Total
11736 CVE
CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
---|---|---|---|---|---|
CVE-2021-44335 | 1 Ok-file-formats Project | 1 Ok-file-formats | 2022-03-14 | 6.8 MEDIUM | 7.8 HIGH |
David Brackeen ok-file-formats 203defd is vulnerable to Buffer Overflow. When the function of the ok-file-formats project is used, a heap-buffer-overflow occurs in function ok_png_transform_scanline() in "/ok_png.c:533". | |||||
CVE-2021-40064 | 1 Huawei | 3 Emui, Harmonyos, Magic Ui | 2022-03-14 | 7.8 HIGH | 7.5 HIGH |
There is a heap-based buffer overflow vulnerability in system components. Successful exploitation of this vulnerability may affect system stability. | |||||
CVE-2021-40060 | 1 Huawei | 2 Emui, Magic Ui | 2022-03-14 | 7.8 HIGH | 7.5 HIGH |
There is a heap-based buffer overflow vulnerability in the video framework. Successful exploitation of this vulnerability may affect availability. | |||||
CVE-2021-40058 | 1 Huawei | 2 Emui, Magic Ui | 2022-03-14 | 7.8 HIGH | 7.5 HIGH |
There is a heap-based buffer overflow vulnerability in the video framework. Successful exploitation of this vulnerability may affect availability. | |||||
CVE-2021-40057 | 1 Huawei | 2 Emui, Magic Ui | 2022-03-14 | 7.8 HIGH | 7.5 HIGH |
There is a heap-based and stack-based buffer overflow vulnerability in the video framework. Successful exploitation of this vulnerability may affect availability. | |||||
CVE-2022-25547 | 1 Tenda | 2 Ax1806, Ax1806 Firmware | 2022-03-12 | 7.8 HIGH | 7.5 HIGH |
Tenda AX1806 v1.0.0.1 was discovered to contain a stack overflow in the function fromSetSysTime. This vulnerability allows attackers to cause a Denial of Service (DoS) via the time parameter. | |||||
CVE-2022-25549 | 1 Tenda | 2 Ax1806, Ax1806 Firmware | 2022-03-12 | 7.8 HIGH | 7.5 HIGH |
Tenda AX1806 v1.0.0.1 was discovered to contain a stack overflow in the function formSetSysToolDDNS. This vulnerability allows attackers to cause a Denial of Service (DoS) via the ddnsEn parameter. | |||||
CVE-2022-25555 | 1 Tenda | 2 Ax1806, Ax1806 Firmware | 2022-03-12 | 7.8 HIGH | 7.5 HIGH |
Tenda AX1806 v1.0.0.1 was discovered to contain a stack overflow in the function fromSetSysTime. This vulnerability allows attackers to cause a Denial of Service (DoS) via the ntpServer parameter. | |||||
CVE-2022-25566 | 1 Tenda | 2 Ax1806, Ax1806 Firmware | 2022-03-12 | 7.8 HIGH | 7.5 HIGH |
Tenda AX1806 v1.0.0.1 was discovered to contain a stack overflow in the function saveParentControlInfo. This vulnerability allows attackers to cause a Denial of Service (DoS) via the time parameter. | |||||
CVE-2022-25557 | 1 Tenda | 2 Ax1806, Ax1806 Firmware | 2022-03-12 | 7.8 HIGH | 7.5 HIGH |
Tenda AX1806 v1.0.0.1 was discovered to contain a heap overflow in the function saveParentControlInfo. This vulnerability allows attackers to cause a Denial of Service (DoS) via the urls parameter. | |||||
CVE-2022-25558 | 1 Tenda | 2 Ax1806, Ax1806 Firmware | 2022-03-12 | 7.8 HIGH | 7.5 HIGH |
Tenda AX1806 v1.0.0.1 was discovered to contain a stack overflow in the function formSetProvince. This vulnerability allows attackers to cause a Denial of Service (DoS) via the ProvinceCode parameter. | |||||
CVE-2022-25553 | 1 Tenda | 2 Ax1806, Ax1806 Firmware | 2022-03-12 | 7.8 HIGH | 7.5 HIGH |
Tenda AX1806 v1.0.0.1 was discovered to contain a stack overflow in the function formSetSysToolDDNS. This vulnerability allows attackers to cause a Denial of Service (DoS) via the ddnsPwd parameter. | |||||
CVE-2022-25552 | 1 Tenda | 2 Ax1806, Ax1806 Firmware | 2022-03-12 | 7.8 HIGH | 7.5 HIGH |
Tenda AX1806 v1.0.0.1 was discovered to contain a stack overflow in the function form_fast_setting_wifi_set. This vulnerability allows attackers to cause a Denial of Service (DoS) via the ssid parameter. | |||||
CVE-2022-25554 | 1 Tenda | 2 Ax1806, Ax1806 Firmware | 2022-03-12 | 7.8 HIGH | 7.5 HIGH |
Tenda AX1806 v1.0.0.1 was discovered to contain a stack overflow in the function saveParentControlInfo. This vulnerability allows attackers to cause a Denial of Service (DoS) via the deviceId parameter. | |||||
CVE-2022-25546 | 1 Tenda | 2 Ax1806, Ax1806 Firmware | 2022-03-12 | 7.8 HIGH | 7.5 HIGH |
Tenda AX1806 v1.0.0.1 was discovered to contain a stack overflow in the function formSetSysToolDDNS. This vulnerability allows attackers to cause a Denial of Service (DoS) via the ddnsUser parameter. | |||||
CVE-2022-25550 | 1 Tenda | 2 Ax1806, Ax1806 Firmware | 2022-03-12 | 7.8 HIGH | 7.5 HIGH |
Tenda AX1806 v1.0.0.1 was discovered to contain a stack overflow in the function saveParentControlInfo. This vulnerability allows attackers to cause a Denial of Service (DoS) via the deviceName parameter. | |||||
CVE-2022-25548 | 1 Tenda | 2 Ax1806, Ax1806 Firmware | 2022-03-12 | 7.8 HIGH | 7.5 HIGH |
Tenda AX1806 v1.0.0.1 was discovered to contain a stack overflow in the function fromSetSysTime. This vulnerability allows attackers to cause a Denial of Service (DoS) via the serverName parameter. | |||||
CVE-2022-25551 | 1 Tenda | 2 Ax1806, Ax1806 Firmware | 2022-03-12 | 7.8 HIGH | 7.5 HIGH |
Tenda AX1806 v1.0.0.1 was discovered to contain a stack overflow in the function formSetSysToolDDNS. This vulnerability allows attackers to cause a Denial of Service (DoS) via the ddnsDomain parameter. | |||||
CVE-2022-25106 | 1 Dlink | 4 Dir-859, Dir-859 A3, Dir-859 A3 Firmware and 1 more | 2022-03-12 | 7.1 HIGH | 5.5 MEDIUM |
D-Link DIR-859 v1.05 was discovered to contain a stack-based buffer overflow via the function genacgi_main. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted payload. | |||||
CVE-2022-24661 | 1 Siemens | 1 Simcenter Star-ccm\+ Viewer | 2022-03-11 | 6.8 MEDIUM | 7.8 HIGH |
A vulnerability has been identified in Simcenter STAR-CCM+ Viewer (All versions < V2022.1). The starview+.exe contains a memory corruption vulnerability while parsing specially crafted .SCE files. This could allow an attacker to execute code in the context of the current process. |