Total
1788 CVE
CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
---|---|---|---|---|---|
CVE-2020-36451 | 1 Rcu Cell Project | 1 Rcu Cell | 2021-08-16 | 6.8 MEDIUM | 8.1 HIGH |
An issue was discovered in the rcu_cell crate through 2020-11-14 for Rust. There are unconditional implementations of Send and Sync for RcuCell<T>. | |||||
CVE-2020-36450 | 1 Bunch Project | 1 Bunch | 2021-08-16 | 6.8 MEDIUM | 8.1 HIGH |
An issue was discovered in the bunch crate through 2020-11-12 for Rust. There are unconditional implementations of Send and Sync for Bunch<T>. | |||||
CVE-2020-36449 | 1 Kekbit Project | 1 Kekbit | 2021-08-16 | 6.8 MEDIUM | 8.1 HIGH |
An issue was discovered in the kekbit crate before 0.3.4 for Rust. For ShmWriter<H>, Send is implemented without requiring H: Send. | |||||
CVE-2020-36448 | 1 Cache Project | 1 Cache | 2021-08-16 | 6.8 MEDIUM | 8.1 HIGH |
An issue was discovered in the cache crate through 2020-11-24 for Rust. There are unconditional implementations of Send and Sync for Cache<K>. | |||||
CVE-2021-38169 | 1 Roxy-wi | 1 Roxy-wi | 2021-08-13 | 6.5 MEDIUM | 8.8 HIGH |
Roxy-WI through 5.2.2.0 allows command injection via /app/funct.py and /api/api_funct.py. | |||||
CVE-2021-36707 | 1 Prolink | 2 Prc2402m, Prc2402m Firmware | 2021-08-12 | 7.5 HIGH | 9.8 CRITICAL |
In ProLink PRC2402M V1.0.18 and older, the set_ledonoff function in the adm.cgi binary, accessible with a page parameter value of ledonoff contains a trivial command injection where the value of the led_cmd parameter is passed directly to do_system. | |||||
CVE-2021-21406 | 1 Combodo | 1 Itop | 2021-07-30 | 6.5 MEDIUM | 8.8 HIGH |
Combodo iTop is an open source, web based IT Service Management tool. In versions prior to 2.7.4, there is a command injection vulnerability in the Setup Wizard when providing Graphviz executable path. The vulnerability is patched in version 2.7.4 and 3.0.0. | |||||
CVE-2020-3924 | 1 Tonnet | 16 Tat-70432n, Tat-70432n Firmware, Tat-71416g1 and 13 more | 2021-07-21 | 10.0 HIGH | 9.8 CRITICAL |
DVR firmware in TAT-76 and TAT-77 series of products, provided by TONNET do not properly verify patch files. Attackers can inject a specific command into a patch file and gain access to the system. | |||||
CVE-2020-5601 | 1 Nta | 1 E-tax Reception System | 2021-07-21 | 6.8 MEDIUM | 8.8 HIGH |
Chrome Extension for e-Tax Reception System Ver1.0.0.0 allows remote attackers to execute an arbitrary command via unspecified vectors. | |||||
CVE-2019-20706 | 1 Netgear | 4 R7800, R7800 Firmware, Xr500 and 1 more | 2021-07-21 | 5.2 MEDIUM | 8.0 HIGH |
Certain NETGEAR devices are affected by command injection by an authenticated user. This affects R7800 before 1.0.2.60 and XR500 before 2.3.2.32. | |||||
CVE-2020-14441 | 1 Netgear | 24 Rbk752, Rbk752 Firmware, Rbk753 and 21 more | 2021-07-21 | 5.8 MEDIUM | 8.8 HIGH |
Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK842 before 3.2.15.25, RBR840 before 3.2.15.25, RBS840 before 3.2.15.25, RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBR850 before 3.2.15.25, and RBS850 before 3.2.15.25. | |||||
CVE-2020-0130 | 1 Google | 1 Android | 2021-07-21 | 4.6 MEDIUM | 7.8 HIGH |
In screencap, there is a possible command injection due to improper input validation. This could lead to local escalation of privilege in a system process with User execution privileges needed. User interaction is not needed for exploitation.Product: AndroidVersions: Android-11Android ID: A-123230379 | |||||
CVE-2020-13917 | 1 Ruckuswireless | 25 C110, E510, H320 and 22 more | 2021-07-21 | 7.5 HIGH | 9.8 CRITICAL |
rkscli in Ruckus Wireless Unleashed through 200.7.10.92 allows a remote attacker to achieve command injection and jailbreak the CLI via a crafted CLI command. This affects C110, E510, H320, H510, M510, R320, R310, R500, R510 R600, R610, R710, R720, R750, T300, T301n, T301s, T310c, T310d, T310n, T310s, T610, T710, and T710s devices. | |||||
CVE-2020-11496 | 1 Sprecher-automation | 1 Sprecon-e | 2021-07-21 | 7.2 HIGH | 6.7 MEDIUM |
Sprecher SPRECON-E firmware prior to 8.64b might allow local attackers with access to engineering data to insert arbitrary code. This firmware lacks the validation of the input values on the device side, which is provided by the engineering software during parameterization. Attackers with access to local configuration files can therefore insert malicious commands that are executed after compiling them to valid parameter files (“PDLs”), transferring them to the device, and restarting the device. | |||||
CVE-2019-20703 | 1 Netgear | 6 D3600, D3600 Firmware, D6000 and 3 more | 2021-07-21 | 5.2 MEDIUM | 8.0 HIGH |
Certain NETGEAR devices are affected by command injection by an authenticated user. This affects D3600 before 1.0.0.76, D6000 before 1.0.0.76, and XR500 before 2.3.2.32. | |||||
CVE-2020-14100 | 1 Mi | 2 R3600, R3600 Firmware | 2021-07-21 | 10.0 HIGH | 9.8 CRITICAL |
In Xiaomi router R3600 ROM version<1.0.66, filters in the set_WAN6 interface can be bypassed, causing remote code execution. The router administrator can gain root access from this vulnerability. | |||||
CVE-2020-14436 | 1 Netgear | 24 Rbk752, Rbk752 Firmware, Rbk753 and 21 more | 2021-07-21 | 5.8 MEDIUM | 8.8 HIGH |
Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBR850 before 3.2.15.25, RBS850 before 3.2.15.25, RBK842 before 3.2.15.25, RBR840 before 3.2.15.25, and RBS840 before 3.2.15.25. | |||||
CVE-2020-1790 | 1 Huawei | 1 Gaussdb 200 | 2021-07-21 | 6.5 MEDIUM | 8.8 HIGH |
GaussDB 200 with version of 6.5.1 have a command injection vulnerability. The software constructs part of a command using external input from users, but the software does not sufficiently validate the user input. Successful exploit could allow the attacker to inject certain commands. | |||||
CVE-2020-14437 | 1 Netgear | 24 Rbk752, Rbk752 Firmware, Rbk753 and 21 more | 2021-07-21 | 5.8 MEDIUM | 8.8 HIGH |
Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK842 before 3.2.15.25, RBR840 before 3.2.15.25, RBS840 before 3.2.15.25, RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBR850 before 3.2.15.25, and RBS850 before 3.2.15.25. | |||||
CVE-2020-9578 | 1 Magento | 1 Magento | 2021-07-21 | 7.5 HIGH | 9.8 CRITICAL |
Magento versions 2.3.4 and earlier, 2.2.11 and earlier (see note), 1.14.4.4 and earlier, and 1.9.4.4 and earlier have a command injection vulnerability. Successful exploitation could lead to arbitrary code execution. |