Vulnerabilities (CVE)

Filtered by vendor Tenda Subscribe
Total 1328 CVE
CVE Vendors Products Updated CVSS v2 CVSS v3
CVE-2022-45515 1 Tenda 2 W30e, W30e Firmware 2025-04-23 N/A 7.5 HIGH
Tenda W30E V1.0.1.25(633) was discovered to contain a stack overflow via the entries parameter at /goform/addressNat.
CVE-2022-45523 1 Tenda 2 W30e, W30e Firmware 2025-04-23 N/A 7.5 HIGH
Tenda W30E V1.0.1.25(633) was discovered to contain a stack overflow via the page parameter at /goform/L7Im.
CVE-2022-45504 1 Tenda 2 W6-s, W6-s Firmware 2025-04-23 N/A 7.5 HIGH
An issue in the component tpi_systool_handle(0) (/goform/SysToolRestoreSet) of Tenda W6-S v1.0.0.4(510) allows unauthenticated attackers to arbitrarily reboot the device.
CVE-2022-45518 1 Tenda 2 W30e, W30e Firmware 2025-04-23 N/A 7.5 HIGH
Tenda W30E V1.0.1.25(633) was discovered to contain a stack overflow via the page parameter at /goform/SetIpBind.
CVE-2022-45505 1 Tenda 2 W30e, W30e Firmware 2025-04-23 N/A 7.5 HIGH
Tenda W30E V1.0.1.25(633) was discovered to contain a stack overflow via the cmdinput parameter at /goform/exeCommand.
CVE-2022-45503 1 Tenda 2 W6-s, W6-s Firmware 2025-04-23 N/A 7.5 HIGH
Tenda W6-S v1.0.0.4(510) was discovered to contain a stack overflow via the linkEn parameter at /goform/setAutoPing.
CVE-2022-45511 1 Tenda 2 W30e, W30e Firmware 2025-04-23 N/A 7.5 HIGH
Tenda W30E V1.0.1.25(633) was discovered to contain a stack overflow via the PPPOEPassword parameter at /goform/QuickIndex.
CVE-2022-45667 1 Tenda 2 I22, I22 Firmware 2025-04-23 N/A 6.5 MEDIUM
Tenda i22 V1.0.0.3(4687) is vulnerable to Cross Site Request Forgery (CSRF) via function fromSysToolRestoreSet.
CVE-2022-45512 1 Tenda 2 W30e, W30e Firmware 2025-04-23 N/A 7.5 HIGH
Tenda W30E V1.0.1.25(633) was discovered to contain a stack overflow via the page parameter at /goform/SafeEmailFilter.
CVE-2022-45506 1 Tenda 2 W30e, W30e Firmware 2025-04-23 N/A 9.8 CRITICAL
Tenda W30E v1.0.1.25(633) was discovered to contain a command injection vulnerability via the fileNameMit parameter at /goform/delFileName.
CVE-2022-45520 1 Tenda 2 W30e, W30e Firmware 2025-04-23 N/A 7.5 HIGH
Tenda W30E V1.0.1.25(633) was discovered to contain a stack overflow via the page parameter at /goform/qossetting.
CVE-2022-45517 1 Tenda 2 W30e, W30e Firmware 2025-04-23 N/A 7.5 HIGH
Tenda W30E V1.0.1.25(633) was discovered to contain a stack overflow via the page parameter at /goform/VirtualSer.
CVE-2022-45501 1 Tenda 2 W6-s, W6-s Firmware 2025-04-23 N/A 7.5 HIGH
Tenda W6-S v1.0.0.4(510) was discovered to contain a stack overflow via the wl_radio parameter at /goform/wifiSSIDset.
CVE-2022-45514 1 Tenda 2 W30e, W30e Firmware 2025-04-23 N/A 7.5 HIGH
Tenda W30E V1.0.1.25(633) was discovered to contain a stack overflow via the page parameter at /goform/webExcptypemanFilter.
CVE-2022-45497 1 Tenda 2 W6-s, W6-s Firmware 2025-04-23 N/A 9.8 CRITICAL
Tenda W6-S v1.0.0.4(510) was discovered to contain a command injection vulnerability in the tpi_get_ping_output function at /goform/exeCommand.
CVE-2022-45516 1 Tenda 2 W30e, W30e Firmware 2025-04-23 N/A 7.5 HIGH
Tenda W30E V1.0.1.25(633) was discovered to contain a stack overflow via the page parameter at /goform/NatStaticSetting.
CVE-2022-45525 1 Tenda 2 W30e, W30e Firmware 2025-04-23 N/A 7.5 HIGH
Tenda W30E V1.0.1.25(633) was discovered to contain a stack overflow via the downaction parameter at /goform/CertListInfo.
CVE-2022-45507 1 Tenda 2 W30e, W30e Firmware 2025-04-23 N/A 7.5 HIGH
Tenda W30E V1.0.1.25(633) was discovered to contain a stack overflow via the editNameMit parameter at /goform/editFileName.
CVE-2022-45524 1 Tenda 2 W30e, W30e Firmware 2025-04-23 N/A 7.5 HIGH
Tenda W30E V1.0.1.25(633) was discovered to contain a stack overflow via the opttype parameter at /goform/IPSECsave.
CVE-2022-45499 1 Tenda 2 W6-s, W6-s Firmware 2025-04-23 N/A 7.5 HIGH
Tenda W6-S v1.0.0.4(510) was discovered to contain a stack overflow via the wl_radio parameter at /goform/WifiMacFilterGet.