0.254), Teamcenter Visualization V14.1 (All versions), Teamcenter Visualization V14.2 (All versions < V14.2.0.12), Teamcenter Visualization V14.3 (All versions < V14.3.0.9), Teamcenter Visualization V2312 (All versions < V2312.0004). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process. | |||||
CVE-2023-38531 | 1 Siemens | 2 Parasolid, Teamcenter Visualization | 2024-08-13 | N/A | 7.8 HIGH |
A vulnerability has been identified in Parasolid V34.1 (All versions < V34.1.258), Parasolid V35.0 (All versions < V35.0.254), Parasolid V35.1 (All versions < V35.1.184), Teamcenter Visualization V14.1 (All versions), Teamcenter Visualization V14.2 (All versions < V14.2.0.12), Teamcenter Visualization V14.3 (All versions < V14.3.0.9), Teamcenter Visualization V2312 (All versions < V2312.0004). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process. | |||||
CVE-2023-44321 | 1 Siemens | 142 6ag1206-2bb00-7ac2, 6ag1206-2bb00-7ac2 Firmware, 6ag1206-2bs00-7ac2 and 139 more | 2024-08-13 | N/A | 6.5 MEDIUM |
Affected devices do not properly validate the length of inputs when performing certain configuration changes in the web interface allowing an authenticated attacker to cause a denial of service condition. The device needs to be restarted for the web interface to become available again. | |||||
CVE-2022-35868 | 1 Siemens | 2 Tia Multiuser Server, Tia Project-server | 2024-08-13 | N/A | 6.7 MEDIUM |
A vulnerability has been identified in TIA Multiuser Server V14 (All versions), TIA Multiuser Server V15 (All versions < V15.1 Update 8), TIA Project-Server (All versions < V1.1), TIA Project-Server V16 (All versions), TIA Project-Server V17 (All versions < V17 Update 6). Affected applications contain an untrusted search path vulnerability that could allow an attacker to escalate privileges, when tricking a legitimate user to start the service from an attacker controlled path. | |||||
CVE-2024-39876 | 1 Siemens | 1 Sinema Remote Connect Server | 2024-08-07 | N/A | 4.0 MEDIUM |
A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.2 SP1). Affected applications do not properly handle log rotation. This could allow an unauthenticated remote attacker to cause a denial of service condition through resource exhaustion on the device. | |||||
CVE-2024-39875 | 1 Siemens | 1 Sinema Remote Connect Server | 2024-08-07 | N/A | 4.3 MEDIUM |
A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.2 SP1). The affected application allows authenticated, low privilege users with the 'Manage own remote connections' permission to retrieve details about other users and group memberships. | |||||
CVE-2024-35208 | 1 Siemens | 1 Sinec Traffic Analyzer | 2024-08-06 | N/A | 5.5 MEDIUM |
A vulnerability has been identified in SINEC Traffic Analyzer (6GK8822-1BG01-0BA0) (All versions < V1.2). The affected web server stored the password in cleartext. This could allow attacker in a privileged position to obtain access passwords. | |||||
CVE-2024-35207 | 1 Siemens | 1 Sinec Traffic Analyzer | 2024-08-06 | N/A | 7.8 HIGH |
A vulnerability has been identified in SINEC Traffic Analyzer (6GK8822-1BG01-0BA0) (All versions < V1.2). The web interface of the affected devices are vulnerable to Cross-Site Request Forgery(CSRF) attacks. By tricking an authenticated victim user to click a malicious link, an attacker could perform arbitrary actions on the device on behalf of the victim user. | |||||
CVE-2016-20009 | 2 Siemens, Windriver | 15 Sgt-100, Sgt-100 Firmware, Sgt-200 and 12 more | 2024-08-06 | 7.5 HIGH | 9.8 CRITICAL |
A DNS client stack-based buffer overflow in ipdnsc_decode_name() affects Wind River VxWorks 6.5 through 7. NOTE: This vulnerability only affects products that are no longer supported by the maintainer | |||||
CVE-2021-33627 | 2 Insyde, Siemens | 29 Insydeh2o, Simatic Field Pg M5, Simatic Field Pg M5 Firmware and 26 more | 2024-07-22 | 7.2 HIGH | 8.2 HIGH |
An issue was discovered in Insyde InsydeH2O Kernel 5.0 before 05.09.11, 5.1 before 05.17.11, 5.2 before 05.27.11, 5.3 before 05.36.11, 5.4 before 05.44.11, and 5.5 before 05.52.11 affecting FwBlockServiceSmm. Software SMI services that use the Communicate() function of the EFI_SMM_COMMUNICATION_PROTOCOL do not check whether the address of the buffer is valid, which allows use of SMRAM, MMIO, or OS kernel addresses. |