Filtered by vendor Schneider-electric
Subscribe
Total
757 CVE
| CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
|---|---|---|---|---|---|
| CVE-2023-22611 | 1 Schneider-electric | 3 Ecostruxure Geo Scada Expert 2019, Ecostruxure Geo Scada Expert 2020, Ecostruxure Geo Scada Expert 2021 | 2023-02-07 | N/A | 7.5 HIGH |
| A CWE-200: Exposure of Sensitive Information to an Unauthorized Actor vulnerability exists that could cause information disclosure when specific messages are sent to the server over the database server TCP port. Affected Products: EcoStruxure Geo SCADA Expert 2019 - 2021 (formerly known as ClearSCADA) (Versions prior to October 2022) | |||||
| CVE-2022-32519 | 1 Schneider-electric | 1 Data Center Expert | 2023-02-07 | N/A | 9.8 CRITICAL |
| A CWE-257: Storing Passwords in a Recoverable Format vulnerability exists that could result in unwanted access to a DCE instance when performed over a network by a malicious third-party. Affected Products: Data Center Expert (Versions prior to V7.9.0) | |||||
| CVE-2022-32518 | 1 Schneider-electric | 1 Data Center Expert | 2023-02-07 | N/A | 9.8 CRITICAL |
| A CWE-522: Insufficiently Protected Credentials vulnerability exists that could result in unwanted access to a DCE instance when performed over a network by a malicious third-party. This CVE is unique from CVE-2022-32520. Affected Products: Data Center Expert (Versions prior to V7.9.0) | |||||
| CVE-2022-32520 | 1 Schneider-electric | 1 Data Center Expert | 2023-02-07 | N/A | 9.8 CRITICAL |
| A CWE-522: Insufficiently Protected Credentials vulnerability exists that could result in unwanted access to a DCE instance when performed over a network by a malicious third-party. This CVE is unique from CVE-2022-32518. Affected Products: Data Center Expert (Versions prior to V7.9.0) | |||||
| CVE-2022-32517 | 1 Schneider-electric | 2 Conext Combox, Conext Combox Firmware | 2023-02-07 | N/A | 6.5 MEDIUM |
| A CWE-1021: Improper Restriction of Rendered UI Layers or Frames vulnerability exists that could cause an adversary to trick the interface user/admin into interacting with the application in an unintended way when the product does not implement restrictions on the ability to render within frames on external addresses. Affected Products: Conext™ ComBox (All Versions) | |||||
| CVE-2022-32515 | 1 Schneider-electric | 2 Conext Combox, Conext Combox Firmware | 2023-02-07 | N/A | 9.8 CRITICAL |
| A CWE-307: Improper Restriction of Excessive Authentication Attempts vulnerability exists that could cause brute force attacks to take over the admin account when the product does not implement a rate limit mechanism on the admin authentication form. Affected Products: Conext™ ComBox (All Versions) | |||||
| CVE-2022-32516 | 1 Schneider-electric | 2 Conext Combox, Conext Combox Firmware | 2023-02-07 | N/A | 6.5 MEDIUM |
| A CWE-352: Cross-Site Request Forgery (CSRF) vulnerability exists that could cause system’s configurations override and cause a reboot loop when the product suffers from POST-Based Cross-Site Request Forgery (CSRF). Affected Products: Conext™ ComBox (All Versions) | |||||
| CVE-2022-2988 | 1 Schneider-electric | 2 Ecostruxure Machine Expert - Hvac, Somachine Hvac | 2023-02-07 | N/A | 7.5 HIGH |
| A CWE-787: Out-of-bounds Write vulnerability exists that could cause sensitive information leakage when accessing a malicious web page from the commissioning software. Affected Products: SoMachine HVAC (Versions prior to V2.1.0), EcoStruxure Machine Expert – HVAC (Versions prior to V1.4.0) | |||||
| CVE-2022-32512 | 1 Schneider-electric | 1 Canbrass | 2023-02-07 | N/A | 7.8 HIGH |
| A CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists that could cause remote code execution when a command which exploits this vulnerability is utilized. Affected Products: CanBRASS (Versions prior to V7.5.1) | |||||
| CVE-2022-22732 | 1 Schneider-electric | 1 Ecostruxure Power Commission | 2023-02-07 | N/A | 7.5 HIGH |
| A CWE-668: Exposure of Resource to Wrong Sphere vulnerability exists that could cause all remote domains to access the resources (data) supplied by the server when an attacker sends a fetch request from third-party site or malicious site. Affected Products: EcoStruxure Power Commission (Versions prior to V2.22) | |||||
| CVE-2022-22731 | 1 Schneider-electric | 1 Ecostruxure Power Commission | 2023-02-07 | N/A | 9.8 CRITICAL |
| A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists in a function that could allow an attacker to create or overwrite critical files that are used to execute code, such as programs or libraries and cause path traversal attacks. Affected Products: EcoStruxure Power Commission (Versions prior to V2.22) | |||||
| CVE-2022-0223 | 1 Schneider-electric | 1 Ecostruxure Power Commission | 2023-02-07 | N/A | 9.8 CRITICAL |
| A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists that could allow an attacker to create or overwrite critical files that are used to execute code, such as programs or libraries and cause unauthenticated code execution. Affected Products: EcoStruxure Power Commission (Versions prior to V2.22) | |||||
| CVE-2022-22808 | 1 Schneider-electric | 14 Hmibscea53d1edb, Hmibscea53d1edb Firmware, Hmibscea53d1edl and 11 more | 2023-02-02 | 6.8 MEDIUM | 8.8 HIGH |
| A CWE-352: Cross-Site Request Forgery (CSRF) exists that could cause a remote attacker to gain unauthorized access to the product when conducting cross-domain attacks based on same-origin policy or cross-site request forgery protections bypass. Affected Product: EcoStruxure EV Charging Expert (formerly known as EVlink Load Management System): (HMIBSCEA53D1EDB, HMIBSCEA53D1EDS, HMIBSCEA53D1EDM, HMIBSCEA53D1EDL, HMIBSCEA53D1ESS, HMIBSCEA53D1ESM, HMIBSCEA53D1EML) (All Versions prior to SP8 (Version 01) V4.0.0.13) | |||||
| CVE-2017-9629 | 1 Schneider-electric | 1 Wonderware Archestra Logger | 2023-02-02 | 10.0 HIGH | 9.8 CRITICAL |
| A Stack-Based Buffer Overflow issue was discovered in Schneider Electric Wonderware ArchestrA Logger, versions 2017.426.2307.1 and prior. The stack-based buffer overflow vulnerability has been identified, which may allow a remote attacker to execute arbitrary code in the context of a highly privileged account. | |||||
| CVE-2017-9631 | 1 Schneider-electric | 1 Wonderware Archestra Logger | 2023-02-01 | 5.0 MEDIUM | 7.5 HIGH |
| A Null Pointer Dereference issue was discovered in Schneider Electric Wonderware ArchestrA Logger, versions 2017.426.2307.1 and prior. The null pointer dereference vulnerability could allow an attacker to crash the logger process, causing a denial of service for logging and log-viewing (applications that use the Wonderware ArchestrA Logger continue to run when the Wonderware ArchestrA Logger service is unavailable). | |||||
| CVE-2017-9627 | 1 Schneider-electric | 1 Wonderware Archestra Logger | 2023-02-01 | 5.0 MEDIUM | 8.6 HIGH |
| An Uncontrolled Resource Consumption issue was discovered in Schneider Electric Wonderware ArchestrA Logger, versions 2017.426.2307.1 and prior. The uncontrolled resource consumption vulnerability could allow an attacker to exhaust the memory resources of the machine, causing a denial of service. | |||||
| CVE-2018-7801 | 1 Schneider-electric | 2 Evlink Parking, Evlink Parking Firmware | 2023-02-01 | 6.8 MEDIUM | 8.8 HIGH |
| A Code Injection vulnerability exists in EVLink Parking, v3.2.0-12_v1 and earlier, which could enable access with maximum privileges when a remote code execution is performed. | |||||
| CVE-2021-22737 | 1 Schneider-electric | 4 Homelynk, Homelynk Firmware, Spacelynk and 1 more | 2023-01-20 | 5.0 MEDIUM | 9.8 CRITICAL |
| Insufficiently Protected Credentials vulnerability exists in homeLYnk (Wiser For KNX) and spaceLYnk V2.60 and prior that could cause unauthorized access of when credentials are discovered after a brute force attack. | |||||
| CVE-2020-7561 | 1 Schneider-electric | 2 Easergy T300, Easergy T300 Firmware | 2022-12-12 | 7.5 HIGH | 9.8 CRITICAL |
| A CWE-306: Missing Authentication for Critical Function vulnerability exists in Easergy T300 (with firmware 2.7 and older) that could cause a wide range of problems, including information exposure, denial of service, and command execution when access to a resource from an attacker is not restricted or incorrectly restricted. | |||||
| CVE-2019-6811 | 1 Schneider-electric | 4 Modicon Quantum 140noe77101, Modicon Quantum 140noe77101 Firmware, Modicon Quantum 140noe77111 and 1 more | 2022-11-30 | 5.0 MEDIUM | 7.5 HIGH |
| An Improper Check for Unusual or Exceptional Conditions (CWE-754) vulnerability exists in Modicon Quantum 140 NOE771x1 version 6.9 and earlier, which could cause denial of service when the module receives an IP fragmented packet with a length greater than 65535 bytes. The module then requires a power cycle to recover. | |||||