CVE-2025-7544

A vulnerability was found in Tenda AC1206 15.03.06.23. It has been rated as critical. This issue affects the function formSetMacFilterCfg of the file /goform/setMacFilterCfg. The manipulation of the argument deviceList leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.
CVSS

No CVSS.

Configurations

Configuration 1 (hide)

AND
cpe:2.3:o:tenda:ac1206_firmware:15.03.06.23:*:*:*:*:*:*:*
cpe:2.3:h:tenda:ac1206:-:*:*:*:*:*:*:*

History

16 Jul 2025, 14:36

Type Values Removed Values Added
References () https://www.tenda.com.cn/ - () https://www.tenda.com.cn/ - Product
References () https://github.com/panda666-888/vuls/blob/main/tenda/ac1206/formSetMacFilterCfg.md - () https://github.com/panda666-888/vuls/blob/main/tenda/ac1206/formSetMacFilterCfg.md - Exploit, Third Party Advisory
References () https://vuldb.com/?ctiid.316241 - () https://vuldb.com/?ctiid.316241 - Permissions Required, VDB Entry
References () https://github.com/panda666-888/vuls/blob/main/tenda/ac1206/formSetMacFilterCfg.md#poc - () https://github.com/panda666-888/vuls/blob/main/tenda/ac1206/formSetMacFilterCfg.md#poc - Exploit, Third Party Advisory
References () https://vuldb.com/?submit.614089 - () https://vuldb.com/?submit.614089 - Third Party Advisory, VDB Entry
References () https://vuldb.com/?id.316241 - () https://vuldb.com/?id.316241 - Third Party Advisory, VDB Entry
First Time Tenda
Tenda ac1206
Tenda ac1206 Firmware
CPE cpe:2.3:o:tenda:ac1206_firmware:15.03.06.23:*:*:*:*:*:*:*
cpe:2.3:h:tenda:ac1206:-:*:*:*:*:*:*:*

15 Jul 2025, 20:15

Type Values Removed Values Added
CVSS v2 : unknown
v3 : 8.8
v2 : unknown
v3 : unknown
CWE CWE-121
CWE-119

13 Jul 2025, 22:15

Type Values Removed Values Added
New CVE

Information

Published : 2025-07-13 22:15

Updated : 2025-07-16 14:36


NVD link : CVE-2025-7544

Mitre link : CVE-2025-7544


JSON object : View

Products Affected

tenda

  • ac1206_firmware
  • ac1206
CWE

No CWE.