CVE-2025-1392

A vulnerability has been found in D-Link DIR-816 1.01TO and classified as problematic. Affected by this vulnerability is an unknown functionality of the file /cgi-bin/webproc?getpage=html/index.html&var:menu=24gwlan&var:page=24G_basic. The manipulation of the argument SSID leads to cross site scripting. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. This vulnerability only affects products that are no longer supported by the maintainer.
References
Link Resource
https://vuldb.com/?ctiid.296023 Permissions Required VDB Entry
https://vuldb.com/?id.296023 Third Party Advisory VDB Entry
https://vuldb.com/?submit.501351 Third Party Advisory VDB Entry
https://www.dlink.com/ Product
Configurations

Configuration 1 (hide)

AND
cpe:2.3:o:dlink:dir-816_firmware:1.01to:*:*:*:*:*:*:*
cpe:2.3:h:dlink:dir-816:-:*:*:*:*:*:*:*

History

16 Jul 2025, 14:26

Type Values Removed Values Added
CPE cpe:2.3:o:dlink:dir-816_firmware:1.01to:*:*:*:*:*:*:*
cpe:2.3:h:dlink:dir-816:-:*:*:*:*:*:*:*
References () https://vuldb.com/?id.296023 - () https://vuldb.com/?id.296023 - Third Party Advisory, VDB Entry
References () https://vuldb.com/?submit.501351 - () https://vuldb.com/?submit.501351 - Third Party Advisory, VDB Entry
References () https://vuldb.com/?ctiid.296023 - () https://vuldb.com/?ctiid.296023 - Permissions Required, VDB Entry
References () https://www.dlink.com/ - () https://www.dlink.com/ - Product
CVSS v2 : unknown
v3 : 3.5
v2 : unknown
v3 : 5.4
First Time Dlink dir-816
Dlink
Dlink dir-816 Firmware

17 Feb 2025, 16:15

Type Values Removed Values Added
New CVE

Information

Published : 2025-02-17 16:15

Updated : 2025-07-16 14:26


NVD link : CVE-2025-1392

Mitre link : CVE-2025-1392


JSON object : View

Products Affected

dlink

  • dir-816_firmware
  • dir-816
CWE
CWE-79

Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')

CWE-94

Improper Control of Generation of Code ('Code Injection')