Total
1255 CVE
CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
---|---|---|---|---|---|
CVE-2018-15645 | 1 Odoo | 1 Odoo | 2020-12-23 | 4.0 MEDIUM | 6.5 MEDIUM |
Improper access control in message routing in Odoo Community 12.0 and earlier and Odoo Enterprise 12.0 and earlier allows remote authenticated users to create arbitrary records via crafted payloads, which may allow privilege escalation. | |||||
CVE-2020-25191 | 1 Ni | 2 Compactrio, Compactrio Firmware | 2020-12-14 | 7.8 HIGH | 7.5 HIGH |
Incorrect permissions are set by default for an API entry-point of a specific service, allowing a non-authenticated user to trigger a function that could reboot the CompactRIO (Driver versions prior to 20.5) remotely. | |||||
CVE-2017-11422 | 1 Statamic | 1 Statamic | 2020-12-10 | 6.5 MEDIUM | 8.8 HIGH |
Statamic framework before 2.6.0 does not correctly check a session's permissions when the methods from a user's class are called. Problematic methods include reset password, create new account, create new role, etc. | |||||
CVE-2020-28055 | 1 Tcl | 14 32s330, 32s330 Firmware, 40s330 and 11 more | 2020-12-08 | 7.2 HIGH | 7.8 HIGH |
A vulnerability in the TCL Android Smart TV series V8-R851T02-LF1 V295 and below and V8-T658T01-LF1 V373 and below by TCL Technology Group Corporation allows a local unprivileged attacker, such as a malicious App, to read & write to the /data/vendor/tcl, /data/vendor/upgrade, and /var/TerminalManager directories within the TV file system. An attacker, such as a malicious APK or local unprivileged user could perform fake system upgrades by writing to the /data/vendor/upgrage folder. | |||||
CVE-2020-11831 | 1 Oppo | 1 Ovoicemanager | 2020-12-04 | 10.0 HIGH | 9.8 CRITICAL |
OvoiceManager has system permission to write vulnerability reports for arbitrary files, affected product is com.oppo.ovoicemanager V2.0.1. | |||||
CVE-2020-28914 | 1 Katacontainers | 1 Kata-containers | 2020-12-04 | 3.6 LOW | 7.1 HIGH |
An improper file permissions vulnerability affects Kata Containers prior to 1.11.5. When using a Kubernetes hostPath volume and mounting either a file or directory into a container as readonly, the file/directory is mounted as readOnly inside the container, but is still writable inside the guest. For a container breakout situation, a malicious guest can potentially modify or delete files/directories expected to be read-only. | |||||
CVE-2019-11121 | 2 Intel, Microsoft | 2 Media Sdk, Windows | 2020-11-19 | 4.6 MEDIUM | 7.8 HIGH |
Improper file permissions in the installer for the Intel(R) Media SDK for Windows before version 2019 R1 may allow an authenticated user to potentially enable escalation of privilege via local access. | |||||
CVE-2020-27658 | 1 Synology | 1 Router Manager | 2020-11-03 | 4.3 MEDIUM | 6.1 MEDIUM |
Synology Router Manager (SRM) before 1.2.4-8081 does not include the HTTPOnly flag in a Set-Cookie header for the session cookie, which makes it easier for remote attackers to obtain potentially sensitive information via script access to this cookie. | |||||
CVE-2020-15910 | 1 Solarwinds | 1 N-central | 2020-10-29 | 4.3 MEDIUM | 4.7 MEDIUM |
SolarWinds N-Central version 12.3 GA and lower does not set the JSESSIONID attribute to HTTPOnly. This makes it possible to influence the cookie with javascript. An attacker could send the user to a prepared webpage or by influencing JavaScript to the extract the JESSIONID. This could then be forwarded to the attacker. | |||||
CVE-2017-1459 | 1 Ibm | 5 Security Access Manager 9.0 Firmware, Security Access Manager For Mobile, Security Access Manager For Mobile Appliance and 2 more | 2020-10-27 | 4.9 MEDIUM | 4.2 MEDIUM |
IBM Security Access Manager Appliance 8.0.0 and 9.0.0 specifies permissions for a security-critical resource in a way that allows that resource to be read or modified by unintended actors. IBM X-Force ID: 128378. | |||||
CVE-2017-7493 | 2 Debian, Qemu | 2 Debian Linux, Qemu | 2020-10-23 | 4.6 MEDIUM | 7.8 HIGH |
Quick Emulator (Qemu) built with the VirtFS, host directory sharing via Plan 9 File System(9pfs) support, is vulnerable to an improper access control issue. It could occur while accessing virtfs metadata files in mapped-file security mode. A guest user could use this flaw to escalate their privileges inside guest. | |||||
CVE-2020-10140 | 1 Acronis | 1 True Image | 2020-10-22 | 6.9 MEDIUM | 7.3 HIGH |
Acronis True Image 2021 fails to properly set ACLs of the C:\ProgramData\Acronis directory. Because some privileged processes are executed from the C:\ProgramData\Acronis, an unprivileged user can achieve arbitrary code execution with SYSTEM privileges by placing a DLL in one of several paths within C:\ProgramData\Acronis. | |||||
CVE-2019-3683 | 2 Hp, Suse | 3 Helion Openstack, Keystone-json-assignment, Openstack Cloud | 2020-10-22 | 6.5 MEDIUM | 8.8 HIGH |
The keystone-json-assignment package in SUSE Openstack Cloud 8 before commit d7888c75505465490250c00cc0ef4bb1af662f9f every user listed in the /etc/keystone/user-project-map.json was assigned full "member" role access to every project. This allowed these users to access, modify, create and delete arbitrary resources, contrary to expectations. | |||||
CVE-2019-1944 | 1 Cisco | 1 Adaptive Security Appliance Software | 2020-10-16 | 4.4 MEDIUM | 7.3 HIGH |
Multiple vulnerabilities in the smart tunnel functionality of Cisco Adaptive Security Appliance (ASA) could allow an authenticated, local attacker to elevate privileges to the root user or load a malicious library file while the tunnel is being established. For more information about these vulnerabilities, see the Details section of this security advisory. | |||||
CVE-2020-17414 | 2 Foxitsoftware, Microsoft | 3 Foxit Reader, Phantompdf, Windows | 2020-10-15 | 7.2 HIGH | 7.8 HIGH |
This vulnerability allows local attackers to escalate privileges on affected installations of Foxit Reader 10.0.0.35798. An attacker must first obtain the ability to execute low-privileged code on the target system in order to exploit this vulnerability. The specific flaw exists within the handling of the configuration files used by the Foxit Reader Update Service. The issue results from incorrect permissions set on a resource used by the service. An attacker can leverage this vulnerability to escalate privileges and execute code in the context of SYSTEM. Was ZDI-CAN-11229. | |||||
CVE-2020-17415 | 2 Foxitsoftware, Microsoft | 3 Foxit Reader, Phantompdf, Windows | 2020-10-15 | 7.2 HIGH | 7.8 HIGH |
This vulnerability allows local attackers to escalate privileges on affected installations of Foxit PhantomPDF 10.0.0.35798. An attacker must first obtain the ability to execute low-privileged code on the target system in order to exploit this vulnerability. The specific flaw exists within the handling of the configuration files used by the Foxit PhantomPDF Update Service. The issue results from incorrect permissions set on a resource used by the service. An attacker can leverage this vulnerability to escalate privileges and execute code in the context of SYSTEM. Was ZDI-CAN-11308. | |||||
CVE-2019-1803 | 1 Cisco | 22 Nexus 9000 Series Application Centric Infrastructure, Nexus 93108tc-ex, Nexus 93120tx and 19 more | 2020-10-13 | 7.2 HIGH | 6.7 MEDIUM |
A vulnerability in the filesystem management for the Cisco Nexus 9000 Series Application Centric Infrastructure (ACI) Mode Switch Software could allow an authenticated, local attacker with administrator rights to gain elevated privileges as the root user on an affected device. The vulnerability is due to overly permissive file permissions of specific system files. An attacker could exploit this vulnerability by authenticating to an affected device, creating a crafted command string, and writing this crafted string to a specific file location. A successful exploit could allow the attacker to execute arbitrary operating system commands as root on an affected device. The attacker would need to have valid administrator credentials for the device. | |||||
CVE-2020-17365 | 1 Pango | 1 Hotspot Shield | 2020-10-09 | 7.2 HIGH | 7.8 HIGH |
Improper directory permissions in the Hotspot Shield VPN client software for Windows 10.3.0 and earlier may allow an authorized user to potentially enable escalation of privilege via local access. The vulnerability allows a local user to corrupt system files: a local user can create a specially crafted symbolic link to a critical file on the system and overwrite it with privileges of the application. | |||||
CVE-2019-16784 | 2 Microsoft, Pyinstaller | 2 Windows, Pyinstaller | 2020-10-09 | 4.4 MEDIUM | 7.8 HIGH |
In PyInstaller before version 3.6, only on Windows, a local privilege escalation vulnerability is present in this particular case: If a software using PyInstaller in "onefile" mode is launched by a privileged user (at least more than the current one) which have his "TempPath" resolving to a world writable directory. This is the case for example if the software is launched as a service or as a scheduled task using a system account (TempPath will be C:\Windows\Temp). In order to be exploitable the software has to be (re)started after the attacker launch the exploit program, so for a service launched at startup, a service restart is needed (e.g. after a crash or an upgrade). | |||||
CVE-2019-1601 | 1 Cisco | 13 Mds 9000, Nexus 2000, Nexus 3000 and 10 more | 2020-10-08 | 7.2 HIGH | 7.8 HIGH |
A vulnerability in the filesystem permissions of Cisco NX-OS Software could allow an authenticated, local attacker to gain read and write access to a critical configuration file. The vulnerability is due to a failure to impose strict filesystem permissions on the targeted device. An attacker could exploit this vulnerability by accessing and modifying restricted files. A successful exploit could allow an attacker to use the content of this configuration file to bypass authentication and log in as any user of the device. MDS 9000 Series Multilayer Switches are affected in versions prior to 6.2(25), 8.1(1b), and 8.3(1). Nexus 3000 Series Switches are affected in versions prior to 7.0(3)I4(9) and 7.0(3)I7(4). Nexus 3500 Platform Switches are affected in versions prior to 6.0(2)A8(10) and 7.0(3)I7(4). Nexus 3600 Platform Switches are affected in versions prior to 7.0(3)F3(5). Nexus 2000, 5500, 5600, and 6000 Series Switches are affected in versions prior to 7.1(5)N1(1b) and 7.3(3)N1(1). Nexus 7000 and 7700 Series Switches are affected in versions prior to 6.2(22), 7.3(3)D1(1), and 8.2(3). Nexus 9000 Series Switches-Standalone are affected in versions prior to 7.0(3)I4(9) and 7.0(3)I7(4). Nexus 9500 R-Series Line Cards and Fabric Modules are affected in versions prior to 7.0(3)F3(5). |